• Title/Summary/Keyword: In-situ Calibration

Search Result 110, Processing Time 0.029 seconds

Database of virtual spectrum of artificial radionuclides for education and training in in-situ gamma spectrometry

  • Yoomi Choi;Young-Yong Ji;Sungyeop Joung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.190-200
    • /
    • 2023
  • As the field of application of in-situ gamma spectroscopy is diversified, proficiency is required for consistent and accurate analysis. In this study, a program was developed to virtually create gamma energy spectra of artificial nuclides, which are difficult to obtain through actual measurements, for training. The virtual spectrum was created by synthesizing the spectra of the background radiation obtained through actual measurement and the theoretical spectra of the artificial radionuclides obtained by a Monte Carlo simulation. Since the theoretical spectrum can only be obtained for a given geometrical structure, representative major geometries for in-situ measurement (ground surface, concrete wall, radioactive waste drum) and the detectors (HPGe, NaI(Tl), LaBr3(Ce)) were predetermined. Generated virtual spectra were verified in terms of validity and harmonization by gamma spectrometry and energy calibration. As a result, it was confirmed that the energy calibration results including the peaks of the measured spectrum and the peaks of the theoretical spectrum showed differences of less than 1 keV from the actual energies, and that the calculated radioactivity showed a difference within 20% from the actual inputted radioactivity. The verified data were assembled into a database and a program that can generate a virtual spectrum of desired condition was developed.

Calibration System for Three-Cup Anemometers (현장용 교정 장치를 이용한 3-컵 풍속계의 교정 방법)

  • Chun, Se-Jong;Lee, Saeng-Hee;Choi, Yong-Moon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.325-331
    • /
    • 2010
  • Three-cup anemometers are popular devices for measuring wind speeds in automated weather stations, environmental monitoring systems, and wind turbines. Cup anemometers usually suffer from lack of long-term stability owing to the wear of the bearing systems that support the rotational parts. The bearing systems are susceptible to external pollutants, vibrations, and gusts. Therefore, these anemometers have to be calibrated regularly to maintain the desired characteristics for measuring wind speed. In the present study, a new in-situ calibration system to help reduce cost and save time by calibrating the cup anemometers at the installation site is proposed. A portable in-situ calibrator was fabricated. After the characteristics of this calibrator were verified, it was used to calibrate cup anemometers. Some of the calibration results were compared with the data obtained by wind tunnel testing.

Development of Error Compensation Algorithm for Image based Measurement System (미세부품 영상 측정시 진동에 의한 오차 보상 알고리즘 개발)

  • Pyo Chang Ryul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.102-108
    • /
    • 2004
  • In this paper, we studied a vibration problem that is critical and common to most precision measurement systems. For micro mechanical part measurements, results obtained from the vision-based precision measurement system may contain errors due to the vibration. In order to defeat this generic problem, for the current study, a PC based image processing technique was used first, to assess the effect of the vibration to the precision measurement and second, to develop an in-situ calibration algorithm that automatically compensate the measurement results in real time. We used a set of stereoscopic CCD cameras to acquire the images for the dimensional measurement and the reference measurement. The mapping function was obtained through the in-situ calibration to compensate the measurement results and the statistical analysis for the actual results is provided in the paper. Based on the current statistical study, it is expected to obtain high precision results for the micro measurement systems.

Measurement Errors of Non-contact Type Vibration Sensors Used for Precision Measurement of Shaft Vibration (정밀 축진동 측정에 사용되는 비접촉식 진동센서의 측정오차)

  • 전오성;김동혁;최병천
    • Journal of KSNVE
    • /
    • v.1 no.2
    • /
    • pp.107-113
    • /
    • 1991
  • When non-contact type vibration probes are used for the precision measurement of shaft vibration, they can induce the measurement errors due to the shaft curvature since they have been calibrated for the flat plate. In this study the errors due to the shaft radius and the misalignment between the shaft and probe centerlines are analyzed, and an in-situ calibration tool, which can be conveniently used for calibration independent of the shaft curvature and material, is introduced.

  • PDF

Development of Frost Thickness Measurement Method Using Optical Technique (광학적 기법에 의한 Frost 두께 측정방법의 개발)

  • Jeong, Jae-Hong;Yoon, Sang-Youl;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.654-659
    • /
    • 2001
  • A new non-contact method of the frost thickness measurement has been developed. The method is based on the digital image processing technique to identify the reflection edge of the image captured by a CCD camera under laser sheet light illumination. To insure the accuracy of frost layer thickness, an in-situ calibration procedure is carried out with a calibration target with 0.5mm holes. Using the mapping function obtained by the calibration procedure, the contour of frost surface can be estimated with sub-pixel resolutions. The developed method is applied to study the effect of cooling plate temperature on the frost thickness in a small low speed wind tunnel.

  • PDF

Evaluation of In-situ Top Base Foundation Behavior using Calibration Chamber Test (모형토조실험을 통한 현장타설 팽이기초의 거동특성 연구)

  • Kim Hak-Moon;Kim Chan-Kuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.697-703
    • /
    • 2006
  • In this research, model tests for in-situ Top-Base Foundation are carried out in other to investigate the load delivering mechanism and the incremental effect of bearing capacity. According to the result of model tests, the load-settlement curves of both in-situ Top-Base(In-situ TBF) and Precast Top-Base Foundation(PC-TBF) showed similar results in term of the ground movement and effect of bearing capacity. Also, the range of vertical stresses delivered into ground was decreased with Top-Base method regarding other types foundations.

  • PDF

FIBER OPTIC SENSOR FOR IN-SITU AND REALTIME MONITORING OF TRANSPORT OF GAS PHASE OZONE IN UNSATURATED POROUS MEDIA

  • Jung, Hae-Ryong;Park, Hee-Chul
    • Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • A series of column experiments was conducted to develop a monitoring system for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone were obtained by converting the normalized intensity into ozone concentration. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of soil organic matter (SOM). However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

A ROCKET MEASUREMENT OF OZONE CONCENTRATION PROFILE OVER THE KOREAN PENINSULA USING THE KOREAN SOUNDING ROCKET KSR-420S : OZONE DETECTOR, ITS CALIBRATION AND DATA REDUCTION

  • Kim, Jhoon;Ryoo, Jang-Soo;Park, Chang-Joon;Lim, Heung-Bin;Lee, Ki-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.193-202
    • /
    • 1992
  • The fist sounding rocket in Korea, KSR-420S has been under the development at Korea Aerospace Research Institute (KARI), and is expected to be launched in 1993 to measure the vertical ozone profile over the Korean Peninsula. The KSR-420S is expected to provide the fist in situ measurement of ozone concentrations over the Korean Peninsula. An optical ozone detector has been developed at Korea Research Institute of Standards and Science (KRISS), and its calibration has been completed recently. In this paper, measurement principles of the ozone detector in KSR-420S, its calibration data, ozone measurement procedure and data reduction algorithm are presented with sample calculations.

  • PDF

VICARIOUS GROUND CALIBRATION OF AIRBORNE MULTISPECTRAL SCANNER (AMS) DATA BASED ON FIELD CAMPAIGN

  • Lee, Kwang-Jae;Kim, Yong-Seung;Han, Jong-Gyu
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.184-187
    • /
    • 2006
  • The radiometric correction is prerequisite to derive both land and ocean surface properties from optical remote sensing data. Radiometric calibration of remotely sensed data has traditionally been accomplished by means of vicarious ground calibration techniques. The purpose of this study is to calibrate the radiometric characteristic of Airborne Multispectral Scanner (AMS) by field campaign. In order to calibrate the AMS data, four different spectral tarps which are 3.5%, 23%, 35%, and 53% were validated by GER-3700 that is the surface reflectance measurement equipment and were utilized. After validation of the spectral tarps, each reflectance from the spectral tarps was compared with Digital Number (DN) value of AMS. There was very high correlation between tarp reflectance and DN value of AMS so that radiometric calibration of AMS data has been accomplished by those results. The calibrated AMS data were validated with in-situ measured reflectance data from artificial and natural target. Also QuickBird image data were used for verifying the results of AMS radiometric calibration. This presentation discusses the results of the above tests.

  • PDF