• Title/Summary/Keyword: In-site evaluation method

Search Result 868, Processing Time 0.03 seconds

Evaluation of Intrinsic Bioremediation of Methyl Tert-butyl Ether (MTBE) Contaminated Groundwater

  • Chen, Colin S.;Tien, Chien-Jun;Zhan, Kai-Van
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.5
    • /
    • pp.9-17
    • /
    • 2014
  • This paper reported the use of real-time polymerase chain reaction (PCR), denaturing gradient gel electrophoresis (DGGE), and the culture-based method in the intrinsic bioremediation study at a petroleum contaminated site. The study showed that phenol hydroxylase gene was detected in groundwater contaminated with benzene, toluene, ethylbenzene, xylene isomers (BTEX) and methyl tert-butyl ether (MTBE). This indicated that intrinsic bioremediation occurred at the site. DGGE analyses revealed that the petroleum-hydrocarbon plume caused the variation in microbial communities. MTBE degraders including Pseudomonas sp. NKNU01, Bacillus sp. NKNU01, Klebsiella sp. NKNU01, Enterobacter sp. NKNU01, and Enterobacter sp. NKNU02 were isolated from the contaminated groundwater using the cultured-based method. Among these five strains, Enterobacter sp. NKNU02 is the most effective stain at degrading MTBE without the addition of pentane. The MTBE biodegradation experiment indicated that the isolated bacteria were affected by propane. Biodegradation of MTBE was decreased but not totally inhibited in the mixtures of BTEX. Enterobacter sp. NKNU02 degraded about 60% of MTBE in the bioreactor study. Tert-butyl alcohol (TBA), acetic acid, 2-propanol, and propenoic acid were detected using gas chromatography/mass spectrometry during MTBE degraded by the rest cells of Enterobacter sp. NKNU02. The effectiveness of bioremediation of MTBE was assessed for potential field-scale application.

Sea Environmental Design Criteria for Coastal and Offshore Structures

  • Liu, Defu
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.19-22
    • /
    • 1996
  • Extreme sea statistics and combinations of environmental events or response for structures are very important problem in performance evaluation and design of coastal and Offshore structures. A probabilistic method is developed that leads to the combination of Typhoon (Hurricane) or winter storm induces winds, waves, currents and surge for a generic site. The traditional recommendation for the fixed structures is a combination of the 100 years maximum wave height with the 100 years wind and current. (omitted)

  • PDF

Evaluation of hydropower dam water supply capacity (I): individual and integrated operation of hydropower dams in Bukhan river (발전용댐 이수능력 평가 연구(I): 북한강수계 개별 댐 및 댐군 용수공급능력 분석)

  • Jeong, Gimoon;Choi, Jeongwook;Kang, Doosun;Ahn, Jeonghwan;Kim, Taesoon
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.7
    • /
    • pp.505-513
    • /
    • 2022
  • Recently, uncertainty in predicting available water resources is gradually increasing due to climate change and extreme weather conditions. Social interest in water management such as flood and drought prevention is also increasing, and after the unification of water management implemented in 2018, domestic water management is facing a major turning point. As part of such strengthening of water management capabilities, various studies are being conducted to utilize a hydropower dam for flood control and water supply purposes, which was mainly operated for hydroelectric power generation. However, since the dam evaluation methods developed based on a multi-purpose dam are being applied to hydropower dams, an additional evaluation approach that can consider the characteristics of hydropower dams is required. In this study, a new water supply capacity evaluation method is presented in consideration of the operational characteristics of hydropower dams in terms of water supply, and a connected reservoir simulation method is proposed to evaluate the comprehensive water supply capacity of a dam group operating in a river basin. The presented method was applied to the hydropower dams located in the Bukhan River basin, and the results of the water supply yield of individual dams and multi-reservoir systems were compared and analyzed. In the future, the role of hydropower dams for water supply during drought is expected to become more important, and this study can be used for sustainable domestic water management research using hydropower dams.

Low Impact Urban Development For Climate Change and Natural Disaster Prevention

  • Lee, Jung-Min;Jin, Kyu-Nam;Sim, Young-Jong;Kim, Hyo-Jin
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.54-55
    • /
    • 2015
  • Increase of impervious areas due to expansion of housing area, commercial and business building of urban is resulting in property change of stormwater runoff. Also, rapid urbanization and heavy rain due to climate change lead to urban flood and debris flow damage. In 2010 and 2011, Seoul had experienced shocking flooding damages by heavy rain. All these have led to increased interest in applying LID and decentralized rainwater management as a means of urban hydrologic cycle restoration and Natural Disaster Prevention such as flooding and so on. Urban development is a cause of expansion of impervious area. It reduces infiltration of rain water and may increase runoff volume from storms. Low Impact Development (LID) methods is to mimic the predevelopment site hydrology by using site design techniques that store, infiltrate, evaporate, detain runoff, and reduction flooding. Use of these techniques helps to reduce off-site runoff and ensure adequate groundwater recharge. The contents of this paper include a hydrologic analysis on a site and an evaluation of flooding reduction effect of LID practice facilities planned on the site. The region of this Case study is LID Rainwater Management Demonstration District in A-new town and P-new town, Korea. LID Practice facilities were designed on the area of rainwater management demonstration district in new town. We performed analysis of reduction effect about flood discharge. SWMM5 has been developed as a model to analyze the hydrologic impacts of LID facilities. For this study, we used weather data for around 38 years from January 1973 to August 2014 collected from the new town City Observatory near the district. Using the weather data, we performed continuous simulation of urban runoff in order to analyze impacts on the Stream from the development of the district and the installation of LID facilities. This is a new approach to stormwater management system which is different from existing end-of-pipe type management system. We suggest that LID should be discussed as a efficient method of urban disasters and climate change control in future land use, sewer and stormwater management planning.

  • PDF

Hazard-Consistent Ground Displacement Estimation for Seismic Input of Underground Utility Tunnels in Korea (국내 재해도에 상응하는 공동구의 지반변위 산정)

  • Kim, Dae-Hwan;Lim, Youngwoo;Chung, Yon-Ha;Lee, Hyerin
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.12
    • /
    • pp.7-23
    • /
    • 2021
  • Underground utility tunnels, which contribute to supply of electricity, communication, water and heat, are critical lifelines of an urban area. In case service is discontinued or functional disruption happens, there will be a huge socio-economic impact. For the improved seismic design and evaluation of underground structures, this study proposes a ground displacement measure when the site is subjected to a scenario earthquake based on hazard-consistent source spectra and site amplification/attenuation. This measure provides a rational estimation of ground displacement and can be an alternative to existing response displacement methods.

A Study on the Evaluation of Dynamic Behavior and Liquefaction Cau8ed by Earthquake of Sea Dike Structures on the Ground (방조제 축조 예정지반의 지진에 의한 액상화 거동 평가)

  • 도덕현;장병욱;고재만
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.2
    • /
    • pp.43-56
    • /
    • 1993
  • The laboratory tests are performed on how the liquefaction potential of the sea dike structures on the saturated sand or silty sand seabed could be affected due to earthquake before and after construction results are given as follows ; 1. Earthquake damages to sea dike structures consist of lateral deformation, settlement, minor abnormality of the structures and differential settlement of embankments, etc. It is known that severe disasters due to this type of damages are not much documented. Because of its high relative cost of the preventive measures against this type of damages, the designing engineer has much freedom for the play of judgement and ingenuity in the selection of the construction methods, that is, by comparing the cost of the preventive design cost at a design stage to reconstruction cost after minor failure. 2. The factors controlling the liquefaction potential of the hydraulic fill structure are magnitude of earthquake(max. surface velocity), N-value(relative density), gradation, consistency(plastic limit), classification of soil(G & vs), ground water level, compaction method, volumetric shear stress and strain, effective confining stress, and primary consolidation. 3. The probability of liquefaction can be evaluated by the simple method based on SPT and CPT test results or the precise method based on laboratory test results. For sandy or silty sand seabed of the concerned area of this study, it is said that evaluation of liquefaction potential can be done by the one-dimensional analysis using some geotechnical parameters of soil such as Ip, Υt' gradation, N-value, OCR and classification of soils. 4. Based on above mentioned analysis, safety factor of liquefaction potential on the sea bed at the given site is Fs =0.84 when M = 5.23 or amax= 0.12g. With sea dike structures H = 42.5m and 35.5m on the same site Fs= 3.M~2.08 and Fs = 1.74~1.31 are obtained, respectively. local liquefaction can be expected at the toe of the sea dike constructed with hydraulic fill because of lack of constrained effective stress of the area.

  • PDF

Health Evaluation and Fish Population Analysis by Using LEHA (Lentic Ecosystem Health Assessment) Model (LEHA 모델을 이용한 어류군집 특성 분석 및 건강성 평가)

  • Han, Seock-Jung;Kim, Bong-Rae;Cha, Jun-Seong;Kang, Kyoung-Ho;Jung, Min-Min
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1185-1192
    • /
    • 2014
  • Health assessment of aquatic ecosystem was investigated by using LEHA (Lentic Ecosystem Health Assessment) model method with habitat fish population structure analysis in this study. The investigation was two comparison spots (St 1; floating island, St 2; 500 m away site from st 1) in the Habcheon lake of Korea. As results, health evaluation of Habcheon lake ecosystem was fair grade of LEHA scores base on metric values in both place (30 score in st. 1 and 32 score in st. 2).

Development of Work Clothing for the Construction Site (건설현장 근로자인 작업복 개발에 관한 연구)

  • Chang Sun-Ok;Choi Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.7 s.155
    • /
    • pp.1090-1102
    • /
    • 2006
  • The purpose of this study is to develop an improved work clothing which is much safe, comfortable, mobility and convenient than what workers currently wear at construction site. The investigation has been conducted to evaluate current work clothing to grasp any problems, discomforts and damages related to the work clothing. For the best and accurate data, hands-on investigation and a short-interview have been performed at the construction site as well as formulating a questionnaire. The questionnaires was answered by 425 workers and safety manager of 13 different construction site. The result of the questionnaire enables us to design a sample work clothing, many pa π s such as material, pattern and design have been improved. To improve the amenity of heat, the surface of a material was used by $Aerocool^{\circledR}$ fiber which contains inside dryness function. In order to absorb perspiration on the back the armpits, mesh martial that is mixture of $Coolever^{TM}$ fiber and $Mirawave^{TM}$ fiber was used to absorb perspiration in an effective manner. And a sleeve's bottom part and trousers' bottom part's cover method have been changed. Sample work clothing was shorten at the side of upper garment up to 2cm and lengthen the length of the back by 3cm. To reduce the tightness around armpit more room was given in that area. Darts were added to the elbow, the hip, and the knees that also followed an ergonomic pattern. A sample work clothing evaluated an objective assessment and subjective assessment to compare to a current work clothing. Assessment group consists of seven subject groups and nine expert groups to evaluate external appearance and adaptability to the movements. In all aspects of the test, the result of evaluation process of the sample work clothing received more positive assessment than the current work clothing.