• Title/Summary/Keyword: In-process diagnosis

Search Result 1,575, Processing Time 0.027 seconds

Multiple fixed implant-supported prosthesis using temporary denture and scannable healing abutment: a case report (임시의치와 스캔가능한 치유지대주를 이용한 고정성 임플란트 보철 수복 증례)

  • Hyung-Jun Kim;Hyeon Kim;Woo-hyung Jang;Kwi-dug Yun;Sang-Won Park;Hyun-Pil Lim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.250-259
    • /
    • 2023
  • The use of digital technology in fixed prosthetic treatment using implants enables predictive treatment through diagnosis and virtual surgery by integrating clinical and radiological information of patients. Existing digital scanning methods require several components to be removed, such as removing the healing abutment and connecting the scan body. In the scannable healing abutment developed in consideration of this point, scanning is performed directly on the healing abutment, maintaining soft tissue sealing and simplifying scanning. Digital technology can also be used when obtaining the intermaxillary relationship. Recently, various digital technologies have been reported to acquire the intermaxillary relationship of edentulous patients using surgical guides, patient-specific scanning devices, or scans of the inside of temporary dentures. In this case, the implant-supported fixed prosthesis treatment was performed through scanning the scannable healing abutment and the inner side of the temporary denture to obtain the intermaxillary relationship, thereby simplifying the treatment process and obtaining aesthetically and functionally excellent clinical results.

An Error Examination of 3D Face Automatic Recognition (3차원 안면자동인식기의 형상복원 오차검사)

  • Suk, Jae-Hwa;Cho, Kyung-Rae;Cho, Yong-Beum;Yoo, Jung-Hee;Kwak, Chang-Kyu;Lee, Soo-Kyung;Kho, Byung-Hee;Kim, Jong-Won;Kim, Kyu-Kon;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.2
    • /
    • pp.41-49
    • /
    • 2006
  • 1. Objectives The Face is an important standard for the classification of Sasang Contitutions. We are developing 3D Face Automatic Recognition Apparatus to analyse the facial characteristics. So We should examine a shape demobilization error of 3D Face Automatic Recognition Apparatus. 2. Methods We compared facial shape data be demobilized by 3D Face Automatic Recognition Apparatus with facial shape data that be demobilized by 3D laser scanner. The subject was two korean men. And We analysed the average error and the maximum error of two data. In this process, We used one datum point(the peak of nose) and two datum line(vertical section and horizontal section). 3. Results and Conclusions In each this comparison, the average error of vertical section was 1.962574mm and 2.703814mm. and the maximum error of vertical section was 16.968249mm and 18.61464mm. the average error of horizontal section was 4.173203mm and 21.487479mm. and the maximum error of horizontal section was 3.571210mm and 17.13255mm. Also We complemented this apparatus a little and We reexamined a shape demobilization error of 3D Face Automatic Recognition Apparatus again. Accuracy of a shape demobilization was improved a little. From now on We complement accuracy of a shape demobilization in 3D Face Recognition Apparatus.

  • PDF

Design of a CMOS x-ray line scan sensors (CMOS x-ray 라인 스캔 센서 설계)

  • Heo, Chang-Won;Jang, Ji-Hye;Jin, Liyan;Heo, Sung-Kyn;Kim, Tae-Woo;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2369-2379
    • /
    • 2013
  • A CMOS x-ray line scan sensor which is used in both medical imaging and non-destructive diagnosis is designed. It has a pixel array of 512 columns ${\times}$ 4 rows and a built-in DC-DC converter. The pixel circuit is newly proposed to have three binning modes such as no binning, $2{\times}2$ binning, and $4{\times}4$ binning in order to select one of pixel sizes of $100{\mu}m$, $200{\mu}m$, and $400{\mu}m$. It is designed to output a fully differential image signal which is insensitive to power supply and input common mode noises. The layout size of the designed line scan sensor with a $0.18{\mu}m$ x-ray CMOS image sensor process is $51,304{\mu}m{\times}5,945{\mu}m$.

A Fat Density Mass in the Mediastinum (지방음영을 보인 종격동내 종괴)

  • Heo, Su Beom;Roh, Eun Suk;Kim, Dae Sung;Kim, Eui Hiung;Kang, Ji Ho;Lee, Sang Haak;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak;Park, Chan Beom;Lee, Bae Young;Kim, Hyeon Sook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.2
    • /
    • pp.188-192
    • /
    • 2005
  • A 47-year-old female was admitted for an evaluation of a left mediastinal mass. The chest X-ray performed 16 months ago was normal, but the chest X-ray upon admission showed a large mass adjacent to the anterior aspect of the left hemidiaphragm. The CT scan demonstrated a large mass with a fat density in the left lower hemithorax. A focal diaphragmatic defect behind the xiphoid process was suspected. A thoracoscopic examination revealed omental herniation through the diaphragmatic defect. Therefore, a left thoracotomy was performed and the defect was repaired. We believe that a differential diagnosis should be needed to include a diaphragmatic omental hernia when a fat density mass is observed in the mediastinum.

Multiple Xanthomatosis in Familiar Hypercholesterolemia Patient - A case report - (가족성 고콜레스테롤혈증 환자에서의 다발성 황색종 - 1례 보고 -)

  • Rhee, Seung-Koo;Lee, Hwa-Sung;Moon, Chan-Woong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2000
  • We experienced the case of familiar hypercholesterolemia with multiple xanthomas which was treated by combined surgical and medical therapy. He was 26-year-old male patient of familiar hypercholesterolemia with multiple xanthomas in 22 sites on whole body, and was treated by 17 surgical excisions of the xanthomas and by medical therapy of the hypercholesterolemia. There was a normal healing process of the surgical wounds. Continual postoperative medical therapy of the hypercholesterolemia was done. There was no recurrence of the symptoms during more than 13 months of follow-up. But the serum level of the cholesterol was not lowered significantly, so we are treating him with drug therapy. Familial hypercholesterolemia is caused by a specific disorder of lipid metabolism, and is characterized by increased LDL cholesterol, tendon xanthomas, coronary disease associated with autosomal dominant transmission. Xanthomas usually appear in the second decade of life with familiar hypercholesterolemia which may have high risk for premature coronary atherosclerosis, which might be prevented with early diagnosis and medical treatment. So, orthopedic surgeons do not only excise the xanthomatosis surgically but also can diagnose the underlying hypercholesterolemia.

  • PDF

Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report (구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례)

  • Chang, Yun-Jeong;Kim, Hong-Jun;Song, Mi-Kyoung;Moon, Ji-Eun;Lee, Hal-La;Park, Chan-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.234-243
    • /
    • 2015
  • Developing of digital technique, it is possible to fabricate implant prostheses for edentulous area using intraoral 3-dimentional information throughout implant diagnosis and treatment process. It is being changed that from the method using CAD/CAM, producing prostheses by model scanning after conventional impression and model processing, to the method of fabricating implant provisional restorations and customized abutments by digital impression after connecting digital impression copings (scanbody) and implant fixtures without models. But, this digital method has not been actively used for implant prostheses not yet. Specially, it is short of intraoral digital impression cases for immediate provisional restorations of the maxillary anterior implants. The gingival contour impression of maxillary anterior area is very important for esthetic restorations. Accordingly, in this case report, the using a digital impression coping (scanbody) and digital impression by CEREC Omnicam (Sirona, Bensheim, Germany) or Trios (3shape, Copenhagen, Denmark) were introduced for immediate provisional restorations in 3 cases needed a single implant restoration in maxillary anterior area. The clinical results were satisfactory on the convenience and accuracy of digital impression technique and the good esthetics of final restorations.

Wheel tread defect detection for high-speed trains using FBG-based online monitoring techniques

  • Liu, Xiao-Zhou;Ni, Yi-Qing
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.687-694
    • /
    • 2018
  • The problem of wheel tread defects has become a major challenge for the health management of high-speed rail as a wheel defect with small radius deviation may suffice to give rise to severe damage on both the train bogie components and the track structure when a train runs at high speeds. It is thus highly desirable to detect the defects soon after their occurrences and then conduct wheel turning for the defective wheelsets. Online wheel condition monitoring using wheel impact load detector (WILD) can be an effective solution, since it can assess the wheel condition and detect potential defects during train passage. This study aims to develop an FBG-based track-side wheel condition monitoring method for the detection of wheel tread defects. The track-side sensing system uses two FBG strain gauge arrays mounted on the rail foot, measuring the dynamic strains of the paired rails excited by passing wheelsets. Each FBG array has a length of about 3 m, slightly longer than the wheel circumference to ensure a full coverage for the detection of any potential defect on the tread. A defect detection algorithm is developed for using the online-monitored rail responses to identify the potential wheel tread defects. This algorithm consists of three steps: 1) strain data pre-processing by using a data smoothing technique to remove the trends; 2) diagnosis of novel responses by outlier analysis for the normalized data; and 3) local defect identification by a refined analysis on the novel responses extracted in Step 2. To verify the proposed method, a field test was conducted using a test train incorporating defective wheels. The train ran at different speeds on an instrumented track with the purpose of wheel condition monitoring. By using the proposed method to process the monitoring data, all the defects were identified and the results agreed well with those from the static inspection of the wheelsets in the depot. A comparison is also drawn for the detection accuracy under different running speeds of the test train, and the results show that the proposed method can achieve a satisfactory accuracy in wheel defect detection when the train runs at a speed higher than 30 kph. Some minor defects with a depth of 0.05 mm~0.06 mm are also successfully detected.

Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor ($BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교)

  • Choi, Jang-Yong;Park, Ji-Koon;Gong, Hyun-Gi;Ahn, Sang-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

Optimal design of a nonparametric Shewhart-Lepage control chart (비모수적 Shewhart-Lepage 관리도의 최적 설계)

  • Lee, Sungmin;Lee, Jaeheon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.2
    • /
    • pp.339-348
    • /
    • 2017
  • One of the major issues of statistical process control for variables data is monitoring both the mean and the standard deviation. The traditional approach to monitor these parameters is to simultaneously use two seperate control charts. However there have been some works on developing a single chart using a single plotting statistic for joint monitoring, and it is claimed that they are simpler and may be more appealing than the traditonal one from a practical point of view. When using these control charts for variables data, estimating in-control parameters and checking the normality assumption are the very important step. Nonparametric Shewhart-Lepage chart, proposed by Mukherjee and Chakraborti (2012), is an attractive option, because this chart uses only a single control statistic, and does not require the in-control parameters and the underlying continuous distribution. In this paper, we introduce the Shewhart-Lepage chart, and propose the design procedure to find the optimal diagnosis limits when the location and the scale parameters change simultaneously. We also compare the efficiency of the proposed method with that of Mukherjee and Chakraborti (2012).

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.