• Title/Summary/Keyword: In-plane alignment

Search Result 173, Processing Time 0.043 seconds

Surface Topographic Measurement Method for Assessing Lower Extremity Alignment: Examination on a novel clinical and research Tool (하지 정렬 평가를 위한 체표면 토포그래피를 이용한 측정법: 새로운 임상 및 연구 도구에 대한 검토)

  • Yim, Ji-Young;Yim, Hyun-Seung;Park, Dae-Sung;Lee, Na-Kyung;Lee, Na-Kyung
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • The purpose of this study was to assess the intra-rater, inter-rater and test-retest reliability and validity of frontal plane lower extremity alignment estimated from a rasterstereographic method using ABW-Mapper. Eighteen subjects participated in this study. The S angle (stereographic angle-frontal plane lower extremity alignment estimated from a rasterstereographic method) in standing was measured throughout the two sessions with one week interval by two different readers. In the first session, a reader measured S angle twice per subject with a short break in-between. The Q-angle (quadriceps angle) was measured using a standard goniometer from a photography taken through digital camera with the participant standing in the same position as in the S angle measurement. The HKA(hip-knee-ankle) angle was measured from a computer based digital radiograph with the computerized measurement software. Reliability was tested using intraclass correlation coefficients(ICC). Validity was tested using a Pearson's correlation coefficient. Excellent intra-rater(ICC=0.956~0.974), inter-rater(ICC=0.962), test-retest reliability (ICC=0.945) were demonstrated. There were strong negative correlations between S angle and Q-angle (r=-0.739), and between S angle and HKA angle (r=-0.702). Therefore, the S angle measured using a rasterstereographic mapper may be used to as a preliminary or supplementary tool to evaluate and study LE alignment in the frontal plane in relation to HKA angle or Q-angle.

3-D FEM Study on the Optical Characteristics of S-IPS Mode

  • Yang, Seung-Su;Park, Soon-Yeol;Won, Tea-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.231-234
    • /
    • 2008
  • In this paper, we propose a novel electrode structure for superb transmittance in super in-plane switching (S-IPS) mode while keeping the features of the conventional SIPS mode such as the capability of initial LC alignment. The optimization of the electrode made it possible to enhance the light transmittance approximately by 14 % in comparison to the conventional S-IPS cell.

  • PDF

Effect of the Alignment of Milled Carbon Fiber Dispersed in Various Solvents (Solvent 별 분산에 따른 Milled Carbon Fiber의 배열성 연구)

  • Lee, Sung-Kwon;Choi, Sung-Woong
    • Composites Research
    • /
    • v.35 no.1
    • /
    • pp.47-51
    • /
    • 2022
  • In order to efficiently control the heat generation of electronic devices, many research has been conducted on thermally conductive composite materials. In this study, milled carbon fiber was dispersed in four solvent to investigate the relationship of carbon fiber alignment according to dispersion by solvents, and carbon fiberreinforced composite material(CFRP) was manufactured using vacuum filtration. To evaluate the arrangement of CFRP the arrangement of the prepared specimen was observed under an optical microscope, and thermal conductivity was measured by Laser Flash Analysis. The Through-plane thermal conductivity of CFRP using NMP and Ethanol was 10.79 W/mK and 10.57 W/mK respectively, which were improved by 218% and 209% compared to the In-plane thermal conductivity. The high viscosity of the solvent greatly affects the shear of the fluid, and it seemed to determine the alignment of the filler.

MTF Measurement for Flight Model of MAC, a 2.5m GSD Earth Observation Camera (2.5m 해상도 지구관측 카메라 MAC 비행모델의 지상 MTF 성능 측정)

  • Kim, Eugene-D.;Choi, Young-Wan;Yang, Ho-Soon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.10
    • /
    • pp.98-103
    • /
    • 2005
  • The Flight Model of MAC (Medium-sized Aperture Camera), a 2.5m GSD class earth observation camera has been aligned and assembled. Topics discussed in this paper include the ground MTF performance of the MAC system, and the alignment of the focal plane assembly. MTF was measured by a knife-edge scanning technique, and a 450 mm diameter Cassegrain collimator with diffraction-limited performance was made and used for the MTF measurements. System MTF was used as the figure-of-merit to find the best focus of the focal plane assembly.

23' LCD TV by using ALT plasma beam alignment technology

  • Lee, C.Y.;Tang, H.C.;Chen, C.W.;Shih, Y.J.;Liu, C.H.;Lin, C.H.;Yang, K.H.;Lin, S.H.;Chang, H.C.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.776-779
    • /
    • 2006
  • The alignment of liquid crystal (LC) is one of the key issues of liquid crystal display (LCD) technologies. In this study, we aligned polyimide (as the LC alignment layer) by ALT plasma beam and to realize the stability and characteristics of this technology. The characteristics such as anchoring energy, pre-tilt angle, voltage holding ratio(VHR) and residual direct current(Rdc) were discussed. Besides, we applied it to the in plane switch (IPS) mode 23" WXGA real panel, the performance parameters and electrical properties were measured and compared with those of rubbing alignment. From the result, we demonstrated a successful LC alignment treatment process in real panel by ALT plasma beam.

  • PDF

Molecular Orientation of Evaporated Pentacene Film on Polyimide Alignment Layer (폴리이미드 배향막에 증착된 Pentacene 분자의 배향 연구)

  • Kim Beom-Kyung;Kim Do-Hoi;Chung Jae-Sun;Kim Young-Ju;Seo In-Seon;Kwon Soon-Ki;Song Ki-Gook
    • Polymer(Korea)
    • /
    • v.30 no.4
    • /
    • pp.362-366
    • /
    • 2006
  • It was found by polarized FTIR spectroscopic studies that pentacene molecules are arranged with their molecular axes perpendicular to the substrate surface when pentacene films are deposited on a polyimide alignment layer. The ring plane in a pentacene molecule is arranged parallel to the rubbing direction of the polyimide alignment film while no specific arrangement of vertically deposited pentacene molecules was found for the film without rubbing. The pentacene band at $1296cm^{-1}$ which has a transition dipole moment parallel to the ring plane is much stronger in a polarized IR spectrum of parallel to the rubbing direction, whereas the band at $908cm^{-1}$ whose transition dipole align normal to the ring plane shows much stronger intensity in a spectrum of perpendicular to the rubbing direction. These findings indicate that orientation of polyimide chains affects the arrangement of pentacene molecules when they are deposited on a polyimide alignment film.

Bistable Liquid Crystal Device Realized on Microscopic Orientational Pattern

  • Kim, Jong-Hyun;Yoneya, Makoto;Yokoyama, Hiroshi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.187-190
    • /
    • 2005
  • Alignment pattern of checkerboard was constructed by the stylus of atomic force microscope. Orientational bistability of the nematic liquid crystal was realized on that frustrated surface alignment. Macroscopic orientational switching between two perpendicular directions took place by an appropriate in-plane electric field. The threshold electric fields decreased in both switching directions as temperature increased. The focused laser heated up only the limited domains in the cell including a light-absorbing medium. Irradiating the laser concurrently with an appropriate electric field, we switched the selected unit domains in the alignment pattern. The switched domains maintained stably the switched direction without the disturbance from the exterior. Extending and repeating this process, we realized extremely fine devices of bistable switching.

  • PDF

Depth error correction for maladjusted stereo cameras with the calibrated pixel distance parameter (화소간격 파라미터 교정에 의한 비정렬 스테레오 카메라의 거리오차 보정)

  • 김종만;손홍락;김성중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.268-272
    • /
    • 1996
  • Error correction effect for maladjusted stereo cameras with calibrated pixel distance parameter is presented. The camera calibration is a necessary procedure for stereo vision-based depth computation. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. No effective methods for such alignment have been presented before. Some amount of depth error caused from such non-parallel installation of cameras is inevitable. If the pixel distance parameter which is one of intra parameter is calibrated with known points, such error can be compensated in some amount. Such error compensation effect with the calibrated pixel distance parameter is demonstrated with some experimental results.

  • PDF

A Study on the Mechanism of Rotational Stage for Optical Fiber Alignment (다채널 광소자 정렬 장치의 회전스테이지 구동 메커니즘 연구)

  • Jeong S.H.;Cha K.R.;Kim H.U.;Choi S.B.;Kim G.H.;Park J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1514-1517
    • /
    • 2005
  • In recent years, as the demands of VBNS(Very high speed Backbone Network Service) and VDSL(Very high-data rate Digital Subscriber Line) increase, the development of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, WDM elements increase. The alignment and the attachment technology are very important to fabricate the optical elements for communication. In this paper, the mechanism of rotational stage are studied. with the three different method and the results of them are applied to the design of the system. The performance test of resolution and travel is performed.

  • PDF

A Study on the Mechanism of Rotational Stage with Multi Degree of Freedom for Multi-Channel Optical Alignment System (다채널 광정렬 장치에서의 다자유도 회전 스테이지 동작 특성에 관한 연구)

  • Jeong Sanghwa;Cha Kyoungrae;Kim Hyunuk;Choi Sukbong;Kim Kwangho;Park Junho
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.150-155
    • /
    • 2005
  • In recent years, as the demands of VBNS(Very high speed Backbone Network Service) and VDSL(Very high-data rate Digital Subscriber Line) increase, the development of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, WDM elements increase. The alignment and the attachment technology are very important to fabricate the optical elements for communication. In this paper, the mechanism of rotational stage are studied. with the three different method and the results of them are applied to the design of the system. The performance test of resolution and travel is performed.

  • PDF