• Title/Summary/Keyword: In-plane Motion

Search Result 753, Processing Time 0.019 seconds

Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns (전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교)

  • Ko, In-Seok;Kim, Jeong-Mi;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.226-233
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the adaptation of lithium disilicate crowns fabricated by CAD-CAM (computer aided design-computer aided manufacturing) and heat-press technique to compare two different measurement methods in assessing fit of the ceramic crowns: micro CT and cross-section technique. Materials and methods: A prepared typodont mandibular molar for ceramic crown was duplicated and ten dies were produced by milling the PMMA (polymethylmethacrylate) resin. Ten vinyl polysiloxane impressions were made and stone casts were produced. Five dies were used for IPS e.max Press crowns with heat-press technique. The other five dies were used for IPS e.max CAD crowns with CAD-CAM technique. Ten lithium disilicate crowns were cemented on the resin dies using zinc phosphate cement with finger pressure. The marginal and internal fits in central buccolingual plane were evaluated using a micro CT. Then the specimens were embedded and cross-sectioned and the marginal and internal fits were measured using scanning electronic microscope. The two measurement methods and two manufacturing methods were compared using Mann-Whitney U test (SPSS 22.0). Results: The marginal and internal fit values using micro CT and cross-section technique were similar, showing no significant differences. There were no significant differences in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique. Conclusion: Both micro CT and cross-section technique were acceptable methods in the evaluation of marginal and internal fit of lithium disilicate crown. There was no difference in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique except occlusal fit.

Study on the Differences in the Results of Body Shape Test According to the Position of the Two Feet and the Usefulness of the Neck and Body Motion Image Test (두 발의 위치에 따른 체형검사 결과 차이와 체간신전 동작 이미지 검사의 유용성 연구)

  • Chang, Wan Song;Kim, Song Ja;Ryu, Seo Won;Lim, Duk Joon;Jung, Moon Young
    • Journal of Naturopathy
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 2020
  • Purposes: The purposes of this study were to investigate the relationship between the standing position of the subject and the normal standing position(NSP) and the straight standing position(SSP) and to investigate the possibility of different body shape test results depending on the status of the image inspection apparatus. Methods: The images of the NSP and SSP were compared with each other by body line BLS system. Results: At the time of examination, the position of the camera was captured at a position 2.3 m vertically from the posterior position 45 cm behind the subject. This is a privacy protection method for covering the breast of the subject. Results: The physiological characteristics of the anatomical position of the body align image test are the living body. NSP and SSP tests showed different shapes of the pelvis AS(antero-supero) and pelvis rotation in the transverse plane. Shoulder and arm displacement was observed in the trunk extension image capture. Conclusions: In the body alignment test, the pelvis position test images of NSP and SSP are evaluated differently for pelvis rotation, AS, and PS. At the extension position of the trunk, a test of the maximal extension range showed that the left and right shortening of the shoulder anterior muscles could be observed. Inducing and testing the trunk extension is also useful.

Evaluation of Geometric Correspondence of kV X-ray Images, Electric Portal Images and Digitally Reconstructed Radiographic Images (kV X선 영상, 전자조사문 영상, 디지털화재구성 영상 간 기하학적 일치성 평가)

  • Cheong, Kwang-Ho;Kim, Kyoung-Joo;Cho, Byung-Chul;Kang, Sei-Kwon;Juh, Ra-Hyeong;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.118-125
    • /
    • 2007
  • In this study we estimated a geometric correlation among digitally reconstructed radiographic image (DRRI), kV x-ray image (kVXI) from the On-Board Imager (OBI) and electric portal image (EPI). To verify geometric correspondence of DRRI, kVXI and EPI, specially designed phantom with indexed 6 ball bearings (BBs) were employed. After accurate setup of the phantom on a treatment couch using orthogonal EPIs, we acquired set of orthogonal kVXIs and EPIs then compared the absolute positions of the center of the BBs calculated at each phantom plane for kVXI and EPI respectively. We also checked matching result for obliquely incident beam (gantry angle of $315^{\circ}$) after 2D-2D matching provided by OBI application. A reference EPI obtained after initial setup of the phantom was compared with 10 series of EPIs acquired after each 2D-2D matching. Imaginary setup errors were generated from -5 mm to 5 mm at each couch motion direction. Calculated positions of all center positions of the BBs at three different images were agreed with the actual points within a millimeter and each other. Calculated center positions of the BBs from the reference and obtained EPIs after 2D-2D matching agreed within a millimeter. We could tentatively conclude that the OBI system was mechanically quite reliable for image guided radiation therapy (IGRT) purpose.

  • PDF