• 제목/요약/키워드: In-pile Test

검색결과 1,075건 처리시간 0.027초

원자로 내 핵연료조사시험용 압력용기조립체 설계 (Design of Vessel Assembly for Fuel Irradiation Test in Reactor)

  • 박국남;이종민;지대영;박수기;이정영;김영진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.383-387
    • /
    • 2004
  • The Fuel Test Loop (FTL) consists of In-Pile Test Section (IPS) and Out-of-Pile System (OPS). The test condition in IPS such as pressure, temperature and quality of the main cooling water, can be controlled by the OPS. The FTL has been developed to be able to irradiate three pins to the core irradiation hole (IR1 hole) by considering for its utility and user's irradiation requirement. The IPS vessel assembly (IVA) consists of IPS head, outer pressure vessel, inner pressure vessel, inner assembly and test fuel carrier. The IVA is approximately 5.6 m long and fits within a 74 mm in diameter envelope over the full height of the chimney. Above the top of the chimney, the head of the IPS is enlarged to allow the closure flanges and pipe work connections. IVA was designed to test the CANDU and PWR nuclear fuel pin together. Specially, wished to minimize interference by nuclear fuel change in design and synthesize these items and shape design for IVA.

  • PDF

광양지역 고강도 강관 항타말뚝의 설계효율 향상 방안 연구 (Design Efficiency Improvement Method Research for High Strength Steel Pipe Pile at Gwangyang Area)

  • 나승민;유한규
    • 대한토목학회논문집
    • /
    • 제31권6C호
    • /
    • pp.231-240
    • /
    • 2011
  • 소재의 고강도화와 항타에너지 상향 반영에 따른 강관말뚝의 거동특성을 분석하기 위하여 광양지역에 다양한 지름과 소재별로 총 10본의 말뚝을 시공하여 동재하시험, 정재하시험, 하중전이시험 등의 다양한 현장재하시험을 수행하였다. 항타관입성을 분석한 결과, PHC말뚝이 가장 많은 항타횟수와 가장 적은 관입깊이를 나타냈으며 고강도 강관말뚝에서 가장 적은 항타횟수와 깊은 관입깊이를 확인할 수 있어 고항타에너지에 의한 효과를 파악할 수 있었다. 동재하시험결과를 말뚝별로 비교한 결과, PHC말뚝과 일반 강관말뚝의 경우에는 재료의 허용축하중이 말뚝의 설계허용지지력을 결정하는 주요 변수인 것을 확인한 반면에 고강도 강관말뚝에서는 지반의 지지력에 의해 말뚝의 설계허용지지력이 결정되는 것을 확인할 수 있었다. 정재하시험과 하중전이시험을 고강도 강관말뚝 2본에 대해서 수행한 결과, 말뚝의 설계효율을 80% 이상의 수준으로 향상할 수 있는 방안을 도출할 수 있었으며 이를 통해 소요 말뚝 본수 절감을 통한 공사비 절감이 가능함을 확인하였다. 대상 지역에서의 주면마찰력 set-up효과를 분석하여 적정 회귀식을 제시하였고 선단지지력에 대해서는 기존 설계식의 한계를 분석하여 향후 기술개발 방향을 제시할 수 있었다.

1g 진동대 실험을 이용한 사질토 지반에서의 동적 군말뚝 효과 분석 (Evaluation of Dynamic Group Pile Effect in Sand by 1 g Shaking Table Tests)

  • 양의규;최정인;한진태;김명모
    • 한국지반공학회논문집
    • /
    • 제26권8호
    • /
    • pp.77-88
    • /
    • 2010
  • 본 연구에서는 다양한 상대밀도의 건조, 포화 사질토 지반을 조성하고, 군말뚝의 중심 간격을 말뚝 지름의 3배, 5배, 7배로 조정하며 1g 진동대 실험을 수행하였다. 실험으로 얻은 동적 p-y 곡선을 분석하여, 말뚝중심간 간격, 군말뚝 내말뚝의 위치, 지반의 상대밀도, 그리고 진동 중 발생하는 과잉간극수압에 따라 군말뚝의 동적 p-y 곡선이 달라지는 것을 확인하였다. Yang 등(2009)이 제시한 단말뚝의 동적 p-y 중추곡선과 군말뚝의 동적 p-y 곡선을 비교하여 동적 p-승수를 산정해본 결과, 입력가속도 진폭과 지반의 상대밀도가 증가할수록 p-승수의 값이 증가하였으며, 말뚝 중심 간격이 말뚝지름의 7배가 되었을 경우 군말뚝 효과가 사라지는 것으로 나타났다. 기존의 연구자들이 제안한 정적, 동적 p-승수 값들과 우리나라 기준서에서 제안하고 있는 p-승수 값들은 살험값과 비교하여 최대 0.7(약 70%) 정도까지 차이를 보였으며 이에 본 연구에서는 말뚝 중심 간격과 지반의 상대밀도를 기준으로 동적 p-승수 값을 새롭게 제안하였다.

변위억제형 Sheet pile 설치에 따른 SCP복합지반의 지지력 특성 (Characteristics of Bearing Capacity for SCP Composite Ground reinforced by the Sheet piles Restraining Deformation)

  • 박병수
    • 한국항해항만학회지
    • /
    • 제30권8호
    • /
    • pp.711-719
    • /
    • 2006
  • 본 연구는 변위억제형 Sheet pile 이 설치된 SCP복합지반의 지지력 특성에 대한 연구로서 원심모형실험과 수치해석을 통하여 SCP 복합지반의 하중-침하 관계, 응력분담특성, 최종함수비 등의 변화에 대해 알아보았다. SCP를 기초폭의 2배로 개량한 조건과 Sheet pile를 기초 한쪽 모서리에 설치한 경우, Sheet pile를 기초 양쪽 모서리에 설치한 경우 3가지에 대하여 연직하중재하 실험을 실시하였다. 한편, 원심모형실험 결과를 모사하기 위하여 상용 유한요소 프로그램인 CRISP을 이용하였으며 수치해석시 모래다짐말뚝은 탄소성모델로 점토지반은 한계평형 상태에 기초한 수정 Cam-clay 모델을 사용하였다. 원심모형실험결과 Sheet pile이 기초파괴활동을 억지하여 항복하중강도가 증가하였으며 Sheet pile 설치에 따른 응력분담비는 $2{\sim}4$의 값을 나타내었다. 또한 수치해석 결과 Sheet pile설치에 따라 지반융기량이 $20{\sim}30%$감소하였고 수평변위는 $28{\sim}43%$ 감소효과를 나타내었다.

Centrifuge modelling of pile-soil interaction in liquefiable slopes

  • Haigh, Stuart K.;Gopal Madabhushi, S.P.
    • Geomechanics and Engineering
    • /
    • 제3권1호
    • /
    • pp.1-16
    • /
    • 2011
  • Piles passing through sloping liquefiable deposits are prone to lateral loading if these deposits liquefy and flow during earthquakes. These lateral loads caused by the relative soil-pile movement will induce bending in the piles and may result in failure of the piles or excessive pile-head displacement. Whilst the weak nature of the flowing liquefied soil would suggest that only small loads would be exerted on the piles, it is known from case histories that piles do fail owing to the influence of laterally spreading soils. It will be shown, based on dynamic centrifuge test data, that dilatant behaviour of soil close to the pile is the major cause of these considerable transient lateral loads which are transferred to the pile. This paper reports the results of geotechnical centrifuge tests in which models of gently sloping liquefiable sand with pile foundations passing through them were subjected to earthquake excitation. The soil close to the pile was instrumented with pore-pressure transducers and contact stress cells in order to monitor the interaction between soil and pile and to track the soil stress state both upslope and downslope of the pile. The presence of instrumentation measuring pore-pressure and lateral stress close to the pile in the research described in this paper gives the opportunity to better study the soil stress state close to the pile and to compare the loads measured as being applied to the piles by the laterally spreading soils with those suggested by the JRA design code. This test data shows that lateral stresses much greater than one might expect from calculations based on the residual strength of liquefied soil may be applied to piles in flowing liquefied slopes owing to the dilative behaviour of the liquefied soil. It is shown at least for the particular geometry studied that the current JRA design code can be un-conservative by a factor of three for these dilation-affected transient lateral loads.

지진 시 사질토 지반에 근입된 무리말뚝의 말뚝 캡 크기가 무리말뚝 효과에 미치는 영향 (A Group Pile Effect on Changing Size of Pile Cap in Group Pile under Sand Soil in Earthquake)

  • 이현근;안광국;강홍식
    • 한국지반환경공학회 논문집
    • /
    • 제20권10호
    • /
    • pp.39-46
    • /
    • 2019
  • 상부구조물을 지지하는 무리말뚝의 내진설계 시 지반-구조물의 상호작용이 고려되어야 한다. 무리말뚝 설계 시 지반과 구조물의 비선형 관계는 p-y 곡선이 많이 사용되고 있으며 지진과 같은 동적하중조건에서 지반-구조물의 상호작용이 고려된 동적 p-y 곡선을 무리말뚝의 내진설계에 사용하기 위한 연구가 진행되고 있다. 그러나 이와 같은 연구는 말뚝 캡에 의한 지지효과 및 상부구조물의 관성거동에 의한 상호작용은 고려되지 않았다. 이에 본 연구에서는 사질토 지반에 근입된 상부구조물을 지지하는 무리말뚝에서 말뚝 캡의 변화가 무리말뚝에 미치는 영향을 확인하기 위해 말뚝의 배열 및 중심 간격은 고정하고 말뚝 캡 측면과 말뚝 중심 간격을 변화시켜 진동대 모형실험을 수행하였다. 그 결과 무리말뚝에서 말뚝 캡 측면과 말뚝 중심 간격의 변화가 말뚝의 동적 p-y 곡선 및 무리말뚝 효과에 영향을 미치는 것으로 나타났다.

생석회파일에 의한 연약지반개량효과 (The Improvement Effects of Soft Ground by Quick Lime Pile)

  • 천병식;고갑수;장은석;임지섭;이용한
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 춘계학술대회 논문집
    • /
    • pp.383-389
    • /
    • 1999
  • This paper is a study on the improvement effects by quick lime pile through theoretical analysis and in-situ construction test. Effects of strength increase is studied to verify the improvement effects of soft ground arounding quick lime pile. First, engineering characteristics of quick lime and ground was studied, in the second place, laboratory test(consolidation test, triaxial compression test) and in-situ test(portable cone penetration test, vane test) were peformed for verification of strength increase of adjacent ground. Finally, the results of in-situ test were compared with those of theorecal study. From in-situ test results, strength at 28th curing days(6.11-6.55t/㎡) was twice as great as strength before improvement(3.06t/㎡) and was slightly greater than theoretical value(4.95t/㎡).

  • PDF

동재하시험을 통한 긴장력이 도입된 콘크리트 충전 강관말뚝을 사용한 복합말뚝의 연직지지력 평가 (Estimation of Vertical Load Capacity of PCFT Hybrid Composite Piles Using Dynamic Load Tests)

  • 박노원;백규호
    • 한국지반환경공학회 논문집
    • /
    • 제20권3호
    • /
    • pp.31-38
    • /
    • 2019
  • PCFT말뚝의 하부에 PHC말뚝을 연결한 PCFT 복합말뚝에 대한 최적의 동재하시험 분석 방법을 도출하기 위하여 동일 현장에 시공된 강관 복합말뚝과 PCFT 복합말뚝에 대해 동재하시험을 실시한 후 CAPWAP분석 결과를 비교하였다. 그 결과 PCFT 복합말뚝에 대한 동재하시험 수행 시 변형률계와 가속도계는 상부 PCFT말뚝에서 강관을 제거한 후 내부 합성 PHC말뚝에 부착하는 것이 바람직하고, 이렇게 측정된 PCFT 복합말뚝의 입자 변위속도는 PHC말뚝 고유의 변형파 속도인 4,000m/sec과 동일하였다. 그리고 CAPWAP분석 시 PM과정을 통해 상부 PCFT말뚝의 재질을 PHC말뚝과 동일하게 하고 말뚝 단면적으로 콘크리트로 환산한 단면적을 사용했을 때 CAPWAP분석의 정확도가 가장 높은 것으로 나타났다.

수평재하시험 결과를 이용한 말뚝의 수평방향 지반반력계수 예측에 관한 연구 (A Study on Prediction of the Coefficient of Horizontal Subgrade Reaction for Pile Using Lateral Pile Loading Test Results)

  • 천병식;서덕동;이용재
    • 한국지반환경공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.15-24
    • /
    • 2006
  • 본 연구에서는 수평재하시험과 공내수평재하시험 결과를 이용하여 지반반력계수를 각각 분석하였다. 또한 이들 값과 수평재하시험 실시 위치에서의 N치를 이용하여 도로교표준시방서, 일본토목학회, Hukuoka식, 일본도로협회 제안식으로 산정한 수평방향 지반반력계수를 비교 및 분석하여 제안식별 적용성을 평가하고자 하였다. 수평방향 지반반력계수 산정시 지반의 변형계수가 큰 영향을 미치는 것으로 볼 때 합리적인 지반의 변형계수 산정이 매우 중요하며, 제안식별 변형계수 적용에 대해 재하시험 결과를 이용하여 검토하였다. 특히 공내수평재하시험 결과를 이용하여 지반반력계수를 산정하는 방법은 수평변위를 고려할 수 없는 등의 문제점이 있는 것으로 나타나 사질토 지반의 수평방향 지반반력계수 산정시 말뚝의 직경과 수평변위를 고려할 수 있는 식을 제안하였으며, 아울러 N치를 이용한 지반의 변형계수를 고려하는 제안식에 대해서는 수평재하시험과 비교하여 지반의 변형계수 추정식을 제안하였다.

  • PDF

모래다짐말뚝(SCP)에 의한 매립지반의 액상화저감효과 평가 (Evaluation of Liquefaction Remediation of Reclaimed Land by Sand Compaction Pile)

  • 김종국;손형호;윤원섭;채영수;최인걸
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1678-1688
    • /
    • 2008
  • In this study, dredging reclamation ground were performed to evaluate the ground improvement and liquefaction reduction effect with the result that standard penetration test(SPT) and piezo penetration test(CPT) before and after of improvement. Especially, the estimate center of the pile and factor of liquefaction safety to the position of ground around with the pile presented improvement of compaction for improved compaction of dredging reclamation ground.

  • PDF