• Title/Summary/Keyword: In-phase component

Search Result 1,376, Processing Time 0.027 seconds

Effects of Input Harmonics, DC Offset and Step Changes of the Fundamental Component on Single-Phase EPLL and Elimination

  • Luo, Linsong;Tian, Huixin;Wu, Fengjiang
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1085-1092
    • /
    • 2015
  • In this paper, the expressions of the estimated information of a single-phase enhanced phase-locked loop (EPLL), when input signal contains harmonics and a DC offset while the fundamental component takes step changes, are derived. The theoretical analysis results indicate that in the estimated information, the nth-order harmonics cause n+1th-order periodic ripples, and the DC offset causes a periodic ripple at the fundamental frequency. Step changes of the amplitude, phase angle and frequency of the fundamental component cause a transient periodic ripple at twice the frequency. These periodic ripples deteriorate the performance of the EPLL. A hybrid filter based EPLL (HF-EPLL) is proposed to eliminate these periodic ripples. A delay signal cancellation filter is set at the input of the EPLL to cancel the DC offset and even-order harmonics. A sliding Goertzel transform-based filter is introduced into the amplitude estimation loop and frequency estimation loop to eliminate the periodic ripples caused by the residual input odd-order harmonics and step change of the input fundamental component. The parameter design rules of the two filters are discussed in detail. Experimental waveforms of both the conventional EPLL and the proposed HF-EPLL are given and compared with each other to verify the theoretical analysis and advantages of the proposed HF-EPLL.

Atmospheric Concentrations of PAHs in the Vapor and Particulate Phases in Chongju

  • Park, Seung-Shik;Kim, Young-J.;Kang, Chang-H.;Cho, Sung-Yong;Kim, Tae-Young;Kim, Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E2
    • /
    • pp.57-68
    • /
    • 2006
  • Four intensive seasonal sampling campaigns between October 1998 and October 1999 were undertaken at an urban site of Chongju, in which polyurethane foam (PUF) sampler was used to collect particulate- and vapor-phase polycyclic aromatic hydrocarbons (PAHs). The contribution to total (particulate+vapor) PAH concentration by the vapor phase component exceeded the particulate phase contribution by factor of ${\sim}2.6$. Summed concentrations of phenanthrene (30.9%), pyrene (16.6%), naphthalene (11.3%) and fluoranthene (11.0%) account for significant amounts of the vapor-phase, while chrysene (12.5%), benzo[b]fluoranthene (11.6%), indeno[123-cd]pyrene (9.9%), benzo[ghi]perylene (9.5%), benzo[k]fluoranthene (9.4%), pyrene (8.9%), and benzo[a]pyrene (8.3%) are found to be the most common PAH compounds in the particulate phase. The results from application of principal component analysis to particulate-phase PAH data demonstrate that a combination of PAH and $PM_{2.5}$ inorganic data is a more powerful tracer of emission sources than PAH species data alone. Particulate-phase PAH species were found to be associated predominantly with emissions from diesel engine vehicles and incineration.

A Study on Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-phase Grid-connected Inverters (단상 계통연계형 인버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구)

  • Hwang, Seon-Hwan;Hwang, Young-Gi;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.68-76
    • /
    • 2014
  • This paper presents an offset error compensation algorithm for the accurate phase angle of the grid voltage in single-phase grid-connected inverters. The offset error generated from the grid voltage measurement process cause the fundamental harmonic component with grid frequency in the synchronous reference frame phase lock loop (PLL). As a result, the grid angle is distorted and the power quality in power systems is degraded. In addition, the dq-axis currents in the synchronous reference frame and phase current have the dc component, first and second order ripples compared with the grid frequency under the distorted grid angle. In this paper, the effects of the offset and scaling errors are analyzed based on the synchronous reference frame PLL. Particularly, the offset error can be estimated from the integrator output of the synchronous reference frame PLL and compensated by using proportional-integral controller. Moreover, the RMS (Root Mean Square) function is proposed to detect the offset error component. The effectiveness of the proposed algorithm is verified through simulation and experiment results.

A Case Study of Active Workflow Component Architecture on Constraints Based (제약식 기반의 능동적 워크플로우 컴포넌트 아키텍쳐 사례 연구)

  • Seo, Jang-Hoon;Shim, Sang-Yong;Lee, Kun-Hyuk;Park, Myeong-Kyu
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.415-426
    • /
    • 2006
  • Many technical and nontechnical issues hinder enterprise wide workflow management. The most significant technical issue is the inability to deal with the heterogeneity among users, workflow types, and WFMSs. Not all users demand the same workflow functionality, so user interfaces of different levels of sophistication are required. Because workflow types cannot always be fully predefined, they often need to be adjusted or extended during execution. Unlike relational database management systems, however, each WFMS often has differing workflow metamodels. This leads to incompatibility between WFMSs, making integration into an environment comprising many heterogeneous WFMSs a troublesome and sometimes impossible task. Current Workflow system consists mainly of Database system. It contains some problems like that the integration relationship among system processes cant be expressed properly. This research has been focused on two phases that should be considered in the Workflow system. First of all, the first phase is the analysis phase; one of its role is to figure out independent execution task unit(Workflow component). The second phase is design phase that provides with the framework to execute these task units actively. The Workflow component extraction method in the analysis phase uses a analysis method called C-C Net and, in the design phase, the architecture that makes the these Workflow component executed actively is provided. Through this research, each process is divided into a task unit and more effective Workflow system could be formed by executing these units actively. Current system layer calls task units, on the other hand, the Workflow system this research implemented provides with the architecture that places a layer between them that controls task units actively.

  • PDF

Analysis of Decoupling Method in DQ Transform-based for Grid Connected Inverter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.924-925
    • /
    • 2008
  • There are many types of grid-connected inverter controllers, PI controller based is the most popular methods. But, a common PI control is produced zero-steady state error and phase delay in sinusoidal reference. Synchronous reference frame or DQ transform based controller is capable for reducing both of zero-steady state error and phase delay is. But DQ transform based controller has cross-coupling component which difficult to analyze the system in single phase model. In this paper, to obtained single phase model of the system, DQ transform based controller is analyzed in two techniques. The first is by neglecting cross-coupling. The second is eliminated cross-coupling component by decoupling method. By these two techniques, single phase model is obtained. Then, the single phase model is analyzed to evaluate its performance in stability and frequency response, through Root Locus and Bode diagram, respectively. MATLAB and PSIM simulation is used to verify the analysis. Simulation result is shown; cross-coupling component has no significant influent to the controller.

  • PDF

A Study on Change of Texture During Thermal Cycling in Cu-Zn-AI Shape Memory Alloy (Cu-Zn-AI 형상기억 합금의 열사이클에 따른 집합조직의 변화에 관한 연구)

  • Hong, D.W.;Park, Y.K.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.5 no.3
    • /
    • pp.179-185
    • /
    • 1992
  • The shape memory effect results from the martensite transfomation of each individual grain. Thus it is necessary to study the texture and its variation. In this study the change of texture during thermal cycling and it's effect on shape memory ability are investigated. The major component of the rolling texture in the parent phase is identified (001) [110], and minor components are (112) [110], (111) [112], {hkl}<100> fiber texture is developed at $45^{\circ}$ from rolling direction. In the case of martensite phase, it is estimated that the major component is (011) [100] and the minor components are (105) [501], (010) [101] and (100) [001]. According to thermal cycling. severity of texture, especially (001) [110] component in parent phase and (011) [100] component in martensite phase are increased. The shape memory ability is increased with increase of thermal cycles and also increased as the direction of specimen approach to $45^{\circ}$ from rolling direction. After first thermal cycling the temperature of transformation can be define clearly and Ms and As are raised by thermal cycling.

  • PDF

The Study on Detecting Scheme of Voltage Sag using the Two Difference Voltage (이중 차 전압을 이용한 전압 새그 검출 기법에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.65-73
    • /
    • 2014
  • In this paper, the detection scheme of the voltage variation using a two difference voltage is proposed. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on a d-q transformation using an all-pass filter (APF). The APF generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the APF cannot generate the virtual q-axis voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage around the zero crossing is not enough to detect the voltage sag. Therefore, the new detection scheme using the two difference voltage which can detect the sag around the zero crossing voltage is proposed.

Assessment of ECCMIX component in RELAP5 based on ECCS experiment

  • Song, Gongle;Zhang, Dalin;Su, G.H.;Chen, Guo;Tian, Wenxi;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.59-68
    • /
    • 2020
  • ECCMIX component was introduced in RELAP5/MOD3 for calculating the interfacial condensation. Compared to other existing components in RELAP5, user experience of ECCMIX component is restricted to developmental assessment applications. To evaluate the capability of the ECCMIX component, ECCS experiment was conducted which included single-phase and two-phase thermal mixing. The experiment was carried out with test sections containing a main pipe (70 mm inner diameter) and a branch pipe (21 mm inner diameter) under the atmospheric pressure. The steam mass flow in the main pipe ranged from 0 to 0.0347 kg/s, and the subcooled water mass flow in the branch pipe ranged from 0.0278 to 0.1389 kg/s. The comparison of the experimental data with the calculation results illuminated that although the ECCMIX component was more difficult to converge than Branch component, it was a more appropriate manner to simulate interfacial condensation under two-phase thermal mixing circumstance, while the two components had no differences under single-phase circumstance.

A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1513-1525
    • /
    • 2016
  • Rapid and accurate phase synchronization is critical for the reliable control of grid-tied inverters. However, the commonly used software phase-locked loop methods do not always satisfy the need for high-speed and accurate phase synchronization under severe grid imbalance conditions. To address this problem, this study develops a novel open-loop phase locking scheme based on a synchronous reference frame. The proposed scheme is characterized by remarkable response speed, high accuracy, and easy implementation. It comprises three functional cascaded blocks: fast orthogonal signal generation block, fast fundamental-frequency positive sequence component construction block, and fast phase calculation block. The developed virtual orthogonal signal generation method in the first block, which is characterized by noise immunity and high accuracy, can effectively avoid approximation errors and noise amplification in a wide range of sampling frequencies. In the second block, which is the foundation for achieving fast phase synchronization within 3 ms, the fundamental-frequency positive sequence components of unsymmetrical grid voltages can be achieved with the developed orthogonal signal construction strategy and the symmetrical component method. The real-time grid phase can be consequently obtained in the third block, which is free from self-tuning closed-loop control and thus improves the dynamic performance of the proposed scheme. The proposed scheme is adaptive to severe unsymmetrical grid voltages with sudden changes in magnitude, phase, and/or frequency. Moreover, this scheme is able to eliminate phase errors induced by harmonics and random noise. The validity and utility of the proposed scheme are verified by the experimental results.

Fast Extraction of Symmetrical Components from Distorted Three-Phase Signals Based on Asynchronous-Rotational Reference Frame

  • Hao, Tianqu;Gao, Feng;Xu, Tao
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1045-1053
    • /
    • 2019
  • A symmetrical component decomposition scheme utilizing the characteristics of the asynchronous rotational reference frame transformation is proposed in this paper for the extraction of the positive and negative sequence components of distorted three-phase grid voltages. The undesired frequency component can be removed using a specially designed series coordinate transformation and half-cycle delays, where the delay can be controlled by adjusting the frequency of the rotating reference frame. The extracted symmetrical component can then be compensated based on the applied coordinated transformation. The dynamic response of the proposed algorithm is improved when compared to that of conventional methods. The effectiveness of the proposed algorithm is verified by simulation and experimental results.