• 제목/요약/키워드: In-motion alignment

검색결과 160건 처리시간 0.031초

Positional uncertainties of cervical and upper thoracic spine in stereotactic body radiotherapy with thermoplastic mask immobilization

  • Jeon, Seung Hyuck;Kim, Jin Ho
    • Radiation Oncology Journal
    • /
    • 제36권2호
    • /
    • pp.122-128
    • /
    • 2018
  • Purpose: To investigate positional uncertainty and its correlation with clinical parameters in spine stereotactic body radiotherapy (SBRT) using thermoplastic mask (TM) immobilization. Materials and Methods: A total of 21 patients who underwent spine SBRT for cervical or upper thoracic spinal lesions were retrospectively analyzed. All patients were treated with image guidance using cone beam computed tomography (CBCT) and 4 degrees-of-freedom (DoF) positional correction. Initial, pre-treatment, and post-treatment CBCTs were analyzed. Setup error (SE), pre-treatment residual error (preRE), post-treatment residual error (postRE), intrafraction motion before treatment (IM1), and intrafraction motion during treatment (IM2) were determined from 6 DoF manual rigid registration. Results: The three-dimensional (3D) magnitudes of translational uncertainties (mean ${\pm}$ 2 standard deviation) were $3.7{\pm}3.5mm$ (SE), $0.9{\pm}0.9mm$ (preRE), $1.2{\pm}1.5mm$ (postRE), $1.4{\pm}2.4mm$ (IM1), and $0.9{\pm}1.0mm$ (IM2), and average angular differences were $1.1^{\circ}{\pm}1.2^{\circ}$ (SE), $0.9^{\circ}{\pm}1.1^{\circ}$ (preRE), $0.9^{\circ}{\pm}1.1^{\circ}$ (postRE), $0.6^{\circ}{\pm}0.9^{\circ}$ (IM1), and $0.5^{\circ}{\pm}0.5^{\circ}$ (IM2). The 3D magnitude of SE, preRE, postRE, IM1, and IM2 exceeded 2 mm in 18, 0, 3, 3, and 1 patients, respectively. No association were found between all positional uncertainties and body mass index, pain score, and treatment location (p > 0.05, Mann-Whitney test). There was a tendency of intrafraction motion to increase with overall treatment time; however, the correlation was not statistically significant (p > 0.05, Spearman rank correlation test). Conclusion: In spine SBRT using TM immobilization, CBCT and 4 DoF alignment correction, a minimum residual translational uncertainty was 2 mm. Shortening overall treatment time and 6 DoF positional correction may further reduce positional uncertainties.

기능적 전기자극에 대한 고찰 (The Review of Functional Electrical Stimulation)

  • 박규현;김선규;정현애;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제13권2호
    • /
    • pp.399-405
    • /
    • 2001
  • Attainment of the goals of functional electrical stimulation(FES) applications such as strengthening of muscle, increasing muscular endurance, improvement in joint range of motion or the reduction of spasticity does not insure that patients will be able to produce voluntary muscle contraction sufficient to maintain posture or produce purposeful movements. In many patients who have sustained CNS damage, the control exerted by higher nervous system center over muscle contraction may impaired. In Searched patients, a variety of advanced therapeutic exercise techniques have been employed traditionally to facilitate the return of controlled functional muscular activity or maintain postural alignment until recovery from dysfunction occurs Among the most common clinical applications of FES for functional muscle contraction is as a substitute for static or dynamic orthotic devices

  • PDF

자동 광섬유 정렬 장치의 설계 및 제작에 관한 연구 (A Study on the Design and Development of Automatic Optical Fiber Aligner)

  • 김병희;엄철;최영석
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.241-249
    • /
    • 2002
  • Optical fiber is indispensable for optical communication systems that transmit large volumes of data at high speed, but super precision technology in sub-micron units is required for optical axis adjustment. We developed the automatic optical fiber by image processing and automatic loading system. we have developed 6-axis micro stage system for I/O optical fiber arrays, the initial automatic aligning system software for a input optical array by the image processing technique, fast I/O-synchronous aligning strategy, the automatic loading/unloading system and the automatic UV bonding mechanism. In order to adjust the alignment it used on PC based motion controller, a $10{\mu}m$ repeat-detailed drawing of automatic loading system is developed by a primary line up for high detailed drawing. Also, at this researches used the image processing system and algorithm instead of the existing a primary hand-line up and fiber input array and waveguide chip formed in line by automatic.

  • PDF

원통형 커패시턴스 센서를 이용한 초정밀 공기 주축의 회전오차 측정

  • 김해일;박상신;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.637-642
    • /
    • 1995
  • For measuring the error motion of ultra-precision spindle, eliminating the geometric errors is a must. Unless it is achieved, geometric errors will be dominant in data. Here, the roundness error and alignment error between spindle and sensor are to be removed. That's because typical error range of such spindle is muchless than geometric one. A capacitive transducer of cylidricalshape was developed, which takes full advantage of the spatial-averaging effect by using large area compared tpo the geometric error. This idea was first proposed by Chapman and here it is modified for better performance with nomical gap of 50 .mu. m and with newly designed guards which encompass the respective sensor to rectify the electrical field distribution in good shape. The measurement system is made to get the orbit of Ultra-Precision Air Spindle which is supposed to have its runout under 1 .mu. m. The Calibration data of this sensor is presented and the spindle orbit from 2000rpm to 5500rpm is showed. It is quite reasonable to use this sensor in the range of 60 .mu. m with an accuracy of several tens of nm.

항공기 탑재용 카메라 위치출력오차 측정방안 연구 (A Study of Test Method for Position Reporting Accuracy of Airborne Camera)

  • 송대범;윤용은
    • 한국군사과학기술학회지
    • /
    • 제16권5호
    • /
    • pp.646-652
    • /
    • 2013
  • PRA(Position Reporting Accuracy) for EO/IR(Electro-Optic/Infrared) airborne camera is an important factor in geo-pointing accuracy. Generally, rate table is used to measure PRA of gimbal actuated camera like EO/IR. However, it is not always possible to fix an EUT(Equipment for Under Test) to rate table due to capacity limit of the table on the size and weight of the object(EUT). Our EO/IR is too big and heavy to emplace on it. Therefore, we propose a new verification method of PRA for airborne camera and assess the validity of our proposition. In this method we use collimator, angle measuring instrument, 6 dof motion simulator, optical surface plate, leveling laser, inclinometer and poster(for alignment).

적외선 스펙트럼 측정방식을 이용한 윤활유의 변화연구 (Infrared Spectroscopic Investigation of Lubricants under Shear)

  • 안영재
    • Tribology and Lubricants
    • /
    • 제3권2호
    • /
    • pp.44-49
    • /
    • 1987
  • Molecular alignment has been postulated as influencing non-Newtonian behavior of liquid lubricants containing various additives. Four blended lubricants, two synthetic and two mineral were analyzed by FTIR spectroscopy. All of the lubricants exhibited polarization changes in their infrared emission spectra at 60$\circ$C under shear. For this work a special mockup journal bearing was constructed to seperate load and shear effects. At a temperature of 100$\circ$C polarization by shear was always reduced, presumably by Browninn motion. This work should be useful in pointing to the shear-sensitive factors. The presence of of a VI improving additive is manifested by the independence of the infrared emissivity with temperature at several wavelengths; a lubricant without a VI improver generally shows a decrease of emissivity at higher temperature.

리스프랑 관절 손상 (Lisfranc Joint Injury)

  • 이명진
    • 대한족부족관절학회지
    • /
    • 제20권3호
    • /
    • pp.106-111
    • /
    • 2016
  • The Lisfranc joint complex is an anatomical association of many bones and articulation, restrained by an even more complex network of ligaments, capsules, and fascia, which must work in concert to provide normal and painless motion. Careful diagnostic workup with high-quality radiographs and computed tomography of the foot are used to diagnose injuries and fractures of this complex. We have to understand the normal anatomy and injury mechanism in order to appropriately treat Lisfranc injuries. Good results have been associated with anatomic reductions of all bones, which was achieved with restoration of proper alignment.

신체질량지수, 하지관절의 모멘트, 지면반발력이 무릎외반슬에 미치는 영향 (The Effect of Genu Valgum on the Body Mass Index, Moment of Lower Limb Joints, Ground Reaction Force)

  • 이용선
    • 한국운동역학회지
    • /
    • 제25권3호
    • /
    • pp.257-263
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the effect of genu valgum on the body mass index, movement of lower limb joints, and ground reaction force. Methods : Gait patterns of 30 college students with genu valgum were analyzed and the static Q angle of the femur was measured for selecting genu valgum of the subjects. To analyze the kinetic changes during walking, the six-camera Vicon MX motion analysis system was used. The subjects were asked to walk 12 meters using the more comfortable walking method for walking. After they walked 12 meters more than 10 times, their most natural walking patterns were chosen three times and analyzed. Results : As a result of measuring a relationship between genu valgum and Q-angle, as the Q-angle increases, it showed a genu valgum also increased. Body Mass Index showed a significant difference between the groups was higher in the genu valgum group.(p<.001). The analysis result showed that genu valgum had a significant effect on the internal rotation moment in the hip joint(p<.05). Also, genu valgum had a significant effect on the internal rotation moment of the knee joint(p<.05). The comparative analysis of the Medial-Lateral ground reaction force in the genu valgum group showed a tendency to increase the medial ground reaction force(p<.05). The vertical ground reaction forces of the middle of the stance phase(Fz0) showed a significant increase in genu valgum group(p<.05), in particular the results showed a decrease in the early stance phase(p<.001). Conclusion : In conclusion, the change in body mass is considered to be made by proactive regular exercise for improvement of the genu valgum. In addition, the prevention of the deformation caused by secondary of the genu valgum in this study may be used as an indicator of the position alignment rehabilitation for structural and functional improvements. Applying a therapeutic exercise program for the next lap will require changes in posture alignment.

Effects of Mechanical Stimuli on the Cell Proliferation and Collagen Production on the Micropatterned Substrate

  • ;;;;;;;신정욱
    • 대한의생명과학회지
    • /
    • 제12권2호
    • /
    • pp.119-125
    • /
    • 2006
  • In relation to the tissue engineering, the cellular responses to the morphology of the scaffold surface are interesting topics. Human ligament fibroblasts (HLFs) were cultured on the micrpatterned silicone substrates subjected to cyclic stretch to simulate ligament motion. Groove and ridge width of silicone substrates was 10/50, 20/50, 20/10, and 20/20 ${\mu}m$ (groove/ridge ${\mu}m$) with a depth of $3{\mu}m$. Strain was applied over two days for 4 hours per day with a frequency of 0.5 Hz with the magnitudes of 4 or 8%. The purpose of this study was to evaluate ligament fibroblast alignment and cellular responses in relation to the pattern of microgrooved surface and stretching magnitude. Ligament fibroblasts in the microgrooved surface were elongated and aligned parallel to the microgrooves under no stretch. Uniaxial cyclic stretch induced cellular activities and their orientation rise in cellular response and the cells showed alignment and elongation perpendicular to the direction of the stretch. Biochemical analyses showed that the best cellular response was found on the $20/50{\mu}m$ under 8% stretch. The surface morphology and mechanical stretching were found to contribute to increase of proliferation, collagen production.

  • PDF

동태손상(動態損傷) 증후군(症候群)에 관한 연구 현황 고찰 (A Review Study on Movement System Impairment Syndromes)

  • 김정균;김현호;서재호;김동원;박영재;박영배
    • 대한한의학회지
    • /
    • 제33권1호
    • /
    • pp.79-89
    • /
    • 2012
  • Objectives: Sahrmann, an American physical therapist, has developed a set of movement-related diagnoses on musculoskeletal pain syndromes (MPS). We reviewed articles for studies of objectification and quantification of Oriental medicine diagnosis system about MPS. Methods: The authors reviewed a total of 12 studies found on PubMed to obtain movement system impairment (MSI)-based classification categories. Results: The MSI system has been developed for objectification and quantification of physical therapists' MPS diagnoses. The MSI system of classification is based on the basic premise that loss of precise movement is the result of specific repetitive movements and positions in everyday life. The MSI system defines 8 categories in the shoulder region, 5 in the lumbar region, and 7 in the knee region. Treatment involves (1) educating the person about the specific directions of alignment and movement that appear to be contributing to the musculoskeletal problem, (2) modifying the direction - specific alignment and movement patterns during daily activities, and (3) exercises to address the impairments. Conclusions: The authors propose that MSI studies could help to advance an Oriental medical diagnosis system on musculoskeletal pain syndromes, because MSI shares similarity with Oriental medicine in terms of holism, views of constant motion, and mi-byung (subhealth) treatment.