• Title/Summary/Keyword: In-line monitoring

Search Result 1,355, Processing Time 0.025 seconds

Implementation of Wireless PGN Analyzer for ISOBUS network

  • Tumenjargal, Enkhbaatar;Badarch, Luubaatar;Lee, Kangsan;Ham, Woonchul;Doopalam, Enkhzul;Togooch, Amartuvshin
    • Smart Media Journal
    • /
    • v.4 no.2
    • /
    • pp.46-54
    • /
    • 2015
  • Communication between ECUs (Electronic Control Units) in agricultural machineries tends to use IS011783 widely, that is PGN (Parameter Group Number) based communication protocol lays on CAN protocol by altering its identifier part. Messages in line are transferred and received between ECUs according to ISO11783 standard. This paper discusses about design of wireless monitoring system. We used an ARM Cortex-M3 microcontroller embedded development board and marvel8686 wireless module. The wireless ISOBUS monitoring system, attached to communication line, reads messages, interpret them, and display them on the screen in easily comprehendible form. It can be used to generate messages and monitor the traffic on physical bus systems. The monitoring system connected to ECUs, monitor and simulate real traffic of communication and functionality of the ECUs. In order to support our work, we have implemented the monitoring tool. The development consists of two parts: GUI of the application and firmware level programming. Hence the monitoring system is attached to the communication line and equipped by Wi-Fi module; farmer/dispatcher in a farm monitors all messages in communication line on personal computer and smart device.

Feasibility of RF Sensor Application for On-line Monitoring of Tomato Paste Processing (토마토 패이스트 가공공정의 온라인 모니터링용 RF 센서의 활용 가능성)

  • Kim, Seong-Min;Garvey, Casey;Leary, Thomas;McCarthy, Michael
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.410-415
    • /
    • 2008
  • On-line monitoring of fresh tomato paste processing was done using two radio frequency (RF) sensors resonant at 85 and 110 MHz. Fresh tomato juice with soluble solid content of about $5^{\circ}Brix$ was evaporated up to $23^{\circ}Brix$ and diluted down to about $5^{\circ}Brix$ again with a pilot scale evaporator. The RF sensors were installed in a processing pipe and monitored. The pastes at a specific $^{\circ}Brix$ level were sampled and analyzed for physical properties such as soluble solid content and viscosity. The relationships between sensor outputs and measured physical properties were analyzed. Analysis results showed RF sensor is feasible to apply on-line monitoring of tomato paste processing.

On-line Monitoring of IPTG Induction for Recombinant Protein Production Using an Automatic pH Control Signal

  • Hur Won;Chung Yoon-Keun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.10 no.4
    • /
    • pp.304-308
    • /
    • 2005
  • The response of IPTG induction was investigated through the monitoring of the alkali consumption rate and buffer capacity during the cultivation of recombinant E. coli BL21 (DE3) harboring the plasmid pRSET-LacZ under the control of lac promoter. The rate of alkali consumption increased along with cell growth, but declined suddenly after approximately 0.2 h of IPTG induction. The buffer capacity also declined after 0.9 h of IPTG induction. The profile of buffer capacity seems to correlate with the level of acetate production. The IPTG response was monitored only when introduced into the mid-exponential phase of bacterial cell growth. The minimum concentration of IPTG for induction, which was found out to be 0.1 mM, can also be monitored on-line and in-situ. Therefore, the on-line monitoring of alkali consumption rate and buffer capacity can be an indicator of the metabolic shift initiated by IPTG supplement, as well as for the physiological state of cell growth.

Development and Application of Distributed Multilayer On-line Monitoring System for High Voltage Vacuum Circuit Breaker

  • Mei, Fei;Mei, Jun;Zheng, Jianyong;Wang, Yiping
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.813-823
    • /
    • 2013
  • On-line monitoring system is important for high voltage vacuum circuit breakers (HVCBs) in operation condition assessment and fault diagnosis. A distributed multilayer system with client/server architecture is developed on rated voltage 10kV HVCB with spring operating mechanism. It can collect data when HVCB switches, calculate the necessary parameters, show the operation conditions and provide abundant information for fault diagnosis. Ensemble empirical mode decomposition (EEMD) is used to detect the singular point which is regarded as the contact moment. This method has been applied to on-line monitoring system successfully and its satisfactory effect has been proved through experiments. SVM and FCM are both effective methods for fault diagnosis. A combinative algorithm is designed to judge the faults of HVCB's operating mechanism. The system's precision and stability are confirmed by field tests.

A Study on the Quality Estimation of Resistance Spot Welding Using Hidden Markov Model (은닉 마르코프 모델을 이용한 저항 점용접 품질 추정에 관한 연구)

  • 김경일;최재성
    • Journal of Welding and Joining
    • /
    • v.20 no.6
    • /
    • pp.45-45
    • /
    • 2002
  • This study is a middle report on the development of intelligent spot welding monitoring technology applicable to the production line. An intelligent algorithm has been developed to predict the quality of welding in real time. We examined whether it is effective or not through the In-Line and the Off-Line tests. The purpose of the present study is to provide a reliable solution which can prevent welding defects in production site. In this study, the process variables, which were monitored in the primary circuit of the welding, are used to estimate the weld quality by Hidden Markov Model(HMM). The primary dynamic resistance patterns are recognized and the quality is estimated in probability method during the welding. We expect that the algorithm proposed in the present study is feasible to the applied in the production sites for the purpose of in-process real time quality monitoring of spot welding.

A Study on the Quality Estimation of Resistance Spot Welding Using Hidden Markov Model (은닉 마르코프 모델을 이용한 저항 점용접 품질 추정에 관한 연구)

  • 김경일;최재성
    • Journal of Welding and Joining
    • /
    • v.20 no.6
    • /
    • pp.769-775
    • /
    • 2002
  • This study is a middle report on the development of intelligent spot welding monitoring technology applicable to the production line. An intelligent algorithm has been developed to predict the quality of welding in real time. We examined whether it is effective or not through the In-Line and the Off-Line tests. The purpose of the present study is to provide a reliable solution which can prevent welding defects in production site. In this study, the process variables, which were monitored in the primary circuit of the welding, are used to estimate the weld quality by Hidden Markov Model(HMM). The primary dynamic resistance patterns are recognized and the quality is estimated in probability method during the welding. We expect that the algorithm proposed in the present study is feasible to the applied in the production sites for the purpose of in-process real time quality monitoring of spot welding.

Comparison of properties at Fossil Power Plant by On-Line Real Time Performance Monitoring System (On-Line 실시간 성능감시 시스템을 이용한 화력발전소 운전 Parameter 값 비교분석)

  • Jung, Hoon;Park, Doo-Yong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3501-3505
    • /
    • 2007
  • As the power plant industry has been changed into competition structure, power generation companies do more with less by increasing capacity and lowering operation costs. In order to achieve this goals, an on-line real-time performance monitoring system has been needed to introduced to fossil power plant. The system represents a suite of related software modules which consist of on-line data, and on-line performance modules. This system can help the plant staff get the most out of their facilities by continuously monitoring deviations in equipment performance and the impact on those deviations on plant power, heat rate and operating cost. This paper shows the comparison of design value with acceptance test and current(measured) value.

  • PDF

On-line Condition Monitoring for Electric Equipments (전력 설비 시스템의 온라인 감시)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.103-105
    • /
    • 2008
  • In, this paper, we consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PO) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PO testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PO measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

Reliability Improvement of Insulation Diagnosis Using the Hydro-Generator On-Line Partial Discharge Monitoring System (수력발전기 On-line 부분방전 측정 시스템을 이용한 절연상태 진단의 신뢰성 향상)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Lim, Jae-Il;Park, Ji-Kun;Kwak, Won-Ku;Lee, Jae-Heung;Shin, Jae-Pil;Shin, Byoung-Chol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.469-475
    • /
    • 2009
  • Accident dangerousness of domestic hydro power generators which are operated in Korea is on the increase because of use at the long term. On this, the Off-line diagnosis techniques developed to the On-line by continued domestic technical development since 2000. Especially, On-line insulation diagnosis of domestic hydro power generator is possible by localization of partial electric discharge sensor and On-line insulation diagnosis system. This paper shows the diagnosis result that is applied localized Ceramic Coupler and PDMS-HG(Partial Discharge Monitoring System for Hydro Generator) at four Chung-ju hydro Generator used for 25 years. Particularly, the confidence of insulation diagnosis is improved by using high frequency filter and sampling the partial discharge signals which occur in site. For reviewing the confidence of On-Line insulation diagnosis system, we measured the outside noises and partial discharge signals during practical operation by using the partial discharge diagnosis system of the Full A/D process. And we reviewed the confidence of the On-Line insulation diagnosis system by comparing and analyzing these data.

Monitoring of Cleanliness Level in Hydraulic Systems: Obtaining Reliable On-Line data

  • Hong, Jeong-Hee;Day, Mike
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.28-38
    • /
    • 2012
  • Monitoring of system cleanliness levels and counting of particulate contaminant are fundamental to achieving hydraulic system reliability as any departure from the specified cleanliness level is often a precursor to future failures. On-line monitoring of cleanliness levels has the advantage of giving data both very quickly and accurately as environmental influences are eliminated. In this way, corrective actions can be promptly implemented. Most on-line instruments are sensitive to system conditions to a greater or lesser extent, but Automatic Particle Counters (APCs) working on light extinction principles are especially sensitive to the presence of optical interfaces caused by such conditions as fluid mixtures, emulsions, free water and air bubbles. These conditions give erroneous data and can result in drawing incorrect conclusions, wasting maintenance time and ultimately, reduced user confidence in cleanliness monitoring. This paper describes such conditions and shows how the correct selection of the analysis technique can result in reliable cleanliness level data.