• Title/Summary/Keyword: In-line monitoring

Search Result 1,359, Processing Time 0.029 seconds

Practical Applications of Multi-Agent Transformer Condition Monitoring (다수 변압기의 온라인 모니터링을 위한 실제 적용)

  • Yun, Ju-Ho;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.96-99
    • /
    • 2008
  • On-line condition monitoring is a useful tool for maintaining and extending the longevity of power transformers. An intelligent diagnostic system is desirable for operational safety and reliability. Bringing these concepts together results in a powerful support tool for engineers, reducing the volume of data to deal with, and making the data more meaningful. This paper describes how a multi-agent system for diagnosing the cause of transformer partial discharge activity was coupled with a method of UHF partial discharge monitoring, creating an on-line condition monitoring system. The challenges presented by the on-site environment are discussed, along with the implications for the complete system.

  • PDF

Dielectric Cure Monitoring for Glass/Polyester Prepreg Composites (유리섬유/폴리에스터 복합재료를 위한 유전 경화 모니터링)

  • Kim, Hyoung-Geun;Kim, Jin-Kook;Lee, Dai-Gil
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.797-803
    • /
    • 2001
  • The on-line cure monitoring of fiber reinforced thermosetting resin matrix composite material was performed for the better quality and productivity during manufacturing. Since the dissipation factor measured by dielectrometry method is dependent on the degree of cure and temperature of resin, in this study, a new method to obtain the degree of cure during on-line cure monitoring for glass/polyester composites was developed by employing a combination function of the temperature and the dissipation factor. Two sensor signals from a K-type thermocouple and an interdigitated dielectric sensor were processed during curing process under various cure cycles. The DSC (Differential Scanning Calorimetry) data was also used for the reference of degree of cure.

  • PDF

Analysis for the dynamic responses of pantograph-overhead contact line coupled system by using a condition monitoring system (상태감시시스템을 이용한 팬터그래프-전차선로 동특성 분석에 관한 연구)

  • Cho, Yong-Hyeon;Park, Young;Lee, Ki-Won;Kwon, Sam-Young;Park, Hyun-June
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.778-781
    • /
    • 2008
  • The aim of this paper is to analyze the dynamic responses of pantograph-overhead contact line coupled system by using a condition monitoring system. The monitoring items are strain, vertical displacement and acceleration of a contact wire. Both strain and vertical displacement in the contact wire depends on uplift force and train velocity. Measurement of acceleration shows that the passage of the pantograph gives an impact force to a hard point on a contact wire.

  • PDF

On-Line Condition Monitoring for Rotating Machinery Using Multivariate Statistical Analysis (다변량 통계 분석 방법을 이용한 회전기계 이상 온라인 감시)

  • Kim, Heung-Mook;Lim, Eun-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1108-1113
    • /
    • 2000
  • A condition monitoring methodology for rotating machinery is proposed based on multivariate statistical analysis. The CMS usually are using the vibration signal amplitude such as acceleration RMS, peak and velocity RMS to detect machine faults but the information is not so enough that CMS cannot perform reliable monitoring. So new parameters are added such as shape factor, crest factor, kurtosis and skewness as time domain parameters and spectrum amplitude of rotating frequency, $2^{nd}$ harmonics and gear mesh frequency etc. as frequency domain parameters. Many parameters are combined to represent the machine state using the Hotelling's $T^2$ statistics. The proposed methodology is tested in laboratory and the on-line experiment has shown that the proposed methodology offers a reliable monitoring for rotating machinery.

  • PDF

Dynamic Bandwidth Allocation Algorithm of XG-PON using Traffic Monitoring (Traffic Monitoring 방식의 XG-PON 동적대역할당 방법)

  • Hong, Sung Hark;Han, Man Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.705-706
    • /
    • 2014
  • This paper proposes a new dynamic bandwidth allocation algorithm for an XG-PON (10-Gbps-capable passive optical network) system. In the XG-PON system, an ONU (optical network unit) does not explicitly send it request to an OLT (optical line termination). The OLT monitors the upstream bandwidth usage of the ONU to estimate the request of the ONU. Then the OLT performs a dynamic bandwidth allocation process based on the estimated requests.

  • PDF

Dynamic Bandwidth Allocation Algorithm of XG-PON using Traffic Monitoring (Traffic Monitoring을 이용한 XG-PON 동적대역할당 알고리즘)

  • Hong, Sung Hark;Han, Man Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.152-153
    • /
    • 2014
  • This paper proposes a new dynamic bandwidth allocation algorithm for an XG-PON (10-Gbps-capable passive optical network) system in which an ONU (optical network unit) does not explicitly send its request to an OLT (optical line termination). To estimate the request of the ONU, the OLT monitors the upstream bandwidth usage of the ONU and periodically allocates a probe slot to the ONU.

  • PDF

Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현)

  • Kim, Dong-Hak;Kim, Young-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

A Study on the Detection of Tool Wear in Drilling of Hot-rolled High Strength Steel (열연강판의 드릴가공시 공구의 마멸량 검출에 관한 연구)

  • Sin, Hyeong-Gon;Kim, Tae-Yeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.148-154
    • /
    • 2001
  • Drilling is one of the most important operations in machining industry and usually the most efficient and economical method of cutting a hole in metal. From automobile parts to aircraft components, almost every manufactured product requires that holes are to be drilled for the purpose of assembly, creation of fluid passages, and so on. It is therefore desirable to monitor drill wear and hole quality changes during the hole drilling process. One important aspect in controlling the drilling process is monitoring drill wear status. A drill-wear monitoring system provides information about drill status. With the information, optimum planning for tool change is possible. And drill-wear monitoring system in needed to evaluated drilled hole quality and the wear of drill. Accordingly, this paper deals with an on-line drill wear monitoring system of the detection of tool wear with the computer vision and the area of the drill flank wear is analyzed quantitatively by the system.

  • PDF

On-line monitoring & control system in brewing process (맥주 공정의 자동계측 및 제어)

  • 백운화;고의찬;이광순;심정우
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.471-473
    • /
    • 1986
  • 맥주 제조 공정은 다음과 같이 이루어 진다. 담금공정-발효공정-저장공정-여과공정-제품공정, 이중 발효 및 저장 공정은 미생물이 관여하므로 균체의 생육과 제품 생산과의 관계등이 아주 예민하고 복잡하므르 Computer에 의한 자동 계측 및 제어는 효과적인 공정관리 수단이 되며, 또한 품질 향상과 균일화를 기대 할 수 있다. 이에 발효 및 저장조의 128 채널의 공정치 On-line monitoring, graphic display, disk 저장, 프린터로의 reporting 및 제어를 위한 hardware system 구성과 software를 개발하였다.

  • PDF

Recent research and technical trend of power cable system (전력 케이블의 최근 연구 및 기술 동향)

  • Kim, Dong-Uk;Choe, Myeong-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.616-618
    • /
    • 2000
  • This paper describes the recent research and technical trend of power cable system. Compact sizing with long length and large capacity is the main trend of the power cable. From the manufacturing process to the monitoring of the underground power line, various new techniques are being developed for reliability and high quality such as in-line monitoring system, triple common extrusion, PD measurement system, new type completion test, etc.

  • PDF