• 제목/요약/키워드: In-line measurement

검색결과 2,374건 처리시간 0.036초

접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석 (Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid)

  • 길형준;송길목;김영석;김종민
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

섬유강화 고분자 복합재의 사출성형에 있어서 웰드라인부의 섬유배향측정 (Measurement of the Fiber Orientation on Weld-Line Parts for Injection Molding of Fiber Reinforced Polymeric Composites)

  • 김혁;강명구;최유성;이동기;한길영;김이곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.265-270
    • /
    • 2000
  • Injection molding is a very important industrial process for the manufacturing of plastics objects. During an injection molding process of composites, the fiber-matrix separation and fiber orientation are caused by the flow of molten polymer/fiber mixture. As a result, the product tends to be nonhomogeneous and anisotropic. Hence, it is very important to clarify the relations between separation· orientation and injection molding conditions. So far, there is no research on the measurement of fiber orientation using image processing. In this study, the effects of fiber content ratio and molding condition on the fiber orientation-angle distributions are studied experimentally. Using the image processing method, the fiber orientation distribution of weld-line parts in injection-molded products is assessed. And the effects of fiber content and injection molding conditions on the fiber orientation functions are also discussed

  • PDF

지중선로 누전점 탐지를 위한 반주기 변조된 대지 펄스 측정 (The measurement of the half period modulated pulse on earth for detection of a underground electric leakage point)

  • 김재현;전정채;유재근
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5123-5127
    • /
    • 2011
  • 증가 추세인 지중 전력설비의 사고 예방과 유지 보수를 위한 기술 연구 개발 요구가 증가하고 있다. 지중선로의 경우 누전 불량의 점유율이 높고 보수도 어려워 정확한 누전점 위치의 탐지가 중요하다. 교류 송신파를 누전점을 가지는 지중선로에 인가하여 발생시킨 교류 대지전위를 측정하여 누전점의 위치를 찾는 방법은 송신파 특정 극성반주기에 교류 대지전위를 동기화하여 비교 판단하여야 한다. 송신파의 특정 극성의 반주기와 동기화하는 기존 방법을 설명하고, 송신파 반주기 변조된 대지 전위 측정 방식을 제안하고 소개하였다. 실험을 통하여 제안한 방식이 구현 가능함을 확인하였다.

고속열차 전기적 이선 특성 측정 방안 연구 (A Study of the Current Collection Characteristics Measurement Methodology for a High-Speed Train)

  • 조홍식;한인수;이태형;김석원;김영국
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3052-3058
    • /
    • 2011
  • A high-speed train is the system that the electric power is supplied through the overhead contact line and drives motors. In this case that the de-wiring beteen the overhead contact line and the pantograph of a high-speed train, the occasion that smooth power supply is not accomplished occurs sometimes. If the de-wiring occurs, the arc discharge may damage the overhead contact line or the pantograph, and the falling-off in power quality may cause the damage and malfunctioning of motor block. This paper presents the methodology that the arc discharge by de-wring between overhead line and pantograph is discriminated through measuring the PT and CT in the vehicle, and measures the current collection characteristics for a high speed train.

  • PDF

GPS를 이용한 가공송전선로 측량 (Surveying a 765kV Transmission Line Using GPS)

  • 정태호;김창호;윤영순;이안근;김정호;신태우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1091-1093
    • /
    • 1999
  • This paper discusses the surveying of a power transmission line using Real Time Kinematic(RTK) GPS technology. The use of RTK provides users with an accurate position at the moment in time. Application result of a 765kV transmission line surveying proved to be more accurate and efficient than using a traditional EDM (Electro-magnetic distance measurement) method. More, decrease in numbers of trees cut down which is a major cause of public discontents was achieved. Improvements in doing a surveying of a power transmission line using GPS is expected in the future.

  • PDF

Roentgenocephalometry에 의한 한국인 과로와 두부참조선과의 각도계측에 관한 연구 (A study on the Measurement of the Condyle Path Inclination in Relation to Skull Reference Lines by Roentgeno-Cephalometry)

  • 윤영윤
    • 대한치과의사협회지
    • /
    • 제11권2호
    • /
    • pp.134-138
    • /
    • 1973
  • The author measured and analyzed the condyle path inclinations of 25 normal Korean adults roentgeno-cephalometrically and following conclusions were obtained. In protrusive movement of mandible, the angle of condyle pation inclination in relation to 1) occlusal plane is 19.86±8.25, 2) Frankfort Horizontal plane is 28.32±8.56, 3) Camper line is 12.22±4.06, 4) Nasion-sella line is 36.80±8.54.

  • PDF

Development of AC Transmassion Line Audible Noise Prediction Formulas Using Evolutionary Computations

  • Yang, Kwang-Ho;Park, June-Ho;Hwang, Gi-Hyun;Kim, Jeong-Boo
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권6호
    • /
    • pp.116-122
    • /
    • 1997
  • The audible noise produced by corona discharge in high voltage transmission lines is the most important line design consideration. In this paper, more accurate and useful formulas for predicting the A-weighted audible noise during heavy and light rain in alternative current (AC) transmission lines are proposed through comparison with the existing formulas. The proposed formulas are developed by the applications of evolutionary computations (ECs) to audible noise data base from long-term measurement.

  • PDF

LCD 생산라인의 생산성 향상을 위한 초박형 유리진동 계측 시스템의 개발 (Development of a Thin Glass Vibration Measuring System for Productivity Improvement of LCD Manufacturing Line)

  • 오영교;이정욱;선주영;곽정석;원문철;이현엽
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.336-342
    • /
    • 2011
  • Recently, the LCD manufacturing industries try to maximize the productivity of LCD panels due to sharp increase in the market need of LCD display. Usually, the increase in manufacturing speed induces additional vibration of glasses and manufacturing machineries. This kind of vibration can induce bad effects on the manufacturing accuracy, and even can damage the glasses. The vibration signal of glass itself is very useful to predict the allowable maximum level of manufacturing speed. Therefore, it is necessary to measure the vibration of the glass itself and a very thin vibration measurement system attachable on the glass is needed. Since in some processes the glasses need to go through very thin gaps such as 2.5mm, We develop a glass vibration measurement system with the thickness of 1.3mm. The system measures the glass vibration using MEMS type accelerometers and store vibration data in a Nand-Flash memory. The performance of the develop system has been verified on a real LCD manufacturing line and the accuracy of vibration measurement is comparable with that of an accurate commercial vibration measurement system.

ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석 (Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

무용동작을 위한 밑위길이에 관한 연구 (A Study on the Crotch Length for Dance Movement)

  • 윤성화;이영주
    • 한국생활과학회지
    • /
    • 제11권1호
    • /
    • pp.45-58
    • /
    • 2002
  • The purpose of this study was to offer a more functional slacks by analyzing its crotch length. The result of the study were as follows : Regarding the feeling of wearing and appearance, the P2 b style which measures the crotch length starting from the waist line passing around the iliac spine was the most highly evaluated. This suggested that the functionality of dance movement was more influenced by the position of the waist line not by the crotch length measurement. Since the front and rear center lines of the crotch could not be flown if the waist line of slacks was positioned high, both the crotch and abdominal part might be clogged or tightened when dancers made large dance movements or bended their upper bodies forward. In conclusion, slacks for more functional dance movement should be manufactured focusing on the location of the waist line rather than on the crotch length.

  • PDF