• Title/Summary/Keyword: In-line measurement

Search Result 2,376, Processing Time 0.036 seconds

3D Precision Measurement of Scanning Moire Using Line Scan Camera (라인스캔 카메라를 이용한 3차원 정밀 측정)

  • Kim, Hyun-Ju;Yoon, Doo-Hyun;Kim, Hak-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.376-380
    • /
    • 2008
  • This paper presents the Projection Moire method using a line scan camera. The high resolution feature of a line scan camera makes it possible to scan an image quickly, thus enabling a much quicker 3D profile. This method uses a high resolution line scan camera making it possible to scan an image at high speed simultaneously measuring the 3D profile of a large FOV. When using a high resolution scan camera, a full FOV is scanned, thus requiring just one movement of a projection grating. As a result, the number of grating movements is reduced drastically. The end result is a faster and more accurate 3D measurement. Moving the grating too quickly causes vibration in the imaging system, which will normally be required to apply a stitching technique when using an area scan camera. However the technique is not required when using a line scan camera. Compared with the previous techniques, it has the advantages of simple hardware without moving mechanical parts - single exposure for obtaining three-dimensional information. A method using a high resolution line scan camera can be used in mass production to measure the bump height of wafers or the bump height of package substrates.

Development of Measurement System for Traction and Braking (견인제동 계측시스템 개발)

  • Kim, Seog-Won;Han, Young-Jae;Choe, Kang-Youn;Kim, Young-Guk;Kim, Jong-Young;Park, Tae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.270-276
    • /
    • 2004
  • In this paper, we introduce the software and hardware of the measuring system for on-line test and performances evaluation of traction and braking in KTX(Korea Train Express). The measuring system focuses on the verification of the performance and acquisition of test data. The hardware is connected many kinds of sensors, such as speed sensor, thermocouple. The software controls the hardware of the measuring system, performs the analysis and calculation of measurement data and acts as interface between users and the hardware. For this purpose, three programs, such as a measuring program, a back-up program and a analysis program, have developed.

Ultrasonic-detecting Characteristics by Partial Discharge using the Fiber Mach-Zehnder Interferometerin Insulating Oil (광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성)

  • 심승환;이광식;이상훈;김달우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.325-328
    • /
    • 2002
  • The partial-discharge(PD) is accompanied by physical and chemical phenomena, such as heat, light, noise, gas, chemical transformation, electric current, and electromagnetic radiation. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Now a fiber-optic sensor for detecting ultrasonics is suggested for the on line measurement system with high accuracy. In this paper, an optical fiber sensor utilizing the principal of Mach-Zehnder interferometer was proposed to detect the discharge signal.

  • PDF

Drift Compensation Algorithm of Acceleration Sensor for Galloping Measurement System (갤로핑 측정을 위한 가속도 센서 드리프트 보상 알고리즘)

  • 변기식;안영주;김환성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.914-920
    • /
    • 2003
  • In this paper, we deal with two drift compensation algorithms of acceleration sensor for measuring the galloping on power transmission line. Firstly, the block diagram of galloping measurement system is given and a galloping model is presented. Secondly, two compensation algorithms, a simple compensation and a period compensation, are proposed. A simple compensation algorithm uses the drifts of velocity and distance at fixed periods, so it is useful for constant drift case. Next, a period compensation algorithm can compensate a periodic drift. This algorithm uses the previous measured data and compensated data for constant period, where the period is obtained by FFT method. Lastly, the effectiveness of proposed algorithms is verified by comparing between two algorithms in simulation, and its characteristics and the drift error bound are shown, respectively.

Development of High-resolution 3-D PIV Algorithm by Cross-correlation (고해상도 3차원 상호상관 PIV 알고리듬 개발)

  • Kim, Mi-Young;Choi, Jang-Woon;Lee, Hyun;Lee, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.410-416
    • /
    • 2001
  • An algorithm of 3-D particle image velocimetry(3D-PIV) was developed for the measurement of 3-D velocity field of complex flows. The measurement system consists of two or three CCD camera and one RGB image grabber. In this study, stereo photogrammetty was applied for the 3-D matching of tracer particles. Epipolar line was used to decect the stereo pair. 3-D CFD data was used to estimate algorithm. 3-D position data of the first frame and the second frame was used to find velocity vector. Continuity equation was applied to extract error vector. The algorithm result involved error vecotor of about 0.13 %. In Pentium III 450MHz processor, the calculation time of cross-correlation for 1500 particles needed about 1 minute.

  • PDF

Three-dimensional Information and Refractive Index Measurement Using a Dual-wavelength Digital Holographic

  • Shin, Sang-Hoon;Yu, Young-Hun
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.173-177
    • /
    • 2009
  • Digital holographic microscopy allows optical path difference measurement. Optical path difference depends on the both refractive index and morphology of sample. We developed a dual-wavelength in-line digital holographic microscope that can measure simultaneously the refractive index and morphology of a sample, providing highly precise three-dimensional information. Here we propose theoretical and experimental methods for dual-wavelength in-line digital holographic microscopy. The measured data were reasonable, although there was data error. By improving the experimental method, we could measure the refractive index more precisely and obtain more accurate three-dimensional information on samples.

선형 CCD를 이용한 MTF방법에 의한 카메라 렌즈 초점거리의 출정 및 보정 시스템 개발

  • 박희재;이석원;김왕도
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.8
    • /
    • pp.71-80
    • /
    • 1998
  • A computer aided system has been developed for the focal length measurement/compensation in camera manufacture. Signal data proportional to light intensity is obtained and sampled very rapidly from the line CCD. Based on the measured signal, the MTF performance is calculated, where the MTF is the ratio of magnitude of the output image to the input image. In order to find the optimum MTF performance, an effcient algorithm has been implemented using the least squares technique. The developed system has been applied to a practical camera manufacturing process, and demonstrated high productivity with high precision.

  • PDF

The Development of Magnetic Field Measurement System of 3 Axis (3축 자계 측정 시스템의 개발)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.253-257
    • /
    • 2017
  • Nowadays, it is increasingly important to detect whether cables are live for the operator's safety if there is a sudden power failure. It is especially hard to detect the electrical field of an underground line because of shielding. This paper on detection of live-line states in cables studied the detection characteristics of the change in the magnetic field and axis as the frequency, voltage, and distance at the same load are changed using 3 axes. A search coil type was used as a magnetic field sensor with non-contact. We found that magnetic fields decrease proportionally to the square of the distance and the decrease of rated voltage with load effected to magnetic field. The magnetic field was detected by 3-axis sensors given correct proximity, but appeared as noise components beyond a distance of 2 cm.

Discussion of Problems During the Application of the On-line Particle Counter In Water Treatment Process (정수처리 공정에서 연속식 입자계수기의 적용성 검토에 관한 연구)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.214-220
    • /
    • 2005
  • Errors may occur due to analysis methods and water quality during the application of the on-line particle counter In water treatment process. Errors caused by analysis methods include particle destruction by shear force due to inflow speed and tube friction, as well as interruption by screening, bubbles and contaminants. Since errors happen frequently because of these factors, it is necessary to examine and evaluate such errors during the application of a particle counter. Errors can be large due to screening and bubbles. Measurement values are effective for water analysis after filtration process. However, because of screening, only measurement values for particles above $7{\mu}m$ are valid for water with a turbidity between 3-10NTU. As particle numbers around $10{\mu}m$ increase a lot after ozone treatment, sufficient pretreatment process is necessary. Physical conditions should keep stable for inflow to decrease errors caused by shear force.

A study on establishment of measurement and analysis frequency of maintenance monitoring in tunnel (터널 유지관리계측의 측정 및 분석주기 설정 연구)

  • Woo, Jong-Tae;Lee, Kang-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.2
    • /
    • pp.117-129
    • /
    • 2012
  • In this study, research was performed to establish the measurement and frequency of analysis for maintenance monitoring by investigation of tunnel maintenance monitoring system in the tunnel which was installed in the Seoul metro line 5, 7 and 8, using that the domestic and foreign application case, results of analyzed maintenance monitoring in the domestic tunnel and legal safety management standard of the facility. The results of the monitoring management about analysis frequency to the present are considered that the problem about measuring frequency does not occur. According to the analysis results of the maintenance monitoring which are located on the 5, 6th subway line, they are analyzed that the stress of concrete lining and reinforced bar are converged gradually after 45 months. Therefore Monitoring of measurement and analysis frequency is conduct more often within about 4 years after the measuring instrument installation. Four years later, slowing the frequency of measurement is considered reasonable.