• Title/Summary/Keyword: In-line measurement

Search Result 2,374, Processing Time 0.031 seconds

A Study on the Performance Improvement of a 3-D Shape Measuring System Using Adaptive Pattern Clustering of Line-Shaped Laser Light (선형레이저빔의 적응적 패턴 분할을 이용한 3차원 표면형상 측정 장치의 성능 향상에 관한 연구)

  • Park, Seung-Gyu;Baek, Seong-Hun;Kim, Dae-Gyu;Jang, Won-Seok;Lee, Il-Geun;Kim, Cheol-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.119-124
    • /
    • 2000
  • One of the main problems in 3D shape measuring systems that use the triangulation of line-shaped laser light is precise center line detection of line-shaped laser stripe. The intensity of a line-shaped laser light stripe on the CCD image varies following to the reflection angles, colors and shapes of objects. In this paper, a new center line detection algorithm to compensate the local intensity variation on a line-shaped laser light stripe is proposed. The 3-D surface shape measuring system using the proposed center line detection algorithm can measure 3-D surface shape with enhanced measurement resolution by using the dynamic shape reconstruction with adaptive pattern clustering of the line-shaped laser light. This proposed 3-D shape measuring system can be easily applied to practical situations of measuring 3-D surface by virtue of high speed measurement and compact hardware compositions.

  • PDF

Development of a Camera-based Position Measurement System for the RTGC with Environment Conditions (실외 주행환경을 고려한 카메라 기반의 RTGC 위치계측시스템 개발)

  • Kawai, Hideki;Kim, Young-Bok;Choi, Yong-Woon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.9
    • /
    • pp.892-896
    • /
    • 2011
  • This paper describes a camera-based position measurement system for automatic tracking control of a rubber Tired Gantry Crane (RTGC). An automatic tracking control of RTGC depends on the ability to measure its displacement and angle from a guide line that the RTGC has to follow. The measurement system proposed in this paper is composed of a camera and a PC that are mounted on the right upper between front and rear tires of the RTGC's side. The measurement accuracy of the system is affected by disturbances such as cracks and stains of the guide line, shadows, and halation from the light fluctuation. To overcome the disturbances, both side edges of the guide line are detected as two straight lines from an input image taken by the camera, and parameters of the straight lines are determined by using Hough transform. The displacement and angle of the RTGC from the guide line can be obtained from these parameters with the robustness against the disturbances. From the experiments with the disturbances, we found the accurate displacement and the angle from the guide line that have the standard deviations of 0.95 pixels and 0.22 degrees, respectively.

Visual Precise Measurement of Pile Rebound and Penetration Movement Using a High-Speed Line-Scan Camera

  • Lim, Mee-Seub;You, Bum-Jae;Oh, Sang-Rok;Han, Song-Soo;Lee, Sang-Hun
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.341-346
    • /
    • 2002
  • When a construction company builds a high structure. many piles should be driven into the ground by a hammer whose weight is 7,000 kg in order to make the ground under the structure safe and strong. So. it is essential to determine whether a pile is penetrated into the ground enough to support the weight of the structure since ground characteristics at different locations are different each other. This paper proposes a visual measurement system for pile rebound and penetration movement including vibration using a high-speed line-scan camera and a specially designed mark to recognize two-dimensional motion parameters of the mark using only a line-scan camera. A mark stacking white and black right-angled triangles is used for the measurement, and movement information for vertical distance, horizontal distance and rotational angle is determined simultaneously. Especially- by adopting a line-scan CCD camera whose line rate is 20 ㎑. the measurement performance of dynamic characteristics of the pile at impact instant is improved dramatically.

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

Development of a Measurement System Development for On-Line Testing of High Speed Railway (고속철도 시운전시험 계측시스템 개발에 관한 연구)

  • 김석원;김영국;한영재;박찬경;김진환;백광선
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.3
    • /
    • pp.158-166
    • /
    • 2002
  • In this paper, we introduce the software and hardware of the measurement system for on-line testing and evaluation of high speed railway. The test items focus on the verification of the performance and acquirement of the technical data of the high speed railway system. The software controls the hardware of the measurement system, perform the analysis and calculation of measurement data and acts as interface between users and the system hardware. For this purpose, three programs a measuring program, a monitoring program and post-processing program are developed. The detailed test scenario is in the process of development to closely follow the process of development and design of the system.

A Measurement and Analysis of Low Level Radiated-Noise Using Vertical Line Array (수직선배열을 이용한 저소음 함정음향 측정 및 분석기법)

  • Choi, Jae-Yong;Son, Kweon;Dho, Kyeong-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.55-64
    • /
    • 2003
  • Underwater acoustic noise measurement is an essential element for vulnerability assessment of modern naval platforms. But during the last few decades environmental conditions have drastically changed due to the gradually increasing sea ambient noise level and decreasing submarine radiated noise level. A real-time underwater acoustic measurement system with vertical line array is designed for the quiet submarine radiated noise assessment in challenging environment. This system has a constant directivity index in measurement frequency range and accurate tracking capability for the transmission loss compensation and navigation aids inside the submarine. This system has been validated at sea and used several times for the submarine noise measurement.

A Study on On-line 5 Degrees of Freedom Error Measurement using Laser Optical System (레이져 광학장치를 이용한 온라인 5 자유도 오차측정에 관한연구)

  • 김진상;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.375-378
    • /
    • 1995
  • Although laser interferometer measurement system has the advantage of range and accuracy, the traditional error measurement methods for geometric errors(two straightness and three angular errors) of a machine tool measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric error of a moving body, an on-line measurement system for simultaneous detection of the five error components of a moving axis is required. An on-line measurement system with 5 degrees of freedom was developed for geometric error detection. Performance verification of the system was performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a side of machine tool.

  • PDF

A STUDY ON USEFULNESS OF THE REFERENCE LINE IN DIAGNOSIS OF THE FACIAL ASYMMETRY (안모비대칭의 진단용 기준선의 유용성에 관한 연구)

  • Ryu, Sung-Ho;Chang, Hyun-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.266-273
    • /
    • 2005
  • Purpose: To assess the relationship between soft tissue reference line and hard tissue reference line using the standardized photographs and the posteroanterior cephalometric radiographs(P-A)in facial asymmetric patients and to compare the differences of angular measurement between normal group and asymmetry group. Methods: Normal group consisted of 44 persons with normal occlusion and normal facial morphology. Asymmetry group consisted of 90 patients with facial asymmetry. Standardized facial photographs and P-A were taken in all subjects. The horizontal reference lines were bipupillary line in photographs and latero-orbitale line in P-A respectively. The vertical reference line were the line from the midpoint of horizontal reference line perpendicularly. Angular measurement of otobasion canting, lip canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in photographs. And angular measurement of mastoid canting, mandibular canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in P-A. Results: 1. The variables of photographs and P-A were significantly related in the asymmetry group. 2. Significant differences between all variables except for PT2 and PA2 were shown in the asymmetry group and between PT1 and PA1, PT3 and PA3 in the normal group respectively. 3. Comparison measurement scores of angular difference between control group and experimental group concerning each variable showed significant difference except for PA1. Conclusions: Soft tissue components may not compensate for underlying skeletal imbalance in nose deviation and chin deviation. The horizontal reference lines in photographs were significant related with the P-A, but angular variables between the two studies show significant differences. Therefore, we do not recommend use photography in the assessment the facial asymmetry as complemented in the P-A.

The Study of Somatotype According to the Drop of Women in Their 20's (20대 여성의 드롭에 따른 체형 연구)

  • Park, Ju-Hee;Hong, Jung-Min;Yoon, Jin-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.7 no.5
    • /
    • pp.494-500
    • /
    • 2005
  • This study classifies somatotype from exact measurements according to the women somatotype with different drop value and isfunctional and has high body fitness. This study was preceded in the following process. Took 147 women in their 20's measurement directly and grasped the general body characteristic, and classified somatotype according to distribution of drop. Drop value is classified into Drop I, Drop II, and Drop III. Drop I is the difference value between bust line and waist line measurement. Drop II is the difference value between hip line and waist line measurement. Drop III is the difference value between hip line and bust line measurement. Suggested distribution of somatotype based on drop istribution. Classified somatotype into 4 types according to the mixture of combination of Drop I, II, and III. Comprehended the characteristics of somatotype based on basic statistical data. Type 1, M type, displays 40 % distribution that is most high distribution rate among four types and it is normal type which is similar to average value in size in the this study. Type 2, A type, displays 32.4% and it's a lower half of their body developed type with a flat busted and hippy. Type 3, X type, displays 19% and it's a healthy type with tall height, slender waist and curves of bust and hip lines. Type 4, H type, displays 8.6% and it's a biggest type in size which is busty, full hipped and nearly has no curves of body line.

Analysis of Channel Noise and Impedance Characteristics for High-Speed Power-Line Communication (고속 전력선 통신을 위한 전력선채널 잡음 및 임피던스 특성 분석)

  • 김정훈;김선효;김상태;이영철;신철재
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.37-40
    • /
    • 2001
  • Subject of this paper is analysis of channel noise and impedance characteristics for high speed power line communication to concerned noise of transmission line and impedance in the frequency range up to 30MHz. Parameters of transmission line was inducted from experimentally power line channel measurement. Moreover, Analysis of compared based on measurement of channel characters with simulation test for appear characters.

  • PDF