• Title/Summary/Keyword: In-line measurement

Search Result 2,374, Processing Time 0.048 seconds

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.1
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

Development of a Measurement System for Curved Ship Hull Plates with Multi-Slit Structured Light (다중 슬릿 구조화 광원을 이용한 곡판 측정장치 개발)

  • Lee, Hyunho;Lee, Don Jin;Huh, Man Joo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.292-299
    • /
    • 2013
  • The measurement in the manufacturing process of curved ship hull plates still depends on wooden templates as a standard instrument. The metrology-enabled automation in the shipbuilding process has been challenged instead of line measurement with wooden templates. The developed measurement system consists of a CCD camera, multiple structured laser sources and 3-DOF motion device. The system carries out measurement of curved profiles for large scale plates by an optical triangulation method. The results of experiment conducted in a manufacturing shop demonstrate the accurate and robust performance.

A Study on Curvature Radius Measurement Using Laser Interferometer (레이저 간섭계를 이용한 곡률반경 측정에 관한 연구)

  • Lee Ji Yong;Kim Min Ju;Lee Seung Soo;Jeon Eon Chan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.34-40
    • /
    • 2004
  • This paper presents studies on curvature radius measurement using the laser interferometer. It is a general practice to measure to $10^{-10}$m in length with the recent improvement and innovations in measurement technology and the processor used. The measurement methods can generally be categorized as these two: the contactual method and non-contactual method; and in this study, we will find ways to lower the cost for a CMM, or a coordinate measurement machine, and try to find an alternative. Furthermore, we will discuss some of the ways to improve the non-contactual measurement methods-optical interferometer method and the optical triangulation method. We will measure an object using a laser distance measuring device and Set the Point-contact result with the ball-bearing type and line-contact result with the bearing type, to decide on which probe type will be used.

Analysis of Characteristics of Residential Distribution Line for Design of Power Line Communication Systems (전력선 통신 시스템 설계를 위한 주택배선의 선로특성 분석)

  • Hong, Ducpyo;Choi, Jaeho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.99-104
    • /
    • 2005
  • This paper describes the measurement and analysis of the basic line constants in PLC(Power Line Communication) in the residential building. An apartment is considered as one of the conventional residences to get the line constants in this paper, Agilent 4263B LCR Meter is used to measure the detailed values each area and the specific results and averaged analysis data are shown in the tables. The measured results are a little bit different from the calculated values using conventional formula due to the line arrangement, neglected factors, complex permittivity, and etc. This paper describes many kinds of lines and wiring figures of domestic construction. It can be utilized with the analyzed line characteristics in frequency domain as a planning reference of PLC.

Emissive Electromagnetic Field Measurement and Analysis for High Speed PLC on Medium Voltage Power-Line Channel (고속 전력선 통신을 위한 중전압 선로의 방사전자파 측정 및 분석)

  • 김선효;김상태;이영철;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 2003
  • This paper shows the results of emissive electromagnetic field characteristics on medium voltage power line(22.9 kV). The measurements were taken when communications signals were coupled into the 22.9 kV main wire of medium voltage power-line in a frequency range of 9 kHz to 30 MHz. The results of the measurement are as follows-emissive electromagnetic Held characteristics from multi carrier signals were superior to a single carrier signal. And we confirmed the PLC transmission distance was 1.8 km when multi-carrier transmission power was 20 dBm. Electric field strength was under the 40 dBuV/m at 30 MHz when 10 m method was measured.

Relationship between Apparent Viscosity and Line-Spread Test Measurement of Thickened Fruit Juices Prepared with a Xanthan Gum-based Thickener

  • Kim, Sung-Gun;Yoo, Whachun;Yoo, Byoungseung
    • Preventive Nutrition and Food Science
    • /
    • v.19 no.3
    • /
    • pp.242-245
    • /
    • 2014
  • The flow behaviors of three thickened fruit juices (orange, apple, and grape juice) prepared with a commercial instant xanthan gum (XG)-based thickener that is marketed in Korea were investigated at different thickener concentrations (1.0%, 1.5%, 2.0%, 2.5%, 3.0%, and 3.5%) and setting times (5 and 30 min) using a rheometer and a line-spread measurement method. The flow distance values measured by the line-spread test (LST) were compared with the apparent viscosity (${\eta}_{a,50}$) values measured with a sophisticated computer-controlled rheometer. The ${\eta}_{a,50}$ values of the juices increased as thickener concentration increased, whereas their flow distances decreased. The ${\eta}_{a,50}$ values at the 30-min setting time were much higher than those at the 5-min setting time, indicating that the setting time before serving or consuming thickened juices can affect viscosity values. Plots comparing ${\eta}_{a,50}$ values to LST flow distances revealed strong exponential relationships between the two measures ($R^2$=0.989 and $R^2$=0.987 for the 5- and 30-min setting times, respectively). These results indicate that the LST can be a suitable instrument for evaluating the viscosity of thickened fruit juices prepared with different XG-based thickener concentrations and setting times for the dysphagia diet.

A study on the effect of the condition number in the magnetic field mapping of the Air-Core solenoid

  • Huang, Li;Lee, Sangjin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.2
    • /
    • pp.31-35
    • /
    • 2015
  • Mapping is a useful tool in the magnetic field analysis and design. In some specific research area, such as the nuclear magnetic resonance (NMR) or the magnetic resonance imaging (MRI), it is important to map the magnetic field in the interesting space with high accuracy. In this paper, an indirect mapping method in the center volume of an air-core solenoid is presented, based on the solution of the Laplace's equation for the field. Through the mathematical analysis on the mapping calculation, we know that the condition number of the matrix, generated by the measurement points, can greatly affect the error of mapping result. Two different arrangement methods of the measurement points in field mapping are described in this paper: helical cylindrical line (HCL) method and parallel cylindrical line (PCL) method. According to the condition number, the HCL method is recommended to measure the field components using one probe. As a simple example, we mapped the magnetic fields in a MRI main magnet system. Comparing the results in the different methods, it is feasible and convenient to apply the condition number to reduce the error in the field mapping calculation. Finally, some guidelines were presented for the magnetic field mapping in the center volume of the air-core solenoid.

Monitoring Inductance Change to Quantitatively Analyze Magnetic Wear Debris in Lubricating Oil (인덕턴스 측정에 의한 윤활유 내 자성입자 정량적 평가)

  • Koo, HeeJo;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.32 no.6
    • /
    • pp.189-194
    • /
    • 2016
  • Wear debris in lubricating oil can be indicative of potential damage to mechanical parts in rotating and reciprocating machinery. Therefore, on-line or in-line monitoring of lubricating components in machinery is of great importance. This work presents a device based on inductive measurement of lubricating oil to detect magnetic wear particles in a tested volume. The circuit in the device consists of Maxwell Bridge and LVDT to measure inductance differences between pure and contaminated oil. The device detects the passage of ferrous particles by monitoring inductance change in a coil. The sensing principle is initially demonstrated at the microscale using a solenoid. The device is then tested using iron particles ranging from $50{\mu}m$ to $100{\mu}m$, which are often found in severely worn mechanical components. The test results show that the device is capable of detecting and distinguishing ferrous particles in lubricating oil. The design concept demonstrated here can be extended to an in-line monitoring device for real-time monitoring of ferrous debris particles. A simulation using the CST code is performed to better understand the inductive response in the presence of magnetic bodies in the oil. The CST simulation further verifies the effectiveness of inductance measurement for monitoring magnetic particles within a tube.

Reliability of Scapular Downward Rotation Measurement in Subjects With Scapular Downward Rotation Syndrome

  • Choi, Woo-Jeong;Lee, Ji-Hyun;Jeong, Hyo-Jung;Yoon, Tae-Lim;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.21 no.3
    • /
    • pp.73-79
    • /
    • 2014
  • The purposes of the current study were to (1) estimate the inter-rater agreement for visual assessment of scapular downward rotation (SDR), (2) develop the scapular downward rotation index (SDRI) as a method to measure SDR objectively and quantitatively, and (3) analyze the intra- and inter-rater reliability of the SDRI. Twenty subjects with scapular downward rotation syndrome (SDRS) were recruited for this study. The visual assessment and the measurement for the SDRI were conducted by two examiners in two sessions each. The SDRI [$(a-b){\div}a{\times}100$] is calculated with the measurement of two linear distances: One is a perpendicular distance from the root of the scapular spine to the thoracic mid-line (a), and the other is a perpendicular distance from the inferior angle of the scapula to the thoracic mid-line (b). Cohen's kappa coefficient was calculated to estimate the inter-rater agreement for visual assessment. Intra-class correlation coefficients (ICCs) with a 95% confidence interval (CI), the standard error of measurement, and minimal detectable differences were calculated to assess intra- and inter-rater reliability of SDR measurement using the SDRI. The results indicated that the kappa coefficient of inter-rater agreement for visual assessment was fair (${\kappa}=.21$). The intra-rater reliability of SDR measurement using the SDRI was excellent for examiner 1 (ICC=.92, 95% CI=.78~.97) and good for examiner 2 (ICC=.82, 95% CI=.55~.93). The inter-rater reliability was moderate (ICC=.73, 95% CI=.32~.89). These findings showed that SDR measurement using the SDRI for subjects with SDRS may be considered reliable and better than the visual assessment.

In-Process Relative Robot WorkCell Calibration

  • Wang, Jianjun;Sun, Yunquan;Gan, zhongxue
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.269-272
    • /
    • 2003
  • Industry is now seeing a dramatic increase in robot simulation and off-line programming. In order to use off-line programming effectively, the simulated workcell has to be identical to the real workcell. This requires an efficient and accurate method for the workcell calibration. Currently used techniques in the industry, however, are typically time-consuming, expensive and therefore not suitable for in-process application. This is because most of these techniques are based on the so-called “absolute calibration” method. In contrast to absolute method, relative calibration only measures the difference of an interested object relative to a standard reference. Owing to the small measurement range requirement, relative calibration method is very cheap and can achieve very high accuracy. In this paper the relative method is applied to calibrate an entire grinding workcell. Linear gauge is the only measurement device used. This workcell calibration includes tool center point (TCP) calibration and work object frame calibration. Due to the efficiency of the calibration algorithm and the simplicity of the calibration setup, the described calibration procedure can be done in process.

  • PDF