• Title/Summary/Keyword: In-line measurement

Search Result 2,374, Processing Time 0.033 seconds

Diagnosis of power cable system based on the HFPD detection at on-site (HFPD 검출법을 이용한 지중 케이블 실선로 진단)

  • Lee, J.S.;Kim, C.S.;Lee, D.G.;Kong, C.H.;Seok, K.H.;Lee, K.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.97-100
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnosis of cable system in the world although Korea just begin. The efficiency of measurement has been reported and proved by many researchers who are engaged in the diagnosis of high power apparatus. LG Cable has investigated the technology of diagnosis for cable system by means of PD measurement for 10 years. In this paper, PD measurement with portable device was performed to evaluate the quality of the 154kV transmission line and the 22.9kV XLPE cable line. Test results are shown that the HFPD detection technology is very attractive for the diagnosis of power cable system by high detection sensitivity at on-site.

  • PDF

Development of an Uplift Measurement System for Overhead Contact Wire using High Speed Camera (고속카메라를 이용한 전차선 압상량 검측 시스템 개발)

  • Park, Young;Cho, Yong-Hyeon;Lee, Ki-Won;Kim, Hyung-Jun;Kim, In-Chol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.864-869
    • /
    • 2009
  • The measurement of contact wire uplift in electric railways is one of the most important test parameters to accepting the maximum permitted speed of new electric vehicles and pantographs. The contact wire uplift can be measured over short periods when the pantograph passes monitoring stations. In this paper, a high-speed image measurement system and its image processing method are being developed to evaluate dynamic uplift of overhead contact wires caused by pantograph contact forces of Korea Tilting Train eXpress (TTX) and Korea Train eXpress (KTX). The image measurement system was implemented utilizing a high-speed CMOS (Complementary Metal Oxide Semiconductor) camera and gigabit ethernet LAN. Unlike previous systems, the uplift measurement system using high speed camera is installed on the side of the rail, making maintenance convenient. On-field verification of the uplift measurement system for overhead contact wire using high speed camera was conducted by measuring uplift of the TTX followed by operation speeds at the Honam conventional line and high-speed railway line. The proposed high-speed image measurement system to evaluate dynamic uplift of overhead contact wires shows promising on-field applications for high speed trains such as KTX and TTX.

Measurement during Construction of Nakdong Bridge by Incremental Launching Method (낙동강교 ILM 가설에 따른 시공 중 계측)

  • Kim, Hyung-Tae;Cho, Nam-So;Jung, Ji-Man;Yang, Sung-Man
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.575-580
    • /
    • 2007
  • As the volume of traffic in southern part of the republic of Korea grew, expansion of transportation was required. In that purpose, the railway between Samnangjin and Gwangyang is being extended to a double-track line. This construction includes Nakdong bridge located across Nakdong river. This truss bridge is constructed in incremental launching method (ILM) and composed of two sections, straight line and curved one. Bridge construction in the method goes with the shift of roller supports which results in the change of structural system. To accomplish safe construction, the measurement during the whole launching stages. The locations of member in severe condition and the corresponding response values were estimated through the preliminary construction stage analysis. Based on the analysis, the measurement during construction was planned. Several sensors and measurement devices were installed at appropriate locations. During the whole launching stages, the measurement was performed and the corresponding data were monitored and stored in real time. The comparison of the responses from the analysis and the measurement showed no indication of yielding of the structural members. Consequently, the construction of Nakdong bridge was concluded to be relevant.

  • PDF

Temperature Measurement Method of Main Transformer for High Speed Railway (고속철도차량 주변압기의 온도측정방법)

  • Han, Young-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.448-451
    • /
    • 2003
  • For this research, we developed the hardware and software of the measurement system for on-line test and evaluation. The software controls the hardware of the measurement data and acts as interface between users and the system hardware. In this paper, we is studied for temperature measurement of main transformer. In order to this test is developed measurement system. Using this system, we obtained important result for main transformer temperature.

  • PDF

ON-LINE DYNAMIC SENSING OF SHIP'S ATTITUDE BY USE OF A SERVO-TYPE ACCELEROMETER AND INCLINOMETERS

  • Tanaka, Shogo;Nishifuji, Seiji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.162-165
    • /
    • 1995
  • For an accurate on-line measurement of the ship's attitude the paper develops an intelligent sensing system which uses one servo-type accelerometer and two servo-type inclinometers appropriately located on the ship. By considering the dynamics of the servo-controlled rigid pendulums of the inclinometers, linear equations for the rolling and pitching of the ship are derived separately from each other. Moreover, one accelerometer is used for extracting the heaving signal. Through the introduction of linear dynamic models and the linear observation equations for the heaving, rolling and pitching, the on-line measurement of the three signals can be reduced to the state estimation of the linear dynamic systems. A bank of Kalman filters is adaptively used to achieve the on-line accurate state estimation and to overcome changes in parameters in the linear dynamic models.

  • PDF

A Study on Effective Management for Measurement System (측정시스템의 효율적 운영에 관한 실증적 연구 - 중소제조기업(中小製造企業)을 중심(中心)으로 -)

  • Yoo, Hyun-Jong;Jun, Hyun-Jung;Yoo, Jae-Kwon
    • Journal of Industrial Convergence
    • /
    • v.1 no.2
    • /
    • pp.95-105
    • /
    • 2003
  • "All things possibly could be measured.", measurement is a essential part in all kinds of industry, especially in manufacturing. Korean Industrial Standard has been established and announced in September, 1961. Measurement has been emphasized. But until now, measurement hasn't been located to the core of manufacturing in domestic. So, this study suggests improvement guide line for the multilateral problems of measurement system based on the investigation of 146 small and medium-sized enterprises in April, 2002.

  • PDF

New Techniques for Impedance Characteristics Measurement of Islanded Microgrid based on Stability Analysis

  • Hou, Lixiang;Zhuo, Fang;Shi, Hongtao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1163-1175
    • /
    • 2016
  • In recent years, microgrids have been the focus of considerable attention in distributed energy distribution. Microgrids contain a large number of power electronic devices that can potentially cause negative impedance instability. Harmonic impedance is an important tool to analyze stability and power quality of microgrids. Harmonic impedance can also be used in harmonic source localization. Precise measurement of microgrid impedance and analysis of system stability with impedances are essential to increase stability. In this study, we introduce a new square wave current injection method for impedance measurement and stability analysis. First, three stability criteria based on impedance parameters are presented. Then, we present a new impedance measurement method for microgrids based on square wave current injection. By injecting an unbalanced line-to-line current between two lines of the AC system, the method determines all impedance information in the traditional synchronous reference frame d-q model. Finally, the microgrid impedances of each part and the overall microgrid are calculated to verify the measurement results. In the experiments, a simulation model of a three-phase AC microgrid is developed using PSCAD, and the AC system harmonic impedance measuring device is developed.

Multi-sensor Visual inspection for Seamless Steel Pipe´s Straightness

  • Tomoo, Aoyama;Zhang, Y.G.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.88.3-88
    • /
    • 2001
  • In this paper, an on-line multi-sensor visual inspection technique for seamless steel pipe´s straightness is developed. The basic principle of the visual measuring method is detailed. The modeling of visual sensor, measurement system and data processing are presented. In order to test the accuracy of the multi-sensor visual inspection, an experiment inspecting the straightness of a 1500mm long seamless steel pipe is made. The experiment results show that the visual inspection technique can achieve on-line measurement and offers high precision and stability.

  • PDF

Analysis of power line phasor measurement error (Power line phasor 측정 오차 해석 연구)

  • Kim, Byoung-Il;Chang, Tae-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.367-368
    • /
    • 2006
  • This paper presents an analytic derivation of phase measurement error. The analysis derives the measurement error caused by the finite-bit quantization of both input signals and twiddle factors used in the recursive implementation of the phasor measurement algorithm. The derivation is based on the statistical exploration of the error dynamic equations. The effect of frequency deviation and the number of DFT points are also included in the study. The analysis results are verified with the data obtained from the computer simulation by widely varying the values of error causing factors.

  • PDF

Measurement of Gas Concentration and flow Rate Using Hot Wire (열선을 이용한 혼합기체의 농도와 유량의 측정)

  • Kim, Young-Han;Park, Jong-Jueng
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.