• Title/Summary/Keyword: In-line filtration

Search Result 64, Processing Time 0.023 seconds

Prediction of Off-line Type Pulse Air Jet Bag Filter Reflection Distance (간헐탈진형 충격기류식 여과집진장치의 여과포 반사거리 예측)

  • Jeong-Sam Son;Yong-Hyun Chung;Jeong-Min Suh
    • Journal of Environmental Science International
    • /
    • v.32 no.11
    • /
    • pp.801-809
    • /
    • 2023
  • The purpose of this study is to predict the reflection distance following to the pulsing pressure, total air supplying, filter bag size using numercial analysis techniques and use it as an efficient operation condition and economic data for off-line type pulse air jet bag filter. In this research, filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the main experiments using coke dust. Ansys fluent V19.0 apply to CFD simulation, and analysis pulsing characteristics about pulsing pressure, filtration velocity and nozzle diameter. The maximum reflecting distance of off-line type pulse air jet bag filter is 1,000 mm regardless of total air supplying at over the 42 L/m2 conditions, that indicates off-line type can extend filter bag length 1,000 mm than on-line type. In order to effective primary and secondary pulsing of off-line type pulse air jet bag filter, over the 5 bar of pulsing pressure and over the 42 L/m2 of total air supplying are needed.

Filtration Characteristics of Paticulate Matter at Bag Filters Coated with PTFE Membrane During Off-Line Pulsing (PTFE membrane이 코팅된 여과백의 off-line 탈진시 미세먼지 집진 특성)

  • Kim, Joung-Hun;Moon, Il-Shik;Hwang, Min-Young;Kim, Ryang-Gyoon;Ko, Daekwun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.7
    • /
    • pp.391-402
    • /
    • 2017
  • Particulate matter becomes an important issue in the environmental society recently so that it is necessary to evaluate that the commercial application of baghouse systems for effective control of fine particulates is viable. A laboratory-scale baghouse experimental apparatus with filter bags made of PTFE felt or PTFE felt coated with PTFE membrane is used to investigate the filtration performances of fine particulates. Experiments by changing filtration velocity, inlet dust concentration, and average dust particle size show that the dust collection efficiency becomes higher at lower filtration velocity, higher inlet dust concentration and larger average dust particle size. The total pressure drop through the filter media and dust layer becomes higher at higher filtration velocity and higher inlet dust concentration. The dust collection efficiency is higher and the pressure drop is lower at a baghouse with filter bags coated with PTFE membrane than that without membrane coating. From the result that the dust collection efficiency of $PM_{2.5}$ in a reasonable filtration velocity range during off-line pulsing at a baghouse with PTFE felt bag filters coated with PTFE membrane is as high as 99.99%, it is confirmed that the use of baghouse is an effective measure to control the fine particulates.

A Study on Backwashing of Granular Fiters Used in Water Treatment (정수처리를 위한 여과지의 역세척에 관한 연구)

  • Lee, Jung Taek;Ahn, Jong Ho;Choi, Keun Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

Performance of the Exhaust Filtration System of Hot Cell at PIEF (조사후시험시설에서의 핫셀 배기포집시스템의 성능평가)

  • Hwang, Yong-Hwa
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.

Analysis of Fouling Propensity due to Scale Formation in the Treatment of Shale Gas Produced Water Using Direct Contact Membrane Distillation (DCMD) (직접 접촉식막증발을 이용한 셰일가스 발생수의 처리에서 스케일 형성에 의한 막오염 경향 분석)

  • Shin, Yonghyun;Ko, Younghoon;Choi, Yongjun;Lee, Sangho;Sohn, Jinsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.511-519
    • /
    • 2016
  • Shale gas has become increasingly important as a viable alternative to conventional gas resources. However, one of the critical issues in the development of shale gas is the generation of produced water, which contains high concentration of ionic compounds (> TDS of 100,000 mg/L). Accordingly, membrane distillation (MD) was considered to treat such produced water. Experiments were carried out using a laboratory-scale direct contact MD (DCMD). Synthetic produced water was prepared to examine its fouling propensity in MD process. Antiscalants and in-line filtration were applied to control fouling by scale formation. Fouling rates (-dJ/dt) were calculated for in-depth analysis of fouling behaviors. Results showed that severe fouling occurred during the treatment of high range produced water (TDS of 308 g/L). Application of antiscalant was not effective to retard scale formation. On the other hand, in-line filtration increased the induction time and reduced fouling.

A Method for k Nearest Neighbor Query of Line Segment in Obstructed Spaces

  • Zhang, Liping;Li, Song;Guo, Yingying;Hao, Xiaohong
    • Journal of Information Processing Systems
    • /
    • v.16 no.2
    • /
    • pp.406-420
    • /
    • 2020
  • In order to make up the deficiencies of the existing research results which cannot effectively deal with the nearest neighbor query based on the line segments in obstacle space, the k nearest neighbor query method of line segment in obstacle space is proposed and the STA_OLkNN algorithm under the circumstance of static obstacle data set is put forward. The query process is divided into two stages, including the filtering process and refining process. In the filtration process, according to the properties of the line segment Voronoi diagram, the corresponding pruning rules are proposed and the filtering algorithm is presented. In the refining process, according to the relationship of the position between the line segments, the corresponding distance expression method is put forward and the final result is obtained by comparing the distance. Theoretical research and experimental results show that the proposed algorithm can effectively deal with the problem of k nearest neighbor query of the line segment in the obstacle environment.

Treatment of Phosphorus and Suspended Solid in Reject Water of Sewage Using an Integrated Slow Mixing/Sedimentation and Net Fit Fiber Filtration System (일체형 완속교반/침전 그물망 압착식 섬유여과장치를 이용한 하수처리장 반류수 내 고농도 인 및 부유물질 처리)

  • Kim, Jeongsook;Kim, Min-Ho;Kim, Mi-Ran;Jang, Jeong-Gook
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.816-821
    • /
    • 2017
  • An integrated slow mixing/sedimentation and net fit fiber filtration system has been developed to reduce the high concentrations of suspended solid (SS) and total phosphorus (T-P) in the reject water from sewage/wastewater. A filtration device used in this experiment consists of coagulation, in-line mixing, air injection, slow mixing/sedimentation, and filtration processes. The performance test using this device was carried out with six operational modes for reject water from sewage treatment plant. Experimental conditions used were 16.7, 33.3, 41.7 and 50.0 ton/day of flow rate and 2~4 of Al/P molar ratio. By injection of coagulant in each operational mode, the high removal efficiencies of SS and T-P were obtained, but continuous operation time was decreased to 7.8~11.4 min in most modes. However, when the Mode 5 of the developed filtration device was applied, the continuous operation time was maintained up to 88.2 min. Also, it was found that the continuous operation time in the Mode 5 using the developed system was increased from 8 to 11.3 times longer than those in other modes. Backwashing flow rate was also very low at 5.4% of total filtered water. Therefore, it can be concluded that the Mode 5 of the developed filtration system was the most efficient treatment method for the removal of high concentrations of SS and T-P.

A Study on the Design of Artificial Stream for Riverbed Filtration in Multi-purpose Filtration Pond (다목적 여과저류지에서의 하상여과용 인공하천 설계연구)

  • Sohn, Dong-Hoon;Park, Jae-Young;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.536-543
    • /
    • 2011
  • In order to find the best design of artificial stream for the riverbed filtration in multi-purpose filtration pond, a mathematical model was developed employing the energy line and the Manning's formula and was analyzed by the Euler's technique. Various design factors were investigated through scenario analyses of the artificial stream using the model. Results showed that the appropriate slope of the stream bottom was 2/10,000 and the appropriate infiltration rate at the streambed was $2.5m^3/m^2-day$ for the pond with the area of 100 ha, and that the Manning's roughness coefficient in this case was expected to be about 0.026 and the maximum water-depth was less than 1m. It was also shown that the longer the artificial stream the more advantageous it became for the riverbed filtration. Furthermore, results showed that it was not an efficient way to prevent clogging of the streambed by increasing the flow velocity of the stream and that the performance was higher near a weir with a large head drop.

Lipids Supply for Hybridoma Culture (하이브리도마 배양을 위한 lipids의 공급)

  • 박상재;최차용
    • KSBB Journal
    • /
    • v.8 no.5
    • /
    • pp.483-487
    • /
    • 1993
  • BSA/acids component in serum free medium (SFM) developed for the culture of hybridoma cell line, KA112, was replaced by acids/Pluronic F-68 emulsion. Protein content of SFM was minimized, and increased maximum cell density was obtained in serum-free lipids supplemented medium (SFLSM). Cell growth promotion effect of the emulsion was not affected by filtration with 0.2$\mu$m filter.

  • PDF

A Study on Airborne Dust and Asbestos Concentrations in Subway Stations in Seoul Area (서울시 지하철 구내의 공기중 분진 농도에 관한 연구)

  • 백남원;박두용;장익선;신용철;이정인
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.2
    • /
    • pp.1-12
    • /
    • 1988
  • Airborne dust and asbestos fiber concentrations were determined in subway stations located in Seoul area. Two stations, such as Eulchiro 4-Ka Station of Line #2, constructed during a period of 1980-1984 and Hyehwa Station of Line #4, opened in 1985, were selected. The results of the study are as follows. 1. Daily time-weighted average (TWA) concentrations of airborne dusts from 07:00 to 20:00 hours in Line #2 and Line #4 were 0.43$\pm$0.08 mg/m$^3$ and 0.37$\pm$0.12 mg/m$^3$, respectively. Thus, the dust levels in Line #2 were significantly higher than the levels in Line #4 (p < 0.05). 2. Dust levels in the morning (07:00-11:00 hours), noon (11:00-16:00 hours) and in the evening (16:00-20:00 hours) in Line #2 were 0.47$\pm$0.17 mg/m$^3$, 0.37$\pm$0.08 mg/m$^3$, and 0.46$\pm$0.07 mg/m$^3$ respectively. Thus, dust levels in the morning and evening (i.e., during rush hours) were significantly higher than levels in the noon (p < 0.02). However, there was no such difference in dust levels by time in Line #4. 3. Airborne total dust concentrations were well below the occupational health standard of 10 mg/m$^3$, however, the levels were exceeding the ambient air standard recommended by the Korean Environment Administration. 4. All of airborne asbestos fiber concentrations were equal to or below 0.005 fibers/cc. The levels are within both occupational health standards and U.S. EPA criteria. 5. A consideration should be given to the improvements of cleaning methods (such as use of vacuum cleaning instead of brushing) and the existing ventilation (such as more air change and filtration of supply air) for a reduction of dust levels. 6. It is recommended that routine monitoring of airborne dusts and asbestos fibers be conducted because more dusts and asbestos fibers can be produced in the air due to the deterioration of facilities by age and water damage in future.

  • PDF