• 제목/요약/키워드: In situ Air Sparging(IAS)

검색결과 7건 처리시간 0.021초

고온 공기분사공정에 의한 유류오염대수층의 TPH 제거 (TPH Removal of Oil-Contaminated Soil by Hot Air Sparging Process)

  • 이준호;박갑성
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.665-675
    • /
    • 2007
  • In-situ Air Sparging (IAS, AS) is a remediation technique in which organic contaminants are volatilized from saturated zone to unsaturated layer. This study focuses on the removal and interaction of Volatile Organic Compounds (VOCs) and $CO_2$, and Total Petroleum Hydrocarbon (TPH) in saturated and unsaturated, and air space zone on the unsaturated soil surface. Soil sparging temperature of hot air has risen to $34.9{\pm}2.7^{\circ}C$ from $23.0{\pm}1.9^{\circ}C$ for 36 days. At the diffusing point, fluid TPH concentrations were reduced to 78.7% of the initial concentration in saturated zone when hot air was sparged. The TPH concentrations were decreased to 66.1% for room temperature air sparging. The amount of VOCs for hot air sparging system, in air space, was approximately 26% larger than constant air sparging system. The amount of $CO_2$ was 4,555 mg (in unsaturated zone) and 4,419 mg (in air space) when hot air was sparged was 3,015 mg (in unsaturated zone) and 3,634 mg (in air space) for room air temperature in the $CO_2$ amount. The removals of VOCs and biodegradable $CO_2$ through the hot air sparging system (modified SVE) were more effective than the room temperature air sparging. The regression equation were $Y=976.4e^{-0.015{\cdot}X}$, $R^2=0.98$ (hot air sparging) and $Y=1055e^{-0.028{\cdot}X}$, $R^2=0.90$ (room temperaure air sparging). Estimated remediation time was approximately 500 days, if final saturated soil TPH concentration was set to 1.2 mg/L application of tail effect.

현장공기분사공정법(IAS)을 이용한 공기 영향반경과 흐름 양상 연구

  • 이준호;박갑성
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.213-217
    • /
    • 2004
  • Laboratory scale study for an area of influence and flowing aspect of groundwater saturated zone was conducted for three sediment grains. On the AMG(Average Modal diameter Grains) 0.34, 1.38, 3.89mm diameter samples, the affected area of the aquifer were 15.2, 37.0, 30.0%/m2 each. Air flow for AMG 0.34mm diameter grain size provides indication of pattern of channelized air flow in saturated zone and expansion state in above saturated zone. For AMG of 1.38, 3.89mm diameter grains, air flow are pervasive air flow, forming a symmetrical cone of influence around the injection point. And also AMG 1.38, 3.89mm diameter samples show onset of collapse and approach to steady state in above saturated zone, respectively. In this study, optimal sites for in situ air sparging, may be grain diameters between about AMC 1.5~2.5mm diameter.

  • PDF

유류오염대수층 공기분사공정상의 미생물 제한효소다형성법 적용 평가 (Analysis of Microbial Community in the TPH-Contaminated Groundwater for Air Sparging using Terminal-Restriction Fragment Length Polymorphism)

  • 이준호;이상훈;조재창;박갑성
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.590-598
    • /
    • 2006
  • In-situ Air sparging (IAS) is a groundwater remediation technique, in which organic contaminants volatilize into air form the saturated to vadose zone. This study was carried out to evaluate the effect of sludge and soil microbial community structure on air sparging of Total Petroleum Hydrocarbons (TPH) contaminated groundwater soils. In the laboratory, diesel (10,000 mg TPH/kg) contaminated saturated soil. The Air was injected in intermittent (Q=1500 mL/min, 10 minute injection and 10 minute idle) modes. For Terminal-Restriction Fragment Length Polymorphism (T-RFLP) analysis of eubacterial communities in sludge of wastewater treatment plants and soil of experiment site, the 16S rDNA was amplified by Polymerase Chain Reaction (PCR) from the sludge and the soil. The obtained 16S rDNA fragments were digested with Msp I and separated by electrophoresis gel. We found various sequence types for experiment with sludge soil samples that were closely related to Agrococcus, Flavobacterium, Thermoanaerobacter, Flexibacter and Shewanella, etc, in the clone library. The results of the present study suggests that T-RFLP method may be applied as a useful tool for the monitoring in the TPH contaminated soil the fate of microorganisms in natural microbial community.

유류오염대수층에서 고온 공기분사공정법을 통한 TPH, VOCs, $CO_2$ 변화에 관한 특성인자 연구

  • 이준호;박갑성
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2005년도 총회 및 춘계학술발표회
    • /
    • pp.232-236
    • /
    • 2005
  • In-situ Air Sparging (IAS, AS) is a groundwater remediation technique, in which organic contaminants are volatilized into air as it rises from saturated to vadose soil zone. The purpose of this study was to investigate the effect of environmental conditions on the degradation of VOCs (Volatile Organic Compounds) and $CO_2$ in the unsaturated zone and TPH (Total Petroleum Hydrocarbons) in saturated zone of sandy loam. In the laboratory, diesel (10,000 mg TPH/kg)-contaminated saturated soil. After heating the soil for 36 days, the equilibrium temperature of soil reached to $34.9{\pm}2.7^{\circ}C$ and TPH concentration was reduced to 78.9% of the initial value, Volatilization loss of VOCs in TPH was about 2%, The reduction gradient of $CO_2$ concentration was 0.018/day in air space and 0.0007/day in unsaturated zone.

  • PDF

공기분사공정에 의한 유류오염대수층의 TPH, $CO_2$, VOCs 변화 특성 (TPH, $CO_2$ and VOCs Variation Characteristics of Diesel Contaminated Aquifer by In-situ Air Sparging)

  • 이준호;박갑성
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권6호
    • /
    • pp.18-27
    • /
    • 2006
  • 공기분사공정법은 포화대수층에 존재하는 유기화합오염물질들을 대기로부터 주입된 공기에 의해 불포화층으로 휘발시켜 제거하는 기술을 말한다. 이 연구의 목적은 TPH 10,000 mg/kg(액상 TPH 1,001 mg/L)으로 오염시킨 사질 포화대수층에 공기를 주입 하였을 때 불포화 토양층, 대기층에서 발생되는 이산화탄소, 휘발성유기화합물의 농도와 포화대수층(TPH) 농도 변화에 관한 특성 연구이다. 36일 동안 공기를 주입한 결과, 실험 반응조의 평형온도는 $24.9{\pm}1.5^{\circ}C$이었다. 포화대수층(공기 확산기 근처 C10 지점)에 녹아있는 TPH 농도는 초기주입 농도의 66.0%가 제거되었다. 대기중(C70 지점)에서 측정된 $CO_2$ 질량은 3,800 mg이였고 불포화 토양층(C50 지점)에서 측정된 $CO_2$의 질량은 3,200 mg이였다. 대기중(C70 지점) 및 불포화 토양층(C50 지점)에서 생성된 VOCs 속도상수는 각각 0.164/day, 0.187/day이였다.

증기추출법과 결합된 공기주입법을 이용한 비수용성액체 해양퇴적물의 TPHs, TCE, PCE 및 BTEX 정화 (Degradation of TPHs, TCE, PCE, and BTEX Compounds for NAPLs Contaminated Marine Sediments Using In-Situ Air Sparging Combined with Vapor Extraction)

  • 이준호;한선향;박갑성
    • 자원환경지질
    • /
    • 제46권5호
    • /
    • pp.425-444
    • /
    • 2013
  • 이 연구는 공기주입법(in-situ air sparging; IAS)이 결합된 증기추출법(vapor extraction; VE)을 이용한 실내 실험 연구로 비수용성액체 유기물(non-aqueous phase liquids; NAPLs)의 총유류계탄화수소(total petroleum hydrocarbons; TPHs), 트리클로에틸렌(trichloroethylene; TCE), 퍼클로로에틸렌(perchloroethylene; PCE), 벤젠(benzene), 톨루엔(toluene), 에틸벤젠(ethylbenzene) 및 크실렌(xylenes)을 제거하기 위한 목적으로 국내 만돌, 하전, 상암, 부산만내 해양 퇴적물들을 대상으로 실험 하였다. 만돌 퇴적물은 사질(sand; S) 특성(평균입도 1.789 ${\Phi}$), 하전은 모래실트(sandy Silt; sZ) 특성(평균입도 5.503 ${\Phi}$) 및 상암은 실트(Silt; Z) 특성(평균입도 5.835 ${\Phi}$)을 나타내었다. 그리고 부산지역 퇴적물은 점토(Clay; C) 특성(평균입도 8.528 ${\Phi}$)을 나타내었다. 48시간 동안 공기를 주입하지 않은 B1 (0 L/min) 컬럼에서 남아있는 TPHs는 만돌, 하전, 상암지역 및 부산지역 샘플퇴적물에서 각각 약 2,459, 6,712, 4,348, 14,279 ppm으로 분석 되었다. 그리고 만돌, 하전, 상암지역 및 부산지역 샘플퇴적물의 B2 (3 L/min)-B5 (5 L/min) 컬럼에서 TCE는 99.5-100.0% 제거되었으며, PCE는 93.2-100.0%까지 제거된 결과를 보였다. 입자크기에 따른 각 성분의 제거량과의 상관관계는 TCE, PCE, toluene, etylbenzene, xylene, BTEX에서 모두 0.90-0.99의 밀접한 상관계수를 보였다. 그러나 TPHs에서는 0.76, Benzene에서는 0.71의 낮은 상관계수를 보였다.

대수층 토양입자크기에 따른 공기분사 흐름 양상 (Effect of Sediment Size On Air Injection and Flowing Aspect of Groundwater Saturated Zone)

  • 이준호;박갑성
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제8권3호
    • /
    • pp.13-22
    • /
    • 2003
  • 현장공기분사공정의 복원효율에 있어서 중요한 인자로 작용 할 수 있는 것은 공기가 지하 포화대수층을 통과하면서 생기는 공기분사에 따른 흐름 양상과 토양입자크기에 따른 공기의 영향반경이다. 토양입자크기별 AMG 0.34, 1.38, 3.89 mm diameter 3가지 입자크기로 실험한 결과 AMG 0.34 mm diameter의 포화 대수층에서는 공기가 처음 결정된 방향으로만 흐르는 채널링 현상(channelized air flow)과 포화 대수층 가장 윗면에서는 확장모양(expansion state)을 가졌으며, 공기영향반경은 단위 면적당 15.2%/$\textrm{m}^2$이었다. AMG 1.38, 3.89 mm diameter의 포화 대수층에서는 공기가 퍼지는 현상(pervasive air flow)과 포화 대수층 가장 윗면에서는 각각 붕괴의 조짐(onset of collapse), 안정한 상태로 퍼짐모양(approach to steady state)을 가졌으며, 단위면적당 각각 37.0%/$\textrm{m}^2$, 30.0%/$\textrm{m}^2$영향반경이 계산되었다. 이 실험을 통해서 현장공기분사공정에 있어서 토양입자 크기에 따른 최대 영향반경효율을 얻을 수 있는 토양입자의 크기는 AMG 1.5-2.5 mm diameter로 사료된다.