• Title/Summary/Keyword: In - Plane Loads

Search Result 422, Processing Time 0.022 seconds

Studies on Strength of Netting (2) The Knot Strength of Knotted Notting with Meshes Opened (그물감의 강도에 관한 연구(2) 주름을 준 매듭 그물감의 매듭의 강도)

  • KIM Dai An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.1
    • /
    • pp.13-18
    • /
    • 1976
  • 1) The variation of the reef knot strength $T_r$ and the trawler knot strength $T_\varrho$ with the angle $\varphi$ between the adjacent bars are given by $$T_r=T_{ro}-k_{r\varphi}$$ and $$T_\varrho=T_{{\varrho}o}+k_{\varrho\varphi}$$ where $T_{ro}$ and $T_{{\varrho}o}$ are values of $T_r$ and $T_\varrho$ at $\varphi=0^{\circ}$ respectively, and $k_r$ and $k_\varrho$ constants decided by the fibre materials of netting twines ($\varphi\;is\;0^{\circ}$ when the knot is pulled lengthwise). 2) The variation of the reef knot strength $T_r'$ and the trawler knot strength $T_\varrho'$ with the angle $\varphi'$ between any one bar and the plane made by the other three bars may be expressed by $$T_r'=T_{ro}{'}\varrho^{-c\varphi'}$$ and $$T_\varrho'=T_{{\varrho}o}{'}\varrho^{-c\varphi'}$$ where $T_{ro}{'}$ and $T_{\varrho}o{'}$ are values of $T_r{'}$ and $T_\varrho{'}$ at $\varphi'=0^{\circ}\;{(\varphi=45^{\circ})}$ respectively, and o is the coefficient of attenuation. 3) Knot strength of knotted netting may be expressed by the expression derived in the preyious paper, disregarding its shape and the direction of tensile loads acting on it.

  • PDF

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF