• 제목/요약/키워드: Impurity gas

검색결과 134건 처리시간 0.022초

Effects of the Impurity Gases on the Characteristics of ac PDP

  • Shin, Joong-Hong;Park, Chung-Hoo
    • 한국전기전자재료학회논문지
    • /
    • 제15권10호
    • /
    • pp.909-913
    • /
    • 2002
  • The luminance and discharge characteristics of ac PDP may be significantly affected by a small amount of impurity gas in working gas. These impurity gases such as O$_2$, O, C and H$_2$ can be mixed in the manufacturing and /or discharge process. In this paper a small amount of impurity gas in acPDP are introduced quantitatively and the relationship between the amount of impurity gas and the luminance/discharge characteristics are investigated. The luminous efficiency decreased seriously with increase in the partial pressure of impurity gases, especially in H$_2$, O$_2$ and CO$_2$. Under the condition of the impurity gas ratio of 2${\times}$10$\^$-3/ for Ar, N2, H$_2$, CO$_2$ and O$_2$, the luminous efficiency decreased about 8%, 8%, 32%, 36% and 50%, respectively.

Relationships Between Impurity Gas and Luminance/Discharge Characteristics of AC PDP

  • Heo, Jeong-Eun;Lee, Sung-Hyun;Kim, Young-Kee;Shin, Jooh-Hong;Yoo, Choong-Hee;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • 제2권4호
    • /
    • pp.29-33
    • /
    • 2001
  • The luminance and discharge characteristics of an AC PDP may be significantly affected by a small amount of impurity gas in working gas. Impurity gases such as $O_2$, O , C and $H_2$ can be mixed in the manufacturing and lor discharge processes. In this paper, a small amount of impurity gas in AC PDP are introduced intertimally and the relationship between the amount of impurity gas and the luminance/discharge characteristics are investigated. The luminous efficiency decreased seriously with the increase in the partial pressure of impurity gases, especially in $H_2$, $O_2$ and $CO_2$, Under the condition of the impurity gas ratio of 2x $10^{-3}$ for Ar, $N_2$, $H_2$, $CO_2$ and $O_2$, the luminous efficiency decreased to about 8%, 8%, 32%, 36% and 50%, respectively.

  • PDF

교류 플라즈마 표시기 방전 시 발생하는 불순물 종의 분석 (An analysis on the impurities generated by discharge in AC plasma display panel)

  • 김광남;김중균;양진호;황기웅;이석현
    • 한국진공학회지
    • /
    • 제8권4A호
    • /
    • pp.482-489
    • /
    • 1999
  • AC PDP(P1asma Display Pane1)s use the mixture of inert gases to generate a discharge inside the display pixels. Impurities such as CO, $CO_2$ and OH inside discharge region may deteriorate the characteristics of PDP operation during long life time of PDP. Electro-negative gas such as CO can cause the sustain pulse amplitude to rise by attaching electrons which will play an important role in the earlier stage of the discharge. MgO film is used to protect the dielectric layer in AC PDP, and is in contact with the free space of display pixel where it is filled with the inert gas mixture. So, MgO film can be a main source of impurities. In this experiment, we observed the change of impurity generation of various MgO films which were deposited by different methods, by using QMS. (quadropole mass spectrometer) The main impurites were $H_2$, CO and $CO_2$. And with the comparison of the TPD (temperature programmed desorption) result, it can be understood that impurity gases are generated by sputtering of MgO surface not by outgassing. Deposition method had effects on the characteristics of the impurity generation. The MgO film manufactured by e-beam evaporation generated more amount of impurity gases than the MgO films manufactured by sputtering or ion-plating. And also heat treatment of MgO film after deposition decreased the magnitude of impurity gas generation.

  • PDF

일반 3차원 표면전하법을 이용한 금속 이물질이 유입된 GIS 내부의 전계 해석 (Analysis of Electric Fields Inside GIS With Metal Impurity Using 3 Dimensional Surface Charge Method)

  • 김용준;민석원;김응식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2117-2119
    • /
    • 1999
  • In this paper, the electric fields inside GIS with metal impurity is analysed by the use of 3 dimensional Surface Charge Method. We find the metal impurity makes electric field distribution inside GIS non-uniform and causes breakdown of $SF_6$ gas in GIS.

  • PDF

Determination of Bi Impurity in Lead Stock Standard Solutions by Hydride-generation Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권2호
    • /
    • pp.233-236
    • /
    • 2004
  • Total impurity analysis of a primary standard solution is one of the essential procedures to determine an accurate concentration of the standard solution by the gravimetry. Bi impurity is determined in Pb standard solutions by inductively coupled plasma mass spectrometry (ICP-MS). The direct nebulization of the Pb standard solution produces a significant amount of the Pb matrix-induced molecular ions which give rise to a serious spectral interference to the Bi determination. In order to avoid the spectral interference from the interferent $^{208}PbH^+$, the hydride generation method is employed for the matrix separation. The Bi hydride vapor is generated by reaction of the sample solution with 1% sodium borohydride solution. The vapor is then directed by argon carrier gas into the ICP after separation from the mixture solution in a liquid-gas separator made of a polytetrafluoroethylene membrane tube. The presence of 1000 ${\mu}$g/mL Pb matrix caused reduction of the bismuthine generation efficiency by about 40%. The standard addition method is used to overcome the chemical interference from the Pb matrix. Optimum conditions are investigated for the hydride-generation ICPMS. The detection limit of this method is 0.5 pg/mL for the sample solutions containing 1000 ${\mu}$g/mL Pb matrix.

글로우방전을 이용한 가스크로마토그라프 검출기의 개발 (Glow Discharge as Detector for Gas Chromatography)

  • 김효진;박일영;장성기;김박광;박만기
    • 약학회지
    • /
    • 제37권1호
    • /
    • pp.76-83
    • /
    • 1993
  • The changes in discharge current, emission and/or oscillation frequency of the electric oscillation of a glow discharge are the potential sensitive measure of the concentration of an impurity in the argon plasma supporting gas. A single jet enhanced glow discharge has been interfaced with the gas chromatograph via 1/8" O.D. tube with a heating pad to study the changes in discharge current. To investigate the optimum operating conditions of the glow discharge system as detector for gas chromatography, pressure, gas flow rate, discharge current, distance between the anode and the cathode have been studied.

  • PDF

불활성 가스의 O2와 CO 불순물 제거를 위한 Ni 촉매의 물성 평가 (Assessment of Ni Catalyst Properties for Removal of O2 and CO Impurity in Inert Gas)

  • 김광배;진새라;김은석;임예솔;이현준;김성훈;노윤영;송오성
    • 한국산학기술학회논문지
    • /
    • 제21권4호
    • /
    • pp.588-595
    • /
    • 2020
  • 반도체 산업용 9N 이상의 초고순도 N2, Ar 등 불활성 가스 제조를 위해 가스 정제공정에 사용되고 있는 Ni 촉매의 물성 평가 및 촉매적 특성을 확인하였다. 조성이 다른 원기둥 형태의 C1, 츄러스 형태의 C2의 두 가지 Ni 촉매에 대해 비교 평가를 진행하였다. Ni 촉매의 형상과 미세구조를 분석하기 위해 광학현미경과 FE-SEM을 이용하였으며, 조성 확인 및 물성을 분석하기 위해 EDS, XRD, 그리고 micro-Raman 분석을 이용하였다. 또한 Ni 촉매의 비표면적 및 촉매적 특성을 확인하기 위해 BET, Pulse Titration 분석을 진행하였다. 조성 분석결과, C1의 경우, 상대적으로 graphite가 불순물로 다량 포함되어 있는 것을 확인하였으며, C2는 C1에 비해 Ni의 함량이 높은 것을 확인하였다. 비표면적 분석 결과, C2의 비표면적이 C1보다 약 1.69배 정도 큰 것을 확인할 수 있었다. 촉매적 특성분석 결과, 상온에서 O2와 CO 불순물 제거 정도가 C2가 우수함을 확인하였다. 따라서 반도체 산업용 초고순도 불활성 기체 제조를 위한 Ni 촉매로는 불순물이 적고, 비표면적이 크며, 상온에서 O2와 CO 제거 성능이 우수한 C2가 적합함을 확인하였다.

우리나라에서 불법 유통되는 메스암페타민의 불순물 프로화일 분석 (Impurity Profiling Analysis of Illicit Methamphetamine Seized in Korea)

  • 유영찬;정희선;김은미;김선춘;김승환
    • 약학회지
    • /
    • 제42권6호
    • /
    • pp.627-633
    • /
    • 1998
  • Impurity profiling analysis of methamphetamine seized in Korea was investigated for the evidential and intelligent purpose. Samples were extracted with ethylacetate which contai ns internal standard of dioctylsebacate under basic condition and extracts were analyzed by GC-FID. Ephedrine, chloroephedrine & 1,2-dimethyl-3-phenylaziridine were identified impurities in illicit methamphetamine by GC-MS. These impurities revealed that most of abused methamphetamine in Korea were synthesized from ephedrine as a starting material. For the classification of samples. firstly, 24 impurity peaks were selected after inspection of every peak in 50 samples as the specific markers of impurities. Secondly, corresponding peak retention time and area ratio to the internal standard were calculated and database was created with values of 24 peaks by in-house program. Finally, cluster analysis was attempted with the resultant profiles using the STAR plot, which was based on the Euclidian distance for evaluating similarity among samples. A total of 76 samples were divided into 8 different groups within 90% statistical similarity and inter-batch samples showed similar impurity patterns by this procedure. In conclusion, the analysis of impurities is a suitable index for estimation the common or different origin of methamphetamine sample.

  • PDF

고분자전해질 연료전지 연료극의 일산화탄소 및 황화수소 농도에 따른 불순물영향에 관한 연구 (A Study on Hydrogen Impurity Effect in Anode of Proton Exchange Membrane Fuel Cell on Various Concentration of CO and H2S)

  • 이은경;백재훈;이정운;이승국;이연재
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.670-676
    • /
    • 2016
  • Hydrogen town in Republic of Korea was established in 2013. Hydrogen as a byproduct produced by various processes of factories is used in hydrogen town facilities. As cell performance is affected by contaminations in fuel gas, various standards about impurities of fuel have been determined by many countries. This study shows performance degradation of single cell with impurities concentrations. Traces of carbon monoxide (CO) and hydrogen sulfide ($H_2S$)can cause considerable cell performance losses. For comparing the performances by poisoning of CO, acceleration test, I-V curve, constant current are performed. Both the CO and $H_2S$ poisoning rate are a function of their concentration. With the higher concentrations the higher poisoning rates are observed. And, it was confirmed that, oxidation behavior and side reaction generation are not affected. Under the lower $H_2S$ concentration condition, the poisoning rate is much higher than that of CO because of its different adsorption intensity. It can be possible that the result of this study can be used for enacting regulation as a baseline data.

ICCD Observation on Discharge Characteristics of 42-in. AC Plasma Display Panel Fabricated by Vacuum Sealing Method

  • Park, Choon-Sang;Tae, Heung-Sik;Kwon, Young-Kuk;Heo, Eun-Gi;Lee, Byung-Hak
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.320-323
    • /
    • 2007
  • The vacuum sealing method is adopted to minimize the residual impurity gas by enhancing a base vacuum level, and the resultant changes in the reset, address, and sustain discharge characteristics, such as a firing voltage, IR emission, and ICCD image, were examined in comparison with the conventional sealing method in the 42-in. AC-PDP. In the PDP cells fabricated by the vacuum sealing method, the ICCD observation illustrates that the discharge is initiated and extinguished very fast and its IR emission intensity is high.

  • PDF