• Title/Summary/Keyword: Impulse tests

Search Result 218, Processing Time 0.024 seconds

The Method of Reinforcing the Immunity of Residual Current Circuit Breaker for the EMC Composite Surge (누전차단기의 EMC 조합서지 내성 강화를 위한 방안)

  • Kim Jae-Chul;Han Yoon-Tak;Kim Oun-Seok;Seol Kyu-Hwan;Kang Jang-Kyou;Moon Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.322-328
    • /
    • 2006
  • In this paper, The impulse un-tripping characteristics and the electro magnetic compatibility characteristics are compared with each other. The performance of impulse un-tripping test exists at domestic standard (KSC 4613). However test items are insufficient because the more test items such as EMC exist at international standard (IEC). Also, Electric Appliances Safety Certificate has taken the certificate test since July 2004 in Korea but did not confirm the EMC performance for RCCBs made in Korea. Thus, in this paper, We experiment with Oscillatory waves immunity test and the 7 EMC tests for 32 RCCBs of 4 types (mini, home standard, plug, outlet) for 16 brands according to IEC standard 61009-1 and 61008-1. As a result, 24 RCCBs proved to be poor for surge immunity test. However the RCCBs operating incorrectly for surge immunity test operate correctly for oscillatory waves immunity test. Thus, the correlation between oscillatory waves immunity test and EMC test is little and standard for compatibility of combination surge at IEC 61000-4-5 should be added to KS standard as soon as possible.

The Lightning Impulse Properties and Breakdown Voltage of Natural Ester Fluids Near the Pour Point

  • Choi, Sun-Ho;Huh, Chang-Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.524-529
    • /
    • 2013
  • Recently, researchers have become interested in natural ester fluids, as they are an environmentally friendly alternative to mineral oils. Natural ester fluids are a natural resource made from plants; they have higher biodegradability, flash, and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester fluids also have a higher pour point, viscosity, and water content. These characteristics can hamper circulation and impair the electrical properties of an oil-filled transformer. A large amount of data has been accumulated over the years in regards to mineral insulating oil involving dielectric breakdown voltage and lightning impulse tests. However, natural ester fluids have not had their electrical properties sufficiently characterized. In this paper, we present an investigation into the characteristics of the electrical discharge development in natural ester fluids and in an oil-filled transformer near the pour points. The experiment results show that the electrical properties decreased according to a decrease in the ambient temperature and freezing time. It was found that the pour point and water content of natural ester fluids have a significant effect on the electrical properties.

A Causality Analysis of the Hairtail Price by Distribution Channel Using a Vector Autoregressive Model (VAR 모형을 이용한 유통단계별 갈치가격의 인과성 분석)

  • Kim, Cheol-Hyun;Nam, Jong-Oh
    • The Journal of Fisheries Business Administration
    • /
    • v.46 no.1
    • /
    • pp.93-107
    • /
    • 2015
  • This study aims to analyze causalities among Hairtail prices by distribution channel using a vector autoregressive model. This study applies unit-root test for stability of data, uses Granger causality test to know interaction among Hairtail Prices by distribution channel, and employes the vector autoregressive model to estimate statistical impacts among t-2 period variables used in model. Analyzing results of this study are as follows. First, ADF, PP, and KPSS tests show that the change rate of Hairtail price by distribution channel differentiated by logarithm is stable. Second, a Granger causality test presents that the producer price of Hairtail leads the wholesale price and then the wholesale price leads the consumer price. Third, the vector autoregressive model suggests that the change rate of Hairtail producer price of t-2 period variables statistically, significantly impacts change rates of own, wholesale, and consumer prices at current period. Fourth, the impulse response analysis indicates that impulse responses of the structural shocks with a respectively distribution channel of the Hairtail prices are relatively more powerful in own distribution channel than in other distribution channels. Fifth, a forecast error variance decomposition of the Hairtail prices points out that the own price has relatively more powerful influence than other prices.

Performance Analysis of the Experimental Liquid Rocket Engine using Liquefied Natural Gas as a Fuel (액화천연가스를 연료로 하는 시험용 액체로켓엔진의 성능해석)

  • 한풍규;이성웅;김경호;윤영빈
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.198-204
    • /
    • 2004
  • Using liquefied natural gas as a fuel, water, natural gas and liquefied natural gas-cooled firing tests were conducted. With the viewpoint of characteristic velocity, and specific impulse, the effect of OF mixture ratio and fuel inlet temperature into a combustion chamber were analyzed. OF mixture ratio and fuel inlet temperature into a combustion chamber have great influence on the performance. Characteristic velocity and theoretical specific impulse attain the maximum value at 0.72~0.75 and 0.75 of OF mixture ratio, respectively. Engine performance has a tendency to increase, proportional to fuel inlet temperature into a combustion chamber affected by the regenerative cooling.

  • PDF

Insulation Characteristics of High Temperature Superconducting Cable (고온 초전도 레이블의 절연 특성)

  • Kim, H.J.;Kim, J.H.;Sim, K.D.;Kim, H.J.;Cho, J.W.;Seong, K.C.;Kwag, D.S.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.244-247
    • /
    • 2004
  • The electrical insulating design is important to realize a HTS power cable because the cable is operated under the high voltage environment. For the insulation design of a HTS power cable, it is necessary to investigate the AC, impulse breakdown and partial discharge(PD) inception stress of liquid nitrogen/LPP composite insulation system. Based on these results, the electrical insulation of a HTS power cable is designed and Mini-model cables are manufactured. The manufactured Mini-model cables are evaluated that AC, impulse withstand voltage, breakdown and partial discharge inception stress and analyzed characteristics insulation of HTS cable bending condition according to this paper. From these tests, the AC, impulse withstand voltage test and partial discharge inception stress is satisfied "standard technical specification of KEPCO" in Korea and the breakdown voltage was 120kV.

  • PDF

Prevalence of Peripheral Vestibular Impairment in Adults with Human Immunodeficiency Virus

  • Millar, Alison;Joubert, Karin;Naude, Alida
    • Korean Journal of Audiology
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2021
  • Background and Objectives: Globally, the human immunodeficiency virus (HIV) is responsible for one of the most serious pandemics to date. The vulnerability of the vestibular system in individuals with HIV has been confirmed, and central vestibular impairments have been frequently reported. However, there are disagreements on the impact of HIV on peripheral vestibular function. Thus, the current study aimed to determine the prevalence of peripheral vestibular impairment, specifically related to the semi-circular canals (SCCs), in HIV-positive individuals receiving antiretroviral (ARV) treatment. Subjects and Methods: A total of 92 adults between the ages of 18 and 50 years (divided into two groups) participated in the study. The first group comprised HIV-positive individuals receiving ARV treatment (n1=60), and the second group comprised HIV-negative participants (n2=32). The video head impulse test was used to conduct the head impulse paradigm (HIMP). Results: Bilateral normal HIMP results were obtained in 95% of the HIV-positive participants and all HIV-negative participants. The gain of the left posterior SCCs was significantly lower in the HIV-positive group, while the gains of all other canals between the two groups were comparable. Conclusions: The prevalence of peripheral vestibular impairment in the HIV-positive group was not significantly different from that of the HIV-negative group. The reduced prevalence in the current study may be attributed to participant characteristics, the test battery employed, and the central compensation of the vestibular dysfunctions at the later stages of infection.

Prevalence of Peripheral Vestibular Impairment in Adults with Human Immunodeficiency Virus

  • Millar, Alison;Joubert, Karin;Naude, Alida
    • Journal of Audiology & Otology
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2021
  • Background and Objectives: Globally, the human immunodeficiency virus (HIV) is responsible for one of the most serious pandemics to date. The vulnerability of the vestibular system in individuals with HIV has been confirmed, and central vestibular impairments have been frequently reported. However, there are disagreements on the impact of HIV on peripheral vestibular function. Thus, the current study aimed to determine the prevalence of peripheral vestibular impairment, specifically related to the semi-circular canals (SCCs), in HIV-positive individuals receiving antiretroviral (ARV) treatment. Subjects and Methods: A total of 92 adults between the ages of 18 and 50 years (divided into two groups) participated in the study. The first group comprised HIV-positive individuals receiving ARV treatment (n1=60), and the second group comprised HIV-negative participants (n2=32). The video head impulse test was used to conduct the head impulse paradigm (HIMP). Results: Bilateral normal HIMP results were obtained in 95% of the HIV-positive participants and all HIV-negative participants. The gain of the left posterior SCCs was significantly lower in the HIV-positive group, while the gains of all other canals between the two groups were comparable. Conclusions: The prevalence of peripheral vestibular impairment in the HIV-positive group was not significantly different from that of the HIV-negative group. The reduced prevalence in the current study may be attributed to participant characteristics, the test battery employed, and the central compensation of the vestibular dysfunctions at the later stages of infection.

A Study on the Backcalculation of Layer Moduli of Asphalt Pavement System by Contemplating the Depth to Virtual Bedrock (가상암반층의 깊이를 고려한 아스팔트 포장체의 층별 탄성계수 추정기법의 개발)

  • Kim, Soo Il;Lee, Kwang Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.87-99
    • /
    • 1993
  • The computer program, MFPD, which is used to backcalculate the layer moduli of asphalt concrete pavement system is modified by contemplating the depth to virtual bedrock in this study. An algorithm to estimate the depth to virtual bedrock is developed through the analysis of FWD impulse load duration and the compression wave velocity of ground. For verification of the modified MFPD, FWD is fabricated and then FWD field tests and verification tests are carried out at the test sites. Plate loading tests and surface wave propagation tests are performed at FWD test sites. Laboratory tests (Marshall stability tests, unconfined compression tests) for sampled asphalt concrete specimens are also carried out. From comparison analysis, the validity and applicability of the modified MFPD are verified.

  • PDF

Development of a Consumption Self-regulation Scale (소비에 대한 자기조절척도 개발)

  • Nam, Su-Jung
    • Journal of Families and Better Life
    • /
    • v.24 no.5 s.83
    • /
    • pp.175-189
    • /
    • 2006
  • The purpose of this study was to develop a standardized scale to measure consumption self-regulation. A preliminary 38-item scale was developed through a literature review. One thousand-twelve consumers responded to an online survey using the preliminary scale. A series of tests, such as test-retest, item-to-total correlation, Cronbach's reliability coefficient and factor analysis, were conducted using the survey data and a final scale comprising 30 items was then constructed. The consumption self-regulation scale consisted of four factors: (1) impulse control, (2) gratification delay, (3)self-reliance, and (4) self-management.

Passive Control for the Augmentation of a Pulse Wave (펄스파 강도증가를 위한 피동제어)

  • 이동훈;김희동;강성황
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.241-248
    • /
    • 2001
  • The present paper describes experimental and computational work to augment the magnitude of the impulsive wave. An experiment was performed using a simple shock tube with an open end and numerical calculations were carried out to solve the unsteady, axisymmetric, inviscid, compressible governing equations. The control strategy applied was to alter the exit geometry of a straight tube to a sudden enlargement tube and a flare tube. The effects of the configurations of the tube exit on the magnitude of the impulsive wave were investigated over the range of the weak shock Mach number from 1.01 to 1.10. The results obtained were compared to those of the straight tube tests. The numerical result predicted the magnitude of the experimented impulsive waves with a good accuracy. The present passive control technique enabled the magnitude of the impulsive wave to augment by about 23 percent, compared to that of the straight tube of no control.

  • PDF