• Title/Summary/Keyword: Impulse load

Search Result 136, Processing Time 0.036 seconds

The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

Sensing performance evaluation under various environment condition of stroke sensing cylinder using magnetic sensor (자기센서를 이용한 위치검출 실린더의 환경변화에 따른 성능평가)

  • 김성현;이민철;양순용
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.636-639
    • /
    • 1996
  • We have developed a part of hydraulic stroke sensing cylinder using magnetic sensor that can detect each position under severe construction fields. In this paper, for evaluating the developed cylinder under various environment condition, thermal control systems and two hydraulic systems to be coupled consist of. The former is composed of an heater case, temperature sensor, and interface circuits which include SCR(silicon controlled rectifier) for the control of the voltage's phase. The latter is composed of an hydraulic cylinder for position control with solenoid valve (ON/OFF motion) and a load cylinder with proportional reducing valve. To obtain the various performance evaluation, it is carried out under high temperature condition in thermal system controlled by using Ziegler-Nichols PID tuning method and artificial disturbances such as impulse or constant force. The results show that the developed cylinder has good performance under the various environment condition.

  • PDF

The dynamic stability of a nonhomogeneous orthotropic elastic truncated conical shell under a time dependent external pressure

  • Sofiyev, A.H.;Aksogan, O.
    • Structural Engineering and Mechanics
    • /
    • v.13 no.3
    • /
    • pp.329-343
    • /
    • 2002
  • In this research, the dynamic stability of an orthotropic elastic conical shell, with elasticity moduli and density varying in the thickness direction, subject to a uniform external pressure which is a power function of time, has been studied. After giving the fundamental relations, the dynamic stability and compatibility equations of a nonhomogeneous elastic orthotropic conical shell, subject to a uniform external pressure, have been derived. Applying Galerkin's method, these equations have been transformed to a pair of time dependent differential equations with variable coefficients. These differential equations are solved using the method given by Sachenkov and Baktieva (1978). Thus, general formulas have been obtained for the dynamic and static critical external pressures and the pertinent wave numbers, critical time, critical pressure impulse and dynamic factor. Finally, carrying out some computations, the effects of the nonhomogeneity, the loading speed, the variation of the semi-vertex angle and the power of time in the external pressure expression on the critical parameters have been studied.

Spatially filtered multi-field responses of piezothermoelastic cylindrical shell composites

  • Tzou, H.S.;Bao, Y.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.2
    • /
    • pp.111-124
    • /
    • 1996
  • New active "intelligent" structural systems with integrated self-sensing, diagnosis, and control capabilities can lead to a new design dimension for the next generation high-performance structures and mechanical systems. However, temperature effects to the piezoelectric transducers are not fully understood. This paper is concerned with a mathematical modeling and analysis of a laminated piezothermoelastic cylindrical shell composite exposed to mechanical, electric, and thermal fields. Generic shell equations and solution procedures are derived. Contributions of spatial and time components in the mechanical, electric, and temperature excitations are discussed, and their analytical solutions derived. A laminated cylindrical shell composite with fully distributed piezoelectric layers is used in a case study; its multi-field step and impulse responses are investigated. Analyses suggest that the fully distributed actuators are insensitive to even modes due to load averaging and cancellation. Accordingly, these even modes are filtered from the total response and only the modes that are combinations of m = 1, 3, 5, ${\cdots}$ and n = 1, 3, 5, ${\cdots}$ participating in dynamic response of the shell.

The numerical analysis of heavy-weight impact noise for an apartment houses considering acoustic mode (Acoustic mode 를 고려한 공동주택 중량충격음 소음해석)

  • Mun, Dae-Ho;Hwang, Jae-Seung;Park, Hong-Gun;Hong, Geon-Ho;Im, Ju-Hyeuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.394-402
    • /
    • 2009
  • To investigate the heavy-weight impact noise of apartment houses, numerical analysis was performed. The analysis acoustic pressure consider acoustic mode by finite element method. The variables considered effecting on the acoustic pressure are the Acoustic mode, acoustic damping, and the impulse load. The heavy-weight impact noise is a changeable value in the room. Since the most part of the frequency component of heavy-weight impact noise has low frequency. The noise in low frequency is related to the vibration of structure, the reflection of acoustic wave caused by wall and the standing wave called by acoustic mode. The prediction by the numerical analysis was verified with test result of the heavy weight-impact noise at apartment houses.

  • PDF

Analysis of Impact load for the container loaded trailer (컨테이너가 상차될 때 트레일러가 받는 충격하중 해석)

  • 김재헌;홍도관;김중완;전언찬;안찬우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.277-281
    • /
    • 1997
  • Reliab~l~ty englneerlng IS regarded as the major and important roll for all Industry And advanced nianufactur~ng systems w~th h~gh speed and lntell~gent ha\\ulcorner been dcvelop~ng for betterment of lnachln~ng db~l~ty In th~study, Me have rystem~~ed c\, ~luat~on c r f relidb~litl for nldchlntry system We proposed the rel~ab~l~ty asvxmcnt and dci~yned and manufactured r~ildb~llty tcst-bed to eualuate rcl~dbil~ty In ddd~t~on we acquired relldb~l~ty data uslng test-bed sydem and mde database to handle relrab~l~t) data And also he not only use rel~ab~l~ty data by andlyzlng rel~ab~l~ty, but also apply design revlew method usmg analycing crltlcal unlt5 of machlnery system From th~s stud), he u ~ l l expect to gu~de md Increase the rel~ab~l~t) englneerlng in devclop~ng and procerslng phase of h~gh qualrty product

  • PDF

Faults Detection in Hub Bearing with Minimum Variance Cepstrum (최소 분산 켑스트럼을 이용한 자동차 허브 베어링 결함 검출)

  • 박춘수;최영철;김양한;고을석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.593-596
    • /
    • 2004
  • Hub bearings not only sustain the body of a car, but permit wheels to rotate freely. Excessive radial or axial load and many other reasons can cause defects to be created and grown in each component. Therefore, vibration and noise from unwanted defects in outer-race, inner-race or ball elements of a Hub bearing are what we want to detect as early as possible. How early we can detect the faults has to do with how the detection algorithm finds the fault information from measured signal. Fortunately, the bearing signal has periodic impulse train. This information allows us to find the faults regardless how much noise contaminates the signal. This paper shows the basic signal processing idea and experimental results that demonstrate how good the method is.

  • PDF

Study on the Flying Stab3B3ty of the FEMTO(20%) Slider (FEMTO(20%) 슬라이더의 부상안정성 고찰)

  • 강태식;이철우;조긍연;정재명;정준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.887-887
    • /
    • 2004
  • The areal density of the hard disk drive(HDD) has been increased due to technological advances recently. To achieve the high areal density magnetic recording requires an extremely small gap between the air-bearing surface (ABS) and disk. At the same time, the slider mass and size should be reduced to minimize the physical contact under the operational and environmental conditions. Almost all of 2.5"HDD companies will get ready for adoption of FEMTO slider and already utilized the small slider. FEMTO and small size slider will be mainstream in the 2.5" and other small form factor HDD in the near future. In this study, the flying characteristic of FEMTO slider was examined. Based on the simulation, FEMTO slider is very stable in flying dynamic under the disk modulation, however the flying height sensitivity of the manufacturing tolerances is much bigger than PICO slider. And the other characteristics like impulse response and load/unload dynamic were also examined in this study.tudy.

  • PDF

A Study on the reliability analysis of Forest Fire on Polymer Insulators (폴리머 애자의 산불 신뢰성 평가 연구)

  • Lee, Won-Kyo;Choi, In-Hyuk;Hwang, Kab-Cheol;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.460-461
    • /
    • 2008
  • The forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

  • PDF

Improving Quick Response of Servo System Using Boost-Diverter with Regenerating Energy (회생에너지의 부스트인버터 구동방식을 적용한 서보시스템의 응답특성 향상)

  • Kim Tae-Woong;Choi Jae-Ho;Min Wan-Ki;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.339-341
    • /
    • 2006
  • The regenerating energy of the servo system is mostly consumed as heats through the regenerating resistors. For the response of the servo system to be more improved, the paper proposes the boost inverter using the regenerating energy, The proposed boost inverter has the additional capacitor installed on the DC-link circuit for charging the regenerating energy from the load. To get the better response of the servo system, the charged regenerating energy can be shortly re-applied to the output side as the finite impulse voltage, which can be controlled from information of reference voltages and feedbacked currents. It is verified by PSIM simulator that the response characteristics of the servo system using the proposed boost inventer is improved, comparing to that using the general inverter.

  • PDF