• 제목/요약/키워드: Improvement efficiency

Search Result 5,558, Processing Time 0.044 seconds

Prediction of Potential $CO_2$ Reduction through Ground Transportation Modal Shift with Fu7el Type and Scenarios (연료원별 온실가스배출량을 고려한 육상교통수단에서의 Modal Shift 효과)

  • Kim, Cho-Young;Lee, Cheul-Kyu;Kim, Yong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.521-527
    • /
    • 2011
  • Korea announced GHG reduction goal, 30% reduction compare with 2020 BAU and reduction target for each industry sector is planning. Transportation sector also trying to make effective technical and political counterplan of allocated GHG reduction target such as material lightening, energy efficiency improvement and Modal shift technology and so on. Modal Shift is shifting low energy efficiency vehicle to high energy efficiency vehicle which is economically meaningful under current market conditions. We can get not only energy efficiency improvement but also GHG reduction effect through modal shift. Modal Shift is effectively applying and studied in logistics field in Europe and Japan and one of the Indian companies has been registered CDM project activity involving modal shift from roadways to railways for finished goods. In this study, the scenarios are developed with detail modal shift ratio and fuel type base on state of road and rail use and GHG emission factor for each fuel type from MLTM. This result can be used as basic information to improve policies and promote increasing use of train which is more environment friendly transportation vehicle.

  • PDF

Improvement of free-space optical interconnection efficiency by using circular aperture CGH

  • Shin, Chang-Mok;Seo, Dong-Hoan;Cho, Kyu-Bo;Kim, Cheol-Su;Lee, Ha-Woon;Kim, Soo-Joong
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.9-11
    • /
    • 2002
  • We improve the free-space optical interconnection efficiency by using circular aperture computer-generated hologram (CGH). In free-space optical interconnection system using CGH, the single CGH is composed of sub-CGHs, which can change the direction of input beams to desired output positions, by Fourier transform. Each sub-CGH is rectangular shape, so the input beams through each sub-CGH are transformed to sinc functions in output plane. The side lobes of each sinc function are superimposed in output plane and they result in detection error in output plane, so the detection efficiency is low. We use the circular shaped sub-CGHs in order to reduce the side lobe value in output plane instead of rectangular shaped sub-CGHs. The each input beam is transformed to first-order Bessel functions through circular shaped sub-CGHs in output plane. The side lobes of first-order Bessel functions us low values compared with side lobes of sinc function, so we can improve the detection efficiency in output plane. We use binary phase modulated CGH, and confirm this improvement results by simulation.

  • PDF

Energy Conversion Efficiency Improvement of Piezoelectric Micropower Generator Adopting Low Leakage Diodes (저누설 다이오드를 사용한 저전력 압전발전기의 효율 개선에 관한 연구)

  • Kim, Hye-Joong;Kang, Sung-Muk;Kim, Ho-Seong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.938-943
    • /
    • 2007
  • In this paper, we show that, in case of piezoelectric micropower generator, just replacing Schottky diodes in the bridge rectifier with ultra-low reverse leakage current diodes improves the mechanical-to-electrical energy conversion efficiency by more than 100%. Experimental and PSPICE simulation results show that, due to the ultra-low leakage current, the charging speed of the circuit employing PAD1 is higher than that of the circuit employing Schottky diodes and the saturation voltage of the circuit employing PAD1 is also higher. This study suggests that , when the internal impedance of source is very large (a few tens of $M{\Omega}$) such that maximum charging current is a few microamperes or less, in order to realize literally the energy scavenging system, ultra-low reverse leakage current diodes should be used for efficient energy conversion. Since low-level vibration is ubiquitous in the environment ranging from human movement to large infrastructures and the mechanical-to-electrical energy conversion efficiency is much more critical for use of these vibrations, we believe that the improvement in the efficiency using ultra-low leakage diodes, as found in this work, will widen greatly the application of piezoelectric micropower generator.

Current-Voltage-Luminance Characteristics of Organic Light-Emitting Diodes with a Variation of PVK Concentration Used as a Buffer Layer (버퍼층으로 사용한 PVK의 농도 변화에 따른 유기 발광 소자의 전압-전류-휘도 특성)

  • Kim, Sang-Keol;Hong, Jin-Woong;Kim, Tae-Wan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.68-72
    • /
    • 2002
  • We have seen the effects of buffer layer in organic light-emitting diodes(OLEDs) using poly(N-vinylcarbazole)(PVK) depending on a concentration of PVK. Polymer PVK buffer layer was made using spin casting technique. Two device structures were fabricated; one is ITO/TPD/$Alq_{3}$/Al as a reference, and the other is ITO/PVK/TPD/$Alq_{3}$/Al to see the effects of buffer layer in organic light-emitting diodes. Current-voltage-luminance characteristics and an external quantum efficiency were measured with a variation of spin-casting rpm speeds and PVK concentration. We have obtained an improvement of external quantum efficiency by a factor of four when the PVK concentration is 0.1wt% is used. The improvement of efficiency is expected due to a function of hole-blocking of PVK in OLEDs.

Efficiency Improvement of OLEDs with a Variation of Cathodes (음전극 변화에 따른 유기 발광 소자의 효율 향상)

  • Kim, S.K;Chung, D.H.;Chung, T.G.;Lee, H.S.;Jang, K.U.;Choi, M.G.;Hong, Jin-Ung;Lee, J.U.;Kim, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1038-1041
    • /
    • 2002
  • We have investigated the effects of cathode in organic light-emitting diodes of ITO/TPD/$Alq_3$/Cathodes(Al, LiF/Al, Ca/Al, and LiAl) by measuring current-voltage-luminance characteristics. The device with cathodes other than Al cathode shows the efficiency by an oder of one compared with Al cathode only. This improvement is due to a reduction of barrier height in cathode side.

  • PDF

A Performance Investigation and Comparison of Line Start-up Permanent Magnet Synchronous Motor with Super Premium Efficiency

  • Feng, Xueqing;Bao, Yaxin;Liu, Lijun;Huang, Lizhong;Zhang, Yingming
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.30-37
    • /
    • 2012
  • This paper presents the performance investigation and design technology of a Line Start-up Permanent Magnet Synchronous Motor (LSPMSM) with super premium efficiency, including a design consideration and evaluation for motor start-up, key performance, and advanced finite element analysis FEA) for the design, improvement and verification, prototype build and test, design and test data comparison with a $Premium^{(R)}$ Efficient Induction Motor (PEIM). To assess the design technology, the LSPMSM prototype was built amended from a PEIM with the same frame, stator punching and rated output. Based on the prototype test, two novel design improvements and analyses have been done to eliminate noise and vibration. Additionally, the comparisons with the PEIM on the power factor, efficiency, frame size and active material consumption indicated that a significant performance improvement and active material cost reduction can be achieved by the LSPMSM.

Improvement of treatment efficiency for sanitary treatment facilities by process modifications (분뇨처리장의 공정개선에 의한 처리효율 향상에 관한 연구)

  • Lee, Chan Won;Kim, Seung Hyeon;Kim, Chang Su;Mun, Seong Won;Jeon, Hong Pyo;Yun, Jong Seop
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.571-579
    • /
    • 2004
  • There is a need to improve the efficiency of the existing sanitary treatment facilities, because the effluent standard becomes more stricter and septic sludge increased. Thus, operating processes of sanitary treatment system in M city changed with installation of additional facilities. Process modifications were as follows: Dilution water was added to the next process after primary aeration tank. Some secondary sedimentation sludge was recycled to primary aerator so that most of the organics were stabilized in primary aeration tank under automatic control of dissolved oxygen. The line of effluent from dewatering process flowing to the activated sludge tank was changed to the primary aerator. The primary sedimentation sludge line was linked to a thickener. Polymer was added to the activated sludge tank. The effluent of primary aerator and aerobic digester was recycled from the 5th to the 1st sector. As consequencies of above process modifications, the improvement of removal efficiency was achieved as BOD 54%, COD 42%, SS 61%, T-N 39%, and T-P 12%, respectively.

Pipeline-Aware QC-IRA-LDPC Code and Efficient Decoder Architecture (Pipeline-Aware QC-IRA-LDPC 부호 및 효율적인 복호기 구조)

  • Ajaz, Sabooh;Lee, Hanho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.72-79
    • /
    • 2014
  • This paper presents a method for constructing a pipeline-aware quasi-cyclic irregular repeat accumulate low-density parity-check (PA-QC-IRA-LDPC) codes and efficient rate-1/2 (2016, 1008) PA-QC-IRA-LDPC decoder architecture. A novel pipeline scheduling method is proposed. The proposed methods efficiently reduce the critical path using pipeline without any bit error rate (BER) degradation. The proposed pipeline-aware LDPC decoder provides a significant improvement in terms of throughput, hardware efficiency, and energy efficiency. Synthesis and layout of the proposed architecture is performed using 90-nm CMOS standard cell technology. The proposed architecture shows more than 53% improvement of area efficiency and much better energy efficiency compared to the previously reported architectures.

A Study on the Efficiency Improvement of Linear Power Amplifier for Mobile Communication Repeater Applications (이동 통신 중계기용 선형 전력 증폭기 효율 개선에 관한 연구)

  • An, Jeong-Sig;Lee, Jong-Arc
    • Journal of IKEEE
    • /
    • v.3 no.2 s.5
    • /
    • pp.215-220
    • /
    • 1999
  • In fabricated linear power amplifier(LPA), the third-order inter-modulation distortion(IMD) for main amplifier alone is 10.61dBc, and the IMD for LPA with predistorter and feedforward loop combined is 32.50dBc. Therefore, the IMD characteristic results an improvement of approximately 22dB. The main amplifier efficiency with single tone input is close to 30%, and the efficiency of the overall LPA with predistorter is 27.4% and predicted feedforward loop efficiency without predistorter is about 20%. Therefore, LPA with predistorter and feedforward loop combined is improved by 7.4%.

  • PDF

On the Improvement of the Combustibility of Waste Plastics used in Blast Furnace

  • Ban, Bong-Chan;Choi, Jin-Shik;Kim, Dong-Su
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.751-754
    • /
    • 2001
  • A possibility of using waste plastics as a source of secondary fuel in blast furnace has been of recent interest. The success of this process, however, will be critically dependent upon the optimization of operating systems. for instance, the supply of waste plastics must be reliable as well as economically attractive compared with conventional secondary fuels such as heavy oil, natural gas and pulverized coal. In this work, we put special importance on the improvement of the combustibility of waste plastics as a way to enhance energy efficiency in blast furnace. As experimental variables to approach this target, the effects of plastic particle size, blast temperature, and the level of oxygen enrichment were investigated using a custom-made blast model designed to simulate a real furnace. Lastly, the combustion efficiency of the mixture of waste plastics and pulverized coal was tested. The observations made from these experiments led us to the conclusion that with the increase of both blast temperature and the level of oxygen enrichment, and with the decrease of particle size, the combustibility of waste PE could be improved at a given distance from tuyere. Also it was found that the efficiency of coal combustion decreased with the addition of plastics; however, the combustion efficiency of mixture could be comparable at longer distance from tuyere.

  • PDF