• Title/Summary/Keyword: Impression material

Search Result 202, Processing Time 0.021 seconds

DIMENSIONAL STABILITY OF IMPRESSION BODY USING THE SILICONE INDEX TOOTH TRAY IMPRESSION SYSTEM

  • Lee, Kyu-Young;Jeong, Seung-Mi;Shim, June-Sung;Choi, Byeong-Gap;Lee, Keun-Woo;Kim, Han-Sung
    • Journal of Korean Dental Science
    • /
    • v.1 no.1
    • /
    • pp.22-27
    • /
    • 2008
  • Purpose : This study sought to evaluate the dimensional stability of the SITT (Silicone Index Tooth Tray) impression system and to determine whether providing space for wash impression material in SITT is a necessary step in obtaining accurate prostheses. Materials and methods : After mounting metal dies with shoulder and chamfer margins arbitrarily, SITT was fabricated using Blu-mousse$^{(R)}$. To test the dimensional stability of the SITT system for margin design, the shoulder margin and chamfer margin were evaluated. Furthermore, to test the effect of space for wash impression material, 0.5mm space in SITT and zero space in SITT were statistically compared. Results : 1. There was no significant difference between the group with shoulder margin and that with chamfer margin. 2. There was no significant difference between the group with 0.5mm space and that with zero space for wash impression material. Conclusions : Considering the limitations of this study, the dimensional stability of the SITT system did not interfere with the margin design. Space for the wash impression material was also unnecessary.

  • PDF

AN EVALUATION OF THE TIME-DEPENDENT DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS (인상채득 후 시간경과에 따른 고무인상재의 체적변화)

  • Lee Hong-Seok;Cho Suck-Kyu;Yoon Tae-Ho;Park Ju-Mi;Song Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.363-373
    • /
    • 2006
  • Statement of Problem : The accuracy and dimensional stability of elastomeric impression materials have been the subject of numerous investigation. Few studies have addressed the effect of changes in time on the dimensional stability of impression materials. Purpose: The purpose of this investigation was to evaluate the effects of elastomeric impression materials and storage time on dimensional stability. Materials and methods: A total of 75 impressions were made of epoxy resin dies mimicked prepared 3-unit fixed partial denture. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines and interpreped dot. Impression materials investigated included two polyether impression materials and three polyvinylsiloxane impression material. 15 specimens were made of each impression material and poured by type IV stone over times (30 minutes, 24 hours, 72 hours) after mixing; the same examiner measured each specimen 3 times at a magnification of 3.5$\times$. All statistical tests were performed with the level of significance set at .05. Results : The results indicated that significant difference at any measuring point of stone dies of the polyether impression materials and when measurements at 30 minutes, 24 hours, and 72 hours were compared ; the length of measuring point increased significantly as time passed by. However this result is not significant clinically. Analysis also showed significant differences at any measuring point when polyvinylsiloxane and polyether impression materials were compared and significant differences clinically. Conclusion: Under the conditions of this study, the shrinkage rate of the polyvinylsiloxane and polyether impression materials significantly increased as time passed by. The polyether impression materials showed higher shrinkage significantly, while the shrinkage rate of all five materials showed a significant time-dependent increase.

Comparison of mechanical properties and flowability of dental impression materials (치과용 인상재의 기계적 물성 및 흐름성 비교)

  • Kim, Ji-Yeob;Song, Kun-Ho;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.36
    • /
    • pp.39-43
    • /
    • 2016
  • The purpose of this study is to determine and compare the mechanical and flow properties of polyvinylsiloxane impression pastes. Twelve polyvinylsiloxane impression materials were used. As mechanical properties, tensile strength and tear resistance were measured. Impression materials are subjected to tensile stresses when they are removed from the oral cavity and from stone models and tear resistance is the ability of the material to resist tearing under a tensile stress. Flow is dependent on the ability of the material to resist shear forces. Flow tests were performed to determine the handling characteristics and was measured using a shark fin testing device. An impression material must be able to penetrate the narrow subgingival sulcus and tight interproximal areas. Therefore, it must be able to resist the shear forces as it is pushed between tooth and gingival walls. It is necessary to understand the properties of interocclusal recording materials and is considered that the results obtained in this study will provide guideline information for the manufacturing of impression materials and for selecting appropriate impression materials.

  • PDF

A COMPARATIVE STUDY ON THE ACCURACY OF IMPRESSION METHOD USING ADDITION SILICONE PUTTY IMPRESSION MATERIAL (부가중합형 Silicone putty 인상재를 이용한 인상채득 방법의 정확성에 관한 연구)

  • Je, Hong-Ji;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.373-383
    • /
    • 1996
  • In order to compare the accuracy of impression method using addition silicone putty impression material, metal master die was fabricated with 4 cylindrical abutments that were similar in shape to mandibular arch. Among the 4 abutments, two(A, D) with 8mm width and 7mm height were formed in the 2nd molar regions and the other two(B, C) with 6mm width and 7mm height were on the canine regions. Impressions were taken using one-step putty wash impression technique and two-step putty wash impression technique by three different types of impression materials(Perfect, Express, Exaflex). Upon measuring the distance between the abutments on the model by three dimensional measuring machine, the percent of devitaion of the materials were obtained, rendering the following results. The results obtained are as follows : 1. There was no significant difference in accuracy in regard with the impression method between one-step putty wash impression technique and two-step putty wash impression technique using addition silicone putty impression material. 2. There were no difference in accuracy among with three different addition silicone putty impression materials. 3. All the distances between abutments on improved stone models increased in comparison with those on the metal master model.

  • PDF

Drying time of tray adhesive for adequate tensile bond strength between polyvinylsiloxane impression and tray resin material

  • Yi, Myong-Hee;Shim, Joon-Sung;Lee, Keun-Woo;Chung, Moon-Kyu
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.63-67
    • /
    • 2009
  • STATEMENT OF PROBLEM. Use of custom tray and tray adhesive is clinically recommended for elastomeric impression material. However there is not clear mention of drying time of tray adhesive in achieving appropriate bonding strength of tray material and impression material. PURPOSE. This study is to investigate an appropriate drying time of tray adhesives by evaluating tensile bonding strength between two types of polyvinylsiloxane impression materials and resin tray, according to various drying time intervals of tray adhesives, and with different manufacturing company combination of impression material and tray adhesive. MATERIAL AND METHODS. Adhesives used in this study were Silfix (Dentsply Caulk, Milford, Del, USA) and VPS Tray Adhesive (3M ESPE, Seefeld, Germany) and impression materials were Aquasil Ultra (monophase regular set, Dentsply Caulk, Milford, Del, USA) and Imprint II Garant (regular body, 3M ESPE, Seefeld, Germany). They were used combinations from the same manufacture and exchanged combinations of the two. The drying time was designed to air dry, 5 minutes, 10 minutes, 15 minutes, 20 minutes, and 25 minutes. Total 240 of test specimens were prepared by auto-polymerizing tray material(Instant Tray Mix, Lang, Wheeling, Il, USA) with 10 specimens in each group. The specimens were placed in the Universal Testing machine (Instron, model 3366, Instron Corp, University avenue, Nowood, MA, USA) to perform the tensile test (cross head speed 5 mm/min). The statistically efficient drying time was evaluated through ANOVA and Scheffe test. All the tests were performed at 95% confidence level. RESULTS. The results revealed that at least 10 minutes is needed for Silfix-Aquasil, and 15 minutes for VPS Tray Adhesive-Imprint II, to attain an appropriate tensile bonding strength. VPS Tray Adhesive-Imprint II had a superior tensile bonding strength when compared to Silfix-Aquasil over 15 minutes. Silfix-Aquasil had a superior bonding strength to VPS Tray Adhesive-Aquasil, and VPS Tray Adhesive-Imprint II had a superior tensile bonding strength to Silfix-Imprint II at all drying periods. CONCLUSION. Significant increase in tensile bonding strength with Silfix-Aquasil and VPS Tray adhesive-Imprint II combination until 10 and 15 minutes respectively. Tray adhesive-impression material combination from the same company presented higher tensile bonding strength at all drying time intervals than when using tray adhesive-impression material of different manufactures.

Fundamental Study for Developing Silicone Rubber Impression Material (실리콘 고무인상재 개발을 위한 기초연구)

  • Oh, Young-Il;Han, Kyung-A;Kim, Kyung-Nam;Cho, Lee-Ra;Chung, Kyung-Ho
    • Elastomers and Composites
    • /
    • v.35 no.1
    • /
    • pp.19-28
    • /
    • 2000
  • The fundamental study of additional silicone impression material has been performed by comparing the other import products. In order to estimate the possibility of usage of the impression material developed in this study, the several techniques such as IR, EDX, DSC, TGA, rubber rheometer, and contact angle measurement were used. According to the results, there were not any product satisfying all properties required in the impression material. The impression material developed in this study showed best mechanical properties among the all impression materials. However. the wetting property should be studied more by an introduction of a hydrophilic surfactant or modification of a base polymer.

  • PDF

Application study of silicon impression material for reducing metal artifacts: preliminary study for head and neck cancer radiotherapy

  • So Hyun Park;Jinhyun Choi;Byungdo Park;Jeongho Kim;Heesoo Lim;Dae-Hyun Kim
    • Journal of Medicine and Life Science
    • /
    • v.20 no.2
    • /
    • pp.83-88
    • /
    • 2023
  • Metal artifacts cause inaccuracies in target delineation, radiation treatment planning, and delivery when computed tomography images of a radiotherapy patient implanted with a high-density material in the body are acquired. In this study, we investigated the possibility of obtaining improved images in clinical trials through metal artifact reduction using silicon impression materials without the need for a specific metal artifact reduction algorithm. A silicon impression material exhibiting a constant Hounsfield unit (HU) value according to the mixing ratio of the catalysts and bases was selected. The material did not exhibit any change in weight or shape over time. For both the instances of inserting the metal material and applying the silicon impression material, the HU value and dose were compared with homogeneous cases filled with water-equivalent materials. When the silicon impression material was applied to the region where the high-density material was located, the HU value was within 5% and the dose was within 3% compared with those of the homogeneous cases. In this study, the silicon impression materials reduced metal artifacts. However, because the composition, shape, size, and location of high-density materials differ, further studies are required to consider these factors in clinical applications.

Clinical considerations of impression making for edentulous patients (성공적인 총의치 제작을 위한 단계별 포인트 - 무치악인상채득, 이것이 핵심이다.)

  • Park, Chan-Jin
    • The Journal of the Korean dental association
    • /
    • v.55 no.1
    • /
    • pp.72-81
    • /
    • 2017
  • Regardless of the type of impression being made, the tray is the most important part of the impression-making procedure for completely edentulous patients. Dentists have to make use of a combination of rigid, thermoplastic, and resilient materials and control step-by-step procedure from irreversible hydrocolloid impression to definitive cast fabrication. For successful edentulous impression, some considerable clinical tips were guided.

  • PDF

Effect of Filler on the Physical Properties of Silicone Rubber Impression Material (실리콘 고무인상재의 물성에 미치는 충전제의 영향)

  • Chung, Kyung-Ho;Kang, Seung-Kyung
    • Elastomers and Composites
    • /
    • v.41 no.3
    • /
    • pp.157-163
    • /
    • 2006
  • In this study, the wettability and mechanical properties of silicone rubber impression material were studied by using precipitated silica and fumed silica with different particle size and polarity (hydrophilic/hydrophobic). Curing time of impression material depended on the particle size of fumed silica. The curing time delayed about 9 minutes by using A300, which was the fumed silica with the smallest particle size among the silica used in this study. Wettability of rubber impression material improved with the introduction oi hydrophobic fumed silica(R972). Also, the optimum flow and mechanical properties could be obtained by using blended silica with the 90: 10 ratio of precipitated and fumed silica.

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.