• Title/Summary/Keyword: Implantable system

Search Result 119, Processing Time 0.023 seconds

Manufacture of Custom IC and System for Multi-channel Biotelemeter (다채널 바이오텔레미터 개발을 위한 전용 IC 및 시스템 제작)

  • 서희돈;박종대
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.172-180
    • /
    • 1994
  • Implantable biotelemetry systems are indispensable tools not only in animal research but also in clinical medicine as such systems enable the acquisition of otherwise unavailable physiological data. We present the manufacture of CMOS IC and its system for implantable multichannel biotelemeter system. The internal circuits of this system are designed not only to achieve as multiple functions and low power dissipation as possible but also to enable continuous measurement of physiological data. Its main functions are to enable continuous measurement of physiological data and to accomplish on-off power swiching of an implantable battery by receiving appropriate commanc signals from an external circuit. The implantable circuits of this system are designed and fabricated on a single silicon chip using $1.5\mu$m n-well CMOS process technology. The total power dissipation of implantable circuits for a continuous operation was 6.7mW and for a stand-by operation was 15.2$\mu$ W. This system used together with approriate sensors is expected to contribute to clinical medicine telemetry system of measuring and wireless transmitting such significant physiological parameters as pressure pH and temperature.

  • PDF

Design of Vibrating Transducer for Implantable Middle Ear Hearing Aid (이식형 중이 청각보조기를 위한 진동 트랜스듀서의 설계)

  • 박형욱
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.535-544
    • /
    • 1996
  • In this paper, we analyzed the coil-magnet type vibrating transducer for the implantable middle ear hearing aid which is appropriate for patient's hearing level, and an experimental transducer system is designed For the objective and quantitative analysis of the transducer, a theoretical equivalent model containing coil, magneto and inner ear is developed To perform effective evaluation of the transducer, a transforming ratio Tr is introduced and its range that is suitable for practical implantable middle ear hearing device is foun4 The result of applying physical parameters of ear system to the proposed analytical model shows that frequency response of the coil magrlet type vibrator is predominantly governed by resistive impedance of the coil rather than inertia effect of the magnet and the inner parameters. In addition, we realized an experimental middle ear hearing aid system to show the theoretical validity of designed system and this will provide the basis of the development for actually implantable system.

  • PDF

Battery Power Switching System for Implantable Telemetry Systems (체내 삽입 텔리메터리 시스템용 전원 스위칭 시스템 개발)

  • Seo, Hee-Don
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.118-121
    • /
    • 1990
  • This paper describes development of an implantable power switching system for biotelemetry system. This system is designed and manufactured to achieve as small size and low power dissipation as possible, using pulse powered circult and CMOS technology. The function of the power switching system is to connect the implantable battery to implanted sensors and, electronics systems by receiving intermittent command signals from external circuits. The power dissipation of this system was about $15{\mu}W$ for a stand-by operation.

  • PDF

A Case of CRPS Treated with Implantable Port System -A case report- (Implantable Port System을 이용한 복합부위통증증후군 치험 1예 -증례 보고-)

  • Shin, Sung-Shick;Kim, Tae-Sam;Yang, In-Sook
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.274-277
    • /
    • 1997
  • The complex regional pain syndrome(CRPS) exhibit symptoms such as: abnormal skin color, temperature change, abnormal pseudomotor activity, edema. If CRPS is not treated appropriately at acute stage, then the affected extremity may become a useless, painful appendage. Treatment of CRPS by sympathetic blockade may be achieved by repeated intravenous regional guanethidine blocks, repeated anesthetic sympathetic blocks, surgical sympathectomy or oral sympatholytic therapy. We treated 29-year-old male patient with CRPS of left upper extremity by continuous cervical epidural blockade. Due to wound infection and dislocation of the epidural catheter, we inserted an implantable port system to inject the mixture of local anesthetics and small amount of morphine. After 10 months of treatment, patient was cured of symptoms and signs of CRPS and was able to resume a normal life.

  • PDF

Development of transcutaneous energy transmission system for implantable total artificial heart (인공심장용 무선에너지 전송 시스템의 개발)

  • 이우철;안재목;이상훈;민병구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.762-767
    • /
    • 1991
  • To make electromechanical total artificial heart implantable inside the body, transcutaneous energy transmission system was designed and simulated by using PSPICE program. The fabricated system was evaluated by using Mock circulation system and showed comparable performance with the D.C power supply

  • PDF

Development and Evaluation of a Novel Electro-mechanical Implantable Ventricular Assist System (전기-기계식 이식형 좌심실 보조 시스템의 개발 및 평가)

  • 조한상;김원곤;이원용;곽승민;김삼성;김재기;김준택;류문호;류은숙
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.349-358
    • /
    • 2001
  • A novel electro-mechanical implantable ventricular assist system is developed as a bridge to transplantation or recovery for patients with end-stage heart failure. The developed system is composed of an implanted blood pump, an external monitoring system which stores data, and a wearable system including a portable external driver and a portable power supply system. The blood pump is designed to be implanted into the left upper abdominal space and provides blood flow from the left ventricular apex to the aorta. The pulsatile blood flow is generated by a double cylindrical cam. There was mo excessive heat emission from the blood pump into the temperature-controlled chamber in the heat test and no stagnated flow within the blood sac by the observation in the flow visualization test. Animal experiments were performed using sheep and calves. The maximum assist flow rate reached 7.85L/min in the animal experiment. The evaluation results showed that the developed system was feasible for the implantable ventricular assist system. The long-term in vitro durability test and mid-term in vivo experiments are in progress and mow the modified next model is under development.

  • PDF

Development of a wireless telemetry system based on MICS standard (MICS 표준에 기반한 무선 텔레메트리 시스템 개발)

  • Lee, Seung-Ha;Park, Il-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

Development of a transcutaneous system for implantable bio-signal measurement (생체신호계측을 위한 체내 이식형 무선송수신 시스템 개발)

  • Lee, Seung-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2008
  • In order to measure bio-signals, it is desirable to build a fully implantable system which connects directly to neural pathways or body tissue. A design scheme for fully implementable measurement system is proposed in this paper. Consisting of an implanted module and an external system, the proposed scheme delivers power and data between the two modules. The external module sends power via inductive link using a simple H-bridge type oscillator. Also, the implanted module sends measured data to the external system utilizing R/F communication technique at a frequency of ISM band. A stable communication and operation is achieved as the two types of channels are separated. Implemented in a compact size enough to be implanted in human body, the system exhibits good performance in experimental studies.

Implantable Drug Delivery Systems-Design Process

  • Vincent, Croquet;Benolt, Raucent;Onori, Mauro
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.4
    • /
    • pp.40-46
    • /
    • 2006
  • The market of programmable implantable pumps has bound to a monopolistic situation, inducing high device costs, thus making them inaccessible to most patients. Micro-mechanical and medical innovations allow improved performances by reducing the dimensions. This affects the consumption and weight, and, by reducing the number of parts, the cost is also affected. This paper presents the procedure followed to design an innovative implantable drug delivery system. This drug delivery system consists of a low flow pump which shall be implanted in the human body to relieve pain. In comparison to classical known solutions, this pump presents many advantages of high interest in both medical and mechanical terms. The first section of the article describes the specifications which would characterize a perfect delivery system from every points of view. This concerns shape, medication, flow, autonomy, biocompatibility, security and sterilization ability. Afterwards, an overview of existing systems is proposed in a decisional tree. Positive displacement motorized pumps are classified into three main groups: the continuous movement group, the fractioned translation group and the alternative movement group. These systems are described and the different problems which are specific to these mechanisms are presented. Since none of them fully satisfy the specifications, an innovation is justified.. The decisional tree is therefore extended by adding new principles: fractioned refilling and fractioned injection within the fractioned translation movement group, spider guiding system within the alternative translation movement group, rotational bearing guided device and notch hinge guided device in the alternative rotation movement group.

Current Development in Bio-implantable Sensors

  • Swarup, Biswas;Yongju, Lee;Hyojeong, Choi;Hyeok, Kim
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.403-410
    • /
    • 2022
  • Flexible and wearable sensing technologies have emerged as a result of developments in interdisciplinary research across several fields, bringing together various subjects such as biology, physics, chemistry, and information technology. Moreover, various types of flexible wearable biocompatible devices, such customized medical equipment, soft robotics, bio-batteries, and electronic skin patches, have been developed over the last several years that are extensively employed to monitor biological signals. As a result, we present an updated overview of new bio-implantable sensor technologies for various applications and a brief review of the state-of-the-art technologies.