• Title/Summary/Keyword: Implantable Cardioverter Defibrillator

Search Result 21, Processing Time 0.026 seconds

Meta-analysis on risk stratification of malignant ventricular tachyarrhythmic events in arrhythmogenic right ventricular cardiomyopathy

  • Roh, Young-Eun;Jang, Hyun Ji;Cho, Min-Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.2
    • /
    • pp.208-215
    • /
    • 2017
  • Background: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a cardiomyopathy characterized by predominant right ventricular fibro-fatty replacement, right ventricular dysfunction and ventricular arrhythmias. It is a rare but important cause of sudden cardiac death in children and young adults. A meta-analysis on risk stratification of major ventricular tachyarrhythmic events indicating the need for implantable cardioverter defibrillator therapy in ARVC was performed. Methods: The pubmed database was searched from its inception to May 2015. Of the 433 citations identified, 12 were included in this meta-analysis. Data regarding major ventricular tachyarrhythmic events were retrieved in 817 subjects from the studies. For the variables, a combined odds ratio (OR) was calculated using a fixed-effects meta-analysis. Results: Extensive right ventricular dysfunction (OR, 2.44), ventricular late potential (OR, 1.66), inducible ventricular tachyarrhythmia during electrophysiology study (OR, 3.67), non-sustained ventricular tachycardia (OR, 3.78), and history of fatal event/sustained VT (OR, 5.66) identified as significant risk factors (p<0.0001). Conclusion: This meta-analysis shows that extensive right ventricular dysfunction, ventricular late potential, inducible ventricular tachyarrhythmia during electrophysiological study, non-sustained ventricular tachycardia, and history of sustained ventricular tachycardia/fibrillation are consistently reported risk factors of major ventricular tachyarrhythmic events indicating implantable cardioverter defibrillator therapy in patients with ARVC.

Nonpharmacological treatment of arrhythmia (소아 부정맥의 비약물적 치료)

  • Bae, Eun-Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.930-936
    • /
    • 2006
  • Although antiarrhythmic medication has been the main treatment modality for arrhythmia in children, in recent decades technological development and computerization have made great advances in nonpharmacological therapy. This article reviews the transcatheter radiofrequency ablation for tachycardia in children, recent advances of device therapy for bradycardia, antitachycardia pacing, implantable cardioverter defibrillator. As a new field of device therapy, cardiac resynchronization therapy for congestive heart failure is also mentioned.

Effects of Radio Frequency Electromagnetic Fields Emitted by WCDMA Mobile Phones on Pacemakers and ICDs (WCDMA 휴대전화 전자파가 인공심장 박동기 및 이식형 제세동기에 미치는 영향)

  • Chung, Jai Won;Choi, Soo Beom;Park, Jee Soo;Kim, Deok Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.148-154
    • /
    • 2015
  • Reports show that global system for mobile communication (GSM) mobile phones, or two-generation (2G) mobile phones, could affect functions of pacemakers and implantable cardioverter defibrillators (ICDs). In this study, we evaluated the effects of radio frequency electromagnetic fields (RF-EMFs) emitted by wideband code division multiple access (WCDMA) mobile phones, which were third-generation (3G) mobile phones, on pacemakers and ICDs. Five pacemakers and three ICDs were subjected to in-vitro test using a ECG simulator. We used a WCDMA module (average power : 0.25 W, frequency band : 1950 MHz) instead of a real WCDMA mobile phone. To assess the effects of the WCDMA module on pacemakers and ICDs, each implantable device was placed in close proximity (within 3 mm) to the WCDMA module for 5 min. As a result, no effects were observed on the five pacemakers and three ICDs for the RF-EMFs emitted by the WCDMA module. Because WCDMA mobile phones have the higher frequency band (1800-2200 MHz) and lower power output (0.01-0.25 W) than GSM moboile phone, the RF-EMFs emitted by WCDMA mobile phones do not affect patients with pacemaker or ICD.

Efficiency of MVP ECG Risk Score for Prediction of Long-Term Atrial Fibrillation in Patients With ICD for Heart Failure With Reduced Ejection Fraction

  • Levent Pay;Ahmet Cagdas Yumurtas;Ozan Tezen;Tugba Cetin;Semih Eren;Goksel Cinier;Mert Ilker Hayiroglu;Ahmet Ilker Tekkesin
    • Korean Circulation Journal
    • /
    • v.53 no.9
    • /
    • pp.621-631
    • /
    • 2023
  • Background and Objectives: The morphology-voltage-P-wave duration (MVP) electrocardiography (ECG) risk score is a newly defined scoring system that has recently been used for atrial fibrillation (AF) prediction. The aim of this study was to evaluate the ability of the MVP ECG risk score to predict AF in patients with an implantable cardioverter defibrillator (ICD) and heart failure with reduced ejection fraction in long-term follow-up. Methods: The study used a single-center, and retrospective design. The study included 328 patients who underwent ICD implantation in our hospital between January 2010 and April 2021, diagnosed with heart failure. The patients were divided into low, intermediate and high-risk categories according to the MVP ECG risk scores. The long-term development of atrial fibrillation was compared among these 3 groups. Results: The low-risk group included 191 patients, the intermediate-risk group 114 patients, and the high-risk group 23 patients. The long-term AF development rate was 12.0% in the low-risk group, 21.9% in the intermediate risk group, and 78.3% in the high-risk group. Patients in the high-risk group were found to have 5.2 times higher rates of long-term AF occurrence compared to low-risk group. Conclusions: The MVP ECG risk score, which is an inexpensive, simple and easily accessible tool, was found to be a significant predictor of the development of AF in the long-term follow-up of patients with an ICD with heart failure with reduced ejection fraction. This risk score may be used to identify patients who require close follow-up for development and management of AF.

Detection of atrial tachycardia and fibrillation using spectrum analysis of intracardiac signal (Intracardiac Signal의 스펙트럼 분석을 통한 Atrium Tachycardia 및 Fibrillation 검출)

  • Shin, Hang-Sik;Lee, Chung-Keun;Kim, Jin-Kwon;Joo, Young-Min;Lee, Myoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.29-31
    • /
    • 2005
  • Detection methods for atrial tachycardia and fibrillation on the time axis have the advantages of light operational load and are easy to apply to various applications. Despite these advantages, arrhythmia detection algorithm on the time axis cannot stand much noise such as motion artifacts, moreover the peak detection algorithm has high complexity. In this paper, we use a spectrum analysis method for the detection of atrial tachycardia and fibrillation. By applying spectrum analysis and digital filtering on obtained electrogram signals, we can diagnose heart arrhythmia without using peak detection algorithm.

  • PDF

Detection of Atrial Tachycardia and Atrial Fibrillation Using Spectrum Analysis of Intracardiac Signal (Intracardiac Signal의 스펙트럼 분석을 통한 Atrial Tachycardia 및 Atrial Fibrillation 검출)

  • Lee, Chung-Keun;Joung, Bo-Young;Lee, Myoung-Ho;Shin, Hang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.3
    • /
    • pp.142-145
    • /
    • 2006
  • Detection methods for atrial tachycardia and atrial fibrillation on the time axis have the advantages of light operational load and are easy to apply to various applications. Despite these advantages, arrhythmia detection algorithm on the time axis cannot stand much noise such as motion artifacts, moreover the peak detection algorithm has high complexity. In this paper, we use a spectrum analysis method for the detection of atrial tachycardia and atrial fibrillation. By applying spectrum analysis and digital filtering on obtained electrogram signals, we can diagnose heart arrhythmia without using peak detection algorithm.

Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

  • Jin, Bo Kyung;Bang, Ji Seok;Choi, Eun Young;Kim, Gi Beom;Kwon, Bo Sang;Bae, Eun Jung;Noh, Chung Il;Choi, Jung Yun;Kim, Woong Han
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.3
    • /
    • pp.125-129
    • /
    • 2013
  • Purpose: The use of implantable cardioverter defibrillators (ICDs) to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was $14.5{\pm}5.4$ years (range, 2 to 22 years). The follow-up duration was $28.9{\pm}20.4$ months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1), cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years). Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia. During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

Deep Learning-Based Algorithm for the Detection and Characterization of MRI Safety of Cardiac Implantable Electronic Devices on Chest Radiographs

  • Ue-Hwan Kim;Moon Young Kim;Eun-Ah Park;Whal Lee;Woo-Hyun Lim;Hack-Lyoung Kim;Sohee Oh;Kwang Nam Jin
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1918-1928
    • /
    • 2021
  • Objective: With the recent development of various MRI-conditional cardiac implantable electronic devices (CIEDs), the accurate identification and characterization of CIEDs have become critical when performing MRI in patients with CIEDs. We aimed to develop and evaluate a deep learning-based algorithm (DLA) that performs the detection and characterization of parameters, including MRI safety, of CIEDs on chest radiograph (CR) in a single step and compare its performance with other related algorithms that were recently developed. Materials and Methods: We developed a DLA (X-ray CIED identification [XCID]) using 9912 CRs of 958 patients with 968 CIEDs comprising 26 model groups from 4 manufacturers obtained between 2014 and 2019 from one hospital. The performance of XCID was tested with an external dataset consisting of 2122 CRs obtained from a different hospital and compared with the performance of two other related algorithms recently reported, including PacemakerID (PID) and Pacemaker identification with neural networks (PPMnn). Results: The overall accuracies of XCID for the manufacturer classification, model group identification, and MRI safety characterization using the internal test dataset were 99.7% (992/995), 97.2% (967/995), and 98.9% (984/995), respectively. These were 95.8% (2033/2122), 85.4% (1813/2122), and 92.2% (1956/2122), respectively, with the external test dataset. In the comparative study, the accuracy for the manufacturer classification was 95.0% (152/160) for XCID and 91.3% for PPMnn (146/160), which was significantly higher than that for PID (80.0%,128/160; p < 0.001 for both). XCID demonstrated a higher accuracy (88.1%; 141/160) than PPMnn (80.0%; 128/160) in identifying model groups (p < 0.001). Conclusion: The remarkable and consistent performance of XCID suggests its applicability for detection, manufacturer and model identification, as well as MRI safety characterization of CIED on CRs. Further studies are warranted to guarantee the safe use of XCID in clinical practice.

Left Atrial Strain Derived From Cardiac Magnetic Resonance Imaging Can Predict Outcomes of Patients With Acute Myocarditis

  • Jimin Lee;Ki Seok Choo;Yeon Joo Jeong;Geewon Lee;Minhee Hwang;Maria Roselle Abraham;Ji Won Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.512-521
    • /
    • 2023
  • Objective: There is increasing recognition that left atrial (LA) strain can be a prognostic marker of various cardiac diseases. However, its prognostic value in acute myocarditis remains unclear. Therefore, this study aimed to evaluate whether cardiovascular magnetic resonance (CMR)-derived parameters of LA strain can predict outcomes in patients with acute myocarditis. Materials and Methods: We retrospectively analyzed the data of 47 consecutive patients (44.2 ± 18.3 years; 29 males) with acute myocarditis who underwent CMR in 13.5 ± 9.7 days (range, 0-31 days) of symptom onset. Various parameters, including feature-tracked CMR-derived LA strain, were measured using CMR. The composite endpoints included cardiac death, heart transplantation, implantable cardioverter-defibrillator or pacemaker implantation, rehospitalization following a cardiac event, atrial fibrillation, or embolic stroke. The Cox regression analysis was performed to identify associations between the variables derived from CMR and the composite endpoints. Results: After a median follow-up of 37 months, 20 of the 47 (42.6%) patients experienced the composite events. In the multivariable Cox regression analysis, LA reservoir and conduit strains were independent predictors of the composite endpoints, with an adjusted hazard ratio per 1% increase of 0.90 (95% confidence interval [CI], 0.84-0.96; P = 0.002) and 0.91 (95% CI, 0.84-0.98; P = 0.013), respectively. Conclusion: LA reservoir and conduit strains derived from CMR are independent predictors of adverse clinical outcomes in patients with acute myocarditis.

The Extent of Late Gadolinium Enhancement Can Predict Adverse Cardiac Outcomes in Patients with Non-Ischemic Cardiomyopathy with Reduced Left Ventricular Ejection Fraction: A Prospective Observational Study

  • Eun Kyoung Kim;Ga Yeon Lee;Shin Yi Jang;Sung-A Chang;Sung Mok Kim;Sung-Ji Park;Jin-Oh Choi;Seung Woo Park;Yeon Hyeon Choe;Sang-Chol Lee;Jae K. Oh
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.324-333
    • /
    • 2021
  • Objective: The clinical course of an individual patient with heart failure is unpredictable with left ventricle ejection fraction (LVEF) only. We aimed to evaluate the prognostic value of cardiac magnetic resonance (CMR)-derived myocardial fibrosis extent and to determine the cutoff value for event-free survival in patients with non-ischemic cardiomyopathy (NICM) who had severely reduced LVEF. Materials and Methods: Our prospective cohort study included 78 NICM patients with significantly reduced LV systolic function (LVEF < 35%). CMR images were analyzed for the presence and extent of late gadolinium enhancement (LGE). The primary outcome was major adverse cardiac events (MACEs), defined as a composite of cardiac death, heart transplantation, implantable cardioverter-defibrillator discharge for major arrhythmia, and hospitalization for congestive heart failure within 5 years after enrollment. Results: A total of 80.8% (n = 63) of enrolled patients had LGE, with the median LVEF of 25.4% (19.8-32.4%). The extent of myocardial scarring was significantly higher in patients who experienced MACE than in those without any cardiac events (22.0 [5.5-46.1] %LV vs. 6.7 [0-17.1] %LV, respectively, p = 0.008). During follow-up, 51.4% of patients with LGE ≥ 12.0 %LV experienced MACE, along with 20.9% of those with LGE ≤ 12.0 %LV (log-rank p = 0.001). According to multivariate analysis, LGE extent more than 12.0 %LV was independently associated with MACE (adjusted hazard ratio, 6.71; 95% confidence interval, 2.54-17.74; p < 0.001). Conclusion: In NICM patients with significantly reduced LV systolic function, the extent of LGE is a strong predictor for long-term adverse cardiac outcomes. Event-free survival was well discriminated with an LGE cutoff value of 12.0 %LV in these patients.