• 제목/요약/키워드: Implant-supported prosthesis

검색결과 197건 처리시간 0.024초

도재치은 보철법에 의한 심미적 임프란트 상부구조의 제작 (The Esthetic Gingival Porcelain Restoration as Implant-Supported Fixed Prosthesis)

  • 이성복;이경호
    • 대한심미치과학회지
    • /
    • 제10권1호
    • /
    • pp.104-113
    • /
    • 2001
  • This article described a procedure for fabricating an esthetic gingival porcelain restoration as an implant-supported fixed prosthesis for edentulous maxilla. Alternative treatments for fully edentulous patients include an implant-supported overdenture or a fixed implant-supported prosthesis with bilateral distal cantilevers. But, from a functional and biomechanical point of view, the fixed implant-supported prosthesis with posterior cantilevers or implant-supported tissue-borne overdenture do not significantly improve masticatory effectiveness compared with a distributed implant restoration as a fixed implant-supported prosthesis. The fact that the prosthesis is supported by distributed implants over eight for edentulous maxilla in general, provides increased masticatory efficiency as a fixed restoration and similar gingival appearance with esthetic gingival porcelain. It is also detachable by dentist to allow easier after-care of soft tissue and the prosthesis.

  • PDF

임플란트 지지 고정성 치과 보철물 유지방식에 따른 고정체의 직경과 길이 분포 비교 연구 (A comparative study of the distribution of implant fixtures according to length and diameter by retained type of implant-supported fixed prosthesis)

  • 김욱태
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.347-353
    • /
    • 2006
  • The Purpose of this study was to compare the distribution of implant fixtures according to length and diameter between screw-retained and cement-retained implant-supported fixed prosthesis and to asses whether prosthesis retained types affected the selection of size of implant fixtures. This study presents a follow-up 2,416 implant-supported fixed type prosthesis that have been screw retained or cemented retained for about 10 years in 14 dental clinics. Included in the study were 458 men and 397 women and implant fixtures used in this study were screw retained type 1,057 and 1,359 of cemented retained type. The statistical results among the diameter types of fixture by prosthesis retained type was no significant difference noted (P= 0.809) and there was significant differences was enough to among the lengths of fixture by prosthesis retained type (P= 0.020). However there were no significant difference among the fixture diameter types and length by prosthesis retained type (P= 0.486). So there was not affected to prostheis fixation mechanism for the size of implant fixtures.

  • PDF

$Periotest^{(R)}$를 이용한 임프란트지지 보철물의 적합도 평가에 관한 연구 (AN EVALUATION OF PRECISION FIT OF IMPLANT-SUPPORTED PROSTHESIS USING THE PERIOTEST)

  • 김영민;배정식
    • 대한치과보철학회지
    • /
    • 제36권4호
    • /
    • pp.587-597
    • /
    • 1998
  • In this study, the Periotest value was measured with Periotest to evaluate precision fit of the 2-unit and 3-unit implant-supported prosthesis by modifying the size and location of ill-fitted conditions. The 2-unit prosthesis was fabricated with the right implant fitted incorrectly and the 3-unit prosthesis with the right and center implant fitted incorrectly. To evaluate the effects of the ill-fitted sizes, 4 groups were divided.:The control group being the accurately fabricated sample group fitted properly. Group 1 was constructed with $40{\mu}m$ ill-fitted conditions, group 2 with $70{\mu}m$ and group 3 with $100{\mu}m$ ill-fitted conditions. The Periotest value was measured at each implant site after tightening 10Ncm. The result was follows : 1. The PTV on the ill-fitted area in the 2-unit implant-supported prosthesis increased as the ill-fitted conditions increased. There was a statistically significant difference among groups(p<0.05). In the same ill-fitted sample, the PTV depending on the measured location demonstrated a statistically significant difference (p<0.05) 2. The PTV on the ill-fitted area of the 3-unit implant-supported with an ill-fitted condition in the right implant increased as the ill-fitted conditions increased. There was a significant difference among groups (p<0.05). In the same ill-fitted sample, the PTV depending on the measured location demonstrated a statistically significant difference (p<0.05). 3. In the 3-unit implant-supported prosthesis with ill fitting conditions in the center implant, the PTV on the ill-fitted area demonstrated a statistically significant difference between the control group, group 1 and group 2 (p<0.05). In the same ill-fitted sample, the PTV depending on the measured location demonstrated significant difference between the gap side and the adjacent side with over $70{\mu}m$ ill-fitted conditions (p<0.05). The results suggest that Periotest is a valuable objective method for evaluating the precision fit of an implant superstructure.

  • PDF

Maxillary cement retained implant supported monolithic zirconia prosthesis in a full mouth rehabilitation: a clinical report

  • Sadid-Zadeh, Ramtin;Liu, Perng-Ru;Aponte-Wesson, Ruth;O'Neal, Sandra J.
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.209-217
    • /
    • 2013
  • This clinical report presents the reconstruction of a maxillary arch with a cement retained implant supported fixed prosthesis using a monolithic zirconia generated by CAD/CAM system on eight osseointegrated implants. The prosthesis was copy milled from an interim prosthesis minimizing occlusal adjustments on the definitive prosthesis at the time of delivery. Monolithic zirconia provides high esthetics and reduces the number of metal alloys used in the oral cavity.

Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

  • Kim, Seok-Gyu;Chung, Chae-Heon;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.207-213
    • /
    • 2015
  • PURPOSE. The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS. Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and non-cemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS. There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION. Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.

치조골 흡수가 심한 상악 완전 무치악 환자에서 임플란트 고정성 보철물을 이용한 수복 증례 (Implant supported fixed prosthesis for complete edentulous maxilla with severe alveolar ridge resorption: A case report)

  • 최윤지;이지현;진민주
    • 대한치과보철학회지
    • /
    • 제54권2호
    • /
    • pp.152-159
    • /
    • 2016
  • 상악무치악 환자에서 임플란트를 이용한 고정성 보철 수복 치료는 전통적인 가철성 의치에 비해 안정성과 유지력이 개선되어 저작, 발음 등의 기능적인 면과 환자의 심리적 안정성 및 만족도에서 이점을 갖는다. 본 증례에서 환자는 치주질환에 이환된 국소의치의 지대치를 모두 발거한 상악무치악 상태로, 7개의 임플란트를 식립하여 임플란트 지지 고정성 보철물로 수복하였다. 잔존 치조골의 흡수가 심한 전치부 골 결손부위에는 적절한 상순 지지를 얻기 위해 부피가 큰 지르코니아 하부구조물을 제작하였고, 치경부에 분홍색 도재를 축성하여 치은 연조직의 색조 및 외형을 재현하였다. 치료 후 9개월간의 임상 관찰에서 환자는 심미적, 기능적으로 만족하였고, 보철물은 합병증 없이 안정적으로 유지되었기에 이에 보고하고자 한다.

임프란트 지지 국소의치의 임상적 연구 (Clinical study of implant supported removable partial dentures)

  • 박원희
    • 대한치과의사협회지
    • /
    • 제47권4호
    • /
    • pp.184-190
    • /
    • 2009
  • OBJECTIVE The purpose of clinical study was to evaluate the survival of dental implants used in restoring patients with implant supported removable partial dentures (ISRPDs) of different configurations. MATERIALS AND METHODS The sample consisted of 20 consecutively treated partially edentulous patients, who, between 2003 and 2008, had a total of 84implants placed in different arch sites and who were treated with ISRPDs. The mean age was 57 years. Mean follow up time from delivery of ISRPDs was 3 years 2 months (range, 1 to 6 years). Osseointegration failure, postoperative complication of dental prosthesis, and the success rate of ISRPDs were retrospectively evaluated using clinical and radiographic examination. RESULT The overall implant survival rate was 100%. During follow up, the one clasp of removable partial denture was broken in 1 year11 months after prosthesis delivery. All patients were satisfied with their prosthesis. CONCLUSIONS Implant supported removable partial dentures could serve as favorable prognosis. Careful patient selection, with an appropriate maintenance and recall system, is recommended to obtain satisfactory results.

  • PDF

고정성 임플란트 보철물을 이용한 완전 무치악 환자의 구강회복 증례 (Full mouth rehabilitation of edentulous patient with fixed implant prosthesis)

  • 신희현;김종진;백진;차현석;이주희
    • 구강회복응용과학지
    • /
    • 제37권3호
    • /
    • pp.147-156
    • /
    • 2021
  • 완전 무치악 환자의 구강 회복은 통상적 총의치, 하이브리드 보철물, 임플란트 지지 고정성 보철물 등 다양한 치료 옵션을 통해 이루어질 수 있다. 전악 임플란트 고정성 보철 수복의 경우 가철성 수복과 비교해 최종적인 보철물의 형태를 고려하여 정확한 위치에 임플란트를 식립해야 한다는 어려움이 따른다. 본 증례에서는 치아우식과 만성 치주염으로 전악 발거를 요하는 환자의 전악 임플란트 고정성 수복을 진행하였다. 임플란트 식립 단계에서 최종 보철물 형태를 고려하여 제작된 수술용 가이드를 이용하여 원하는 위치에 임플란트를 식립 하였으며 고정성 임시 수복물 단계에서 수정 및 재제작을 통해 기능과 심미를 평가하였다. 이렇게 제작된 임시 수복물을 바탕으로 금속 도재관의 최종 수복물을 장착하였다. 나사 풀림 및 도재 파절 등의 합병증에 대처하기 위해 구치부의 경우 나사 유지형 보철물, 전치부는 나사 시멘트 유지형 보철물로 제작하였다. 그 결과 환자는 최종 보철물 장착 후 기능적 심미적 측면에서 개선된 예후를 보였다.

Trend analysis of prosthodontic treatment modality between 2005 and 2008 in Seoul National University Dental Hospital

  • Li, Hongbo;Lee, Jai-Bong;Liu, Hongchen;Han, Jung-Suk;Yang, Jae-Ho;Koak, Jai-Young;Heo, Seong-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권1호
    • /
    • pp.4-6
    • /
    • 2010
  • PURPOSE. The aim of this article is to analyze the preference for treatment modality of dentists. MATERIAL AND METHODS. Data of 20,038 patients was involved. Data analysis were done by distribution according to the various kinds of prosthesis, including complete denture, removable partial denture, fixed partial denture, implant-supported dental prosthesis as well as distribution according to the professional titles of the dentists finishing the treatment, including resident and professors. RESULTS. The number of cases of dental prosthesis increased year by year. 61.06% of the patients accepted fixed partial denture restoration. The number of patients who accepted implant supported restoration is also increasing year by year. The number of complete denture, implant-supported dental prosthesis finished by professors was larger than that done by residents, while it was contrary for removable partial denture, fixed partial denture, and the difference was statistically significant (P < .05). CONCLUSION. Professors and residents have some difference in the categorization of prosthesis finished. Fixed partial denture and implant-supported dental prosthesis are preferred.

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.