• 제목/요약/키워드: Implant-supported fixed prostheses

검색결과 89건 처리시간 0.018초

Comparative clinical study of the marginal discrepancy of fixed dental prosthesis fabricated by the milling-sintering method using a presintered alloy

  • Kim, Mijoo;Kim, Jaewon;Mai, Hang-Nga;Kwon, Tae-Yub;Choi, Yong-Do;Lee, Cheong-Hee;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.280-285
    • /
    • 2019
  • PURPOSE. The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS. Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (${\alpha}=.05$). RESULTS. Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION. The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.

골격성 III급 부정교합을 가진 환자에서 임플란트 지지 고정성 보철을 이용한 구강회복 증례 (A case of oral rehabilitation using implant fixed prosthesis (skeletal class III malocclusion patient))

  • 강민정;선민지;문홍석;김종은
    • 대한치과보철학회지
    • /
    • 제61권2호
    • /
    • pp.125-134
    • /
    • 2023
  • 골격성 3급 부정교합은 중심위 간섭이 없다면 매우 안정적인 교합 양식이다. 또한 특징적으로 전방 유도가 없고 전치부 반대교합이 동반될 경우 적절한 교합접촉이 없을 수도 있다. 이러한 환자에서 다양한 원인으로 다수 치아를 상실하여 광범위한 구강 회복을 필요로 하는 경우, 환자의 교합관계, 안모의 변화, 측두하악관절의 평가 등 정확한 진단과 면밀한 분석이 필수적이다. 환자의 주소에 따라 심미적 개선을 위해서는 악교정 수술이 동반되는 경우가 많으나 사정 상 불가능한 경우, 최소한의 수직고경 거상을 통해 부분적으로 심미적 개선이 달성될 수 있다. 측두하악관절 장애, 비기능적 악습관 발생, 저작근의 긴장 등 예기치 못한 문제가 발생할 수 있기에 본 환자에서는 가역적인 임시 가철성 의치를 통해 적응 가능 여부를 확인하였으며, 이후 고정성 임시 보철물을 통해 악관절 및 저작근의 적응 여부를 면밀히 관찰하였다. 이후 단계적 치료과정을 통해 상악 전악 임플란트 지지 고정성 보철물과 하악 고정성 보철물을 통해 안정적인 구치부 지지를 얻고 상악 전치부 심미의 부분적 개선을 이루었기에 본 결과를 보고하고자 한다.

전치부 임플란트 보철을 이용한 후방연장 국소의치 수복 (Distal-Extension Removable Partial Denture with Anterior Implant Prostheses: Case Report)

  • 나현준;강동완;손미경
    • 구강회복응용과학지
    • /
    • 제27권4호
    • /
    • pp.437-447
    • /
    • 2011
  • 오랜 기간 국소의치를 장착한 부분 무치악 환자에서, 치아가 결손된 부위는 점진적인 치조골의 흡수가 발생되는 반면, 잔존 지대치 부위는 치조골이 유지되어 있는 것을 볼 수 있다. 이는 차후 잔존 지대치를 상실한 후에도 치아 상실의 시점에 따라 수직적인 골 높이의 현저한 차이를 나타낸다. 이와 같이 전체 치아 발거 후 상하악 악간 거리가 좌우측 또는 전후방으로 다르게 나타나는 환자에서 임플란트를 이용한 고정성 보철물이나 임플란트 피개의치의 제작 시 여러 가지 보철적 문제가 야기될 수 있다. 본 논문은 구치부 결손으로 인해 오랫동안 국소의치를 사용했던 환자에서 치아 상실 후 잔존 치조골의 높이를 고려하여 임플란트 지지 국소의치를 제작한 증례로서 잔존 치조골 량이 많아 악간거리가 짧은 전치부는 임플란트를 식립하여 고정성 보철물로, 오랫동안 치조골의 흡수로 인해 악간거리가 긴 구치부는 국소의치로 수복하였다. 본 증례에서의 임플란트 지지 국소의치는 부가적인 수술이 없이 소수의 임플란트를 식립하고 환자에게 기존 보철물의 양식과 유사한 보철물을 제공함으로서 경제적이고 편안한 치료결과를 보여주었다.

디지털 임플란트 플래닝을 통한 최소침습 보철수복 증례 (Prosthetic rehabilitation with digital implant planning for a minimally invasive surgery approach)

  • 정아름;이영후;홍성진;백장현;노관태;배아란;김형섭;권긍록
    • 대한치과보철학회지
    • /
    • 제60권3호
    • /
    • pp.283-292
    • /
    • 2022
  • 임플란트를 이용한 고정성 보철 치료를 위해서는 보철 치료에 적합한 위치에 임플란트가 식립되어야 하며 이를 위해 guided implant surgery와 CAD-CAM을 활용한 보철물 제작이 최근 널리 사용되고 있다. 수술 시에는 surgical guide를 이용해 flapless 방식으로 최소침습 보철수복이 가능 하다. 본 증례의 환자는 86세 남성 환자로 기존 의치 사용 시 불편함으로 치료를 원하였다. 환자는 전신질환으로 인해 가철성 국소의치 사용이 어려워 상악은 총의치, 하악의 경우 임플란트 고정성 보철물 수복하였다. 전신질환으로 인해 높은 출혈 위험성을 가지므로 surgical guide를 사용해 flapless 방식으로 임플란트를 식립하였다. 최종적으로 상악 총의치 및 하악 나사 유지형 지르코니아를 보철물을 제작하였으며, 만족스러운 기능 및 심미 회복을 보였기에 보고하는 바이다.

디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례 (Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report)

  • 정대길;오경철;심준성;박지만
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.397-404
    • /
    • 2019
  • 성공적인 임플란트 치료를 위해서는 식립부위의 골조직 및 연조직 상태(condition)도 중요하지만 식립 위치 또한 매우 중요하다. 잘못된 위치에 식립된 임플란트는 생물학적, 심미적, 기계적 문제점을 야기하게 된다. 올바른 위치에 임플란트를 식립하기 위해서는 최종 보철물을 고려해야 하며 이를 위해서는 진단 왁스업 과정이 필요하다. 발치 후 사용 할 임시 의치의 인공치를 진단 왁스업 형태대로 제작하면 구강내에서 진단 왁스업 형태를 평가해 볼 수 있으며, 잘 적응된 임시 의치를 복제해 제작한 임플란트 수술용 템플릿으로 계획된 위치에 임플란트를 식립하는 것이 가능하다. 본 증례에서는 진단 왁스업을 디지털 복제하여 의치용 인공치를 맞춤형으로 제작하였고, 이를 이용해 임시 의치를 제작하였다. 충분한 적응 기간을 거친 후 임시 의치를 복제하여 임플란트 수술용 템플릿을 제작한 다음, 이를 활용하여 계획된 위치에 임플란트를 식립하였다. 골유착을 위한 충분한 치유기간을 가진 다음 진단 왁스업 형태가 반영된 임플란트 지지형 고정성 보철물을 제작하였다. 최종 보철물 장착 후 6개월간의 경과 관찰 기간 동안 심미적, 기능적으로 만족할 만한 치료 결과를 보였기에 이를 보고하고자 한다.

임플랜트 상부 보철물의 고정 방식에 따른 힘의 분포에 관한 연구 : 나사 유지형 대 시멘트 유지형 (A COMPARISON OF LOAD TRANSFER IN SCREW- AND CEMENT-RETAINED IMPLANT FIXED PARTIAL DENTURE DESIGNS)

  • 이주희;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.125-145
    • /
    • 2001
  • To compare the stress distribution patterns between cement-retained and screw-retained implant supported fixed prostheses according to four different abutment types, a three dimensional finite element analysis was performed. The hypothetical three unit fixed partial denture case was modelled on the three implants(10mm length and 3.75 diameter) in mandibular bone. Four angles of implantation(vertical, 10, 15 and 20 degree inclined mesially) were created and three different directions of force (vertical, oblique, horizontal) were applied at the center of the second premolar and distal end of the first molar for each cases. Within the limits of this study, the results were as follows, 1. In vertically installed cases, the more stress was concentrated at upper components, but mesially inclined cases, the more stress was concentrated at cortical bone. 2, The more inclined mesially the more stress was observed, especially at cortical bone. 3. The cement-retained models showed lower principal stress and more even stress distribution than the screw-retained models. 4. The similar stress distribution pattern was showed in model 1 and model 2, model 3 and model 4. 5. The more stress was observed when the loads were applied at the distal end of 1st molar than the center of 2nd premolar. 6 The fixture and the model as a whole, lesser stress values were observed when vertical loads were applied as compared to horizontal and oblique loads.

  • PDF

Narrow-diameter implants with conical connection for restoring the posterior edentulous region

  • Woo, In-Hee;Kim, Ju-Won;Kang, So-Young;Kim, Young-Hee;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.31.1-31.7
    • /
    • 2016
  • Background: The objective of this retrospective study was to show results from platform-switched narrow-diameter implants in the posterior edentulous region, which we followed up for more than 1 year after functional loading. Methods: Ninety-eight narrow implants were inserted into 66 patients. After healing, fixed implant-supported prostheses were delivered to the patients, and Periotest and radiographic examinations were performed. After the first year of loading, the implant outcome was again evaluated clinically and radiographically using the Periotest analysis. Crestal bone loss and Periotest values (PTVs) were used to evaluate the effect of surgery, prosthesis, implant, and a host-related factor. A general linear model was used to statistically detect variables statistically associated with crestal bone loss and Periotest value. Results: We followed up on the implants over 1 to 4 years after loading; their survival rate was 100 %, and pronounced differences from PTVs were noted among jaw location, bone quality, and loading period. No difference was detected in bone loss among the variables studied. Bone loss after functional loading was $0.14{\pm}0.39mm$. The stability value from the Periotest was $-3.29{\pm}0.50$. Conclusions: Within the limitations of this study, judicious use of platform-switched narrow implants with a conical connection must be considered an alternative for wide-diameter implants to restore a posterior edentulous region.

구강안면 근긴장이상을 가진 완전 무치악 환자에서 구치부 지르코니아 교합면을 갖는 상악 총의치와 하악 임플란트 지지 고정성 보철물의 수복 (Maxillary complete denture with posterior zirconia occlusion and mandibular implant support fixed prostheses in completely edentulous patients with orofacial dystonia)

  • 서종민;정창모;이소현
    • 구강회복응용과학지
    • /
    • 제39권4호
    • /
    • pp.237-249
    • /
    • 2023
  • 구강안면 근긴장이상(Orofacial dystonia)은 자신의 의지와 상관없이 불수의적으로 얼굴, 입술, 혀 및 턱 주변을 불규칙적이거나 반복적으로 움직이는 신경운동학적 장애로 틱장애로 불리기도 한다. 이러한 증상을 갖는 무치악 환자는 총의치 사용의 어려움과 더불어 언어 장애 및 연하곤란, 구강안면의 통증까지 기능적이고 심미적인 문제점들을 겪게 된다. 본 증례에서는 비교적 젊은 나이에 완전 무치악 상태를 경험하게 된 구강안면 근긴장이상 환자를 위해, 양측 구치부 지르코니아 교합면을 갖는 상악 총의치와 하악 임플란트 지지 고정성 보철물의 수복치료를 시행하고 지속적인 미소훈련을 시행하여 안면근육의 심미적인 개선을 도모하고자 하였다. 치료의 결과, 환자는 저작기능과 심미성이 향상된 것 뿐만 아니라, 심리적 안정감을 회복하여 정상적인 일상생활이 가능해진 것에 대해 매우 만족하였기에 이를 보고하고자 한다.

부분 무치악 환자에서 고기능성 폴리머(PEKK) 지대주를 이용한 임플란트 고정성 보철물 수복 증례 (Implant-supported fixed prostheses with high-performance polymer (PEKK) abutments in partial edentulous patients: A case report)

  • 하승룡
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.71-78
    • /
    • 2021
  • 완전무치악 환자한테 처음으로 시도되었던 임플란트 보철치료는 현재는 단일치아 상실된 경우까지 그 활용범위가 넓어졌으며, 임플란트 보철치료는 현대 치과에서는 거의 필수적인 치료방법으로 자리매김 하였다. 임플란트 보철물을 제작하는데 사용되는 재료도 초기에 비해 다양해졌는데, 그 중 하나가 고기능성 폴리머의 적용이다. 예전부터 의과에서 많이 사용되어 왔던 고기능성 폴리머를 치과에서도 시도하는 빈도가 점점 늘어나고 있다. 이에 고기능성 폴리머를 구치부 임플란트 지대주로 사용한 3가지 증례를 보고하고자 한다. 첫번째 증례는 하악 좌측 제2소구치가 상실된 부위에 PEKK 지대주 및 PFG 크라운(시멘트-나사-유지형)을 제작, 장착하였으며, 두번째 증례는 상실된 상악 좌측 제1대구치 부위에 PEKK 지대주 및 monolithic zirconia 크라운(시멘트-나사-유지형)을 제작, 장착하였으며, 마지막 증례는 상악 우측 제1,2 대구치 상실부위에 PEKK 지대주 및 splinted PFM 크라운(시멘트-나사-유지형)을 제작하여 장착하였다. 4년의 추적 관찰 결과 상기 환자 모두 심미적 및 기능적으로 만족스러운 결과를 얻었기에 증례를 보고하고자 한다.

완전 디지털 시스템을 이용한 상악동 거상술 및 구치부 임플란트 고정성 보철 수복 증례 (Sinus floor elevation and implant-supported fixed dental prosthesis in the posterior area, with full-digital system: a case report)

  • 박강수;김선재;표세욱;장재승
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.157-164
    • /
    • 2024
  • 진단, 수술, 인상, 보철물 제작 등 임플란트 치료 전 과정에서 디지털 기술이 활용되고 있다. 본 증례에서는 디지털 수술 가이드를 이용하여 합병증 없이 상악동 거상술을 시행하고, 계획된 위치에 임플란트를 식립하였다. 골유착을 위한 치유 기간 이후, CAD-CAM(Computer-aided design/Computer-aided Manufacturing)으로 맞춤형 지대주 및 임시 보철물을 제작하여 장착하고, 환자의 적응도와 교합을 평가하였다. 임시 보철물상에서 교합 변화가 관찰되어, 광중합형 컴포지트 레진으로 수리하였다. 최종 보철물 제작 시, 지대주의 수직 침하, 임시 보철물의 형태와 적응된 교합 관계를 반영하기 위해, 이중 스캔과 지대주 수준의 디지털 인상을 채득하였다. 치은 압배 없이 치은 연하 변연을 인기하기 위해, CAD-CAM 소프트웨어상에서 라이브러리화된 지대주 데이터를 중첩하고, 지르코니아 최종보철물 제작하여 장착하였다. 구치부 임플란트 수복 시, 디지털 시스템을 이용하여 전통적인 방법에서 겪는 어려움을 줄이고, 수술부터 보철물 제작까지 효율적인 치료 과정과 안정적이고 예지성 있는 결과를 얻어 보고하는 바이다.