• 제목/요약/키워드: Implant supported prosthesis

검색결과 203건 처리시간 0.023초

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례 (Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report)

  • 성현미;설경희;강선우;김정한
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.131-139
    • /
    • 2024
  • 무치악 환자에서 임플란트를 이용한 보철치료는 임플란트 고정성 보철, 임플란트 융합 국소 의치, 하이브리드 보철물, 임플란트 유지 및 지지 피개의치 등의 다양한 방법이 있다. 본 증례에서는 중등도 이상의 만성 치주염에 이환 되어 전악 발치가 필요한 환자에서 computer guided surgery를 이용하여 계획된 위치에 임플란트를 식립하였다. 상악은 불량한 골질로 초기고정력이 충분하지 않아 지연 부하를 시행하였고 골 유착 기간 동안 임시 의치를 사용하였다. 하악은 안정적인 초기 고정을 얻어 즉시 부하를 이용하여 환자의 불편감을 감소시켰다. 임플란트 일차 안정은 즉시 부하를 얻기 위해 가장 중요한 요소로 여겨지기 때문에 수술 전 반드시 임상적, 방사선학적 평가를 통해 잔존 치조골 양 및 골질을 파악해야 한다.

임플란트 지지 나사-시멘트 유지형 보철물에서 보철물-지대주 제거 후 변연부 연마의 효과: 증례보고 (Burnishing effect on marginal misfit of implant-supported screw-and-cement retained prostheses: A case report)

  • 김미주;이두형
    • 대한치과보철학회지
    • /
    • 제58권3호
    • /
    • pp.239-243
    • /
    • 2020
  • 고정성 보철물의 변연 적합도가 낮은 경우 치태침착, 치주질환, 치아과민, 보철물 구성요소 파절, 시멘트 상실 등의 생물학적, 기계적 합병증이 발생할 가능성이 증가할 수 있다. 이러한 합병증은 보철물의 장기간의 성공과 생존에 영향을 미친다. 본 증례는 임플란트 지지 나사-시멘트 유지형 보철물에서 보철물 장착 시 보철물-지대주를 제거하고 변연부를 연마하여 변연간극을 최소화할 수 있는 임상과정을 보여준다. 그리고 변연 간극을 연마 전과 후에 측정하여 비교 관찰하였다. 본 기술은 변연 적합도를 높여 보철물의 수명 연장에 기여할 수 있다.

Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method

  • Tiossi, Rodrigo;Falcao-Filho, Hilmo Barreto Leite;De Aguiar, Fabio Afranio Junior;Rodrigues, Renata Cristina Silveira;De Mattos, Maria da Gloria Chiarello;Ribeiro, Ricardo Faria
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권2호
    • /
    • pp.89-92
    • /
    • 2012
  • PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C ($6.43{\pm}3.24{\mu}m$) when compared to Groups A ($16.50{\pm}7.55{\mu}m$) and B ($16.27{\pm}1.71{\mu}m$) ($P$ <.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, $58.66{\pm}14.30{\mu}m$; Group B, $39.48{\pm}12.03{\mu}m$; Group C, $23.13{\pm}8.24{\mu}m$) ($P$ <.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks.

Computer-guided implant surgery를 활용한 상악 무치악 환자의 전악 임플란트고정성 보철물 수복 증례 (Full mouth implant-supported fixed prosthesis restoration of an edentulous maxillary patient using computer-guided implant surgery)

  • 이민태;김성용;임선영;이용상;이근우;김성아
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.63-72
    • /
    • 2023
  • 완전 무치악에서 전악 임플란트 고정성 수복물로 구강회복 치료를 진행할 경우, 해당 악궁의 해부학적 상황과 대합치와의 관계를 고려하여 최종 보철물의 형태와 위치를 결정하는 과정과 이에 따라 다수의 임플란트를 계획된 방향과 각도로 식립하는 과정은 매우 중요하다. 본 증례는 기존 의치의 불편감으로 내원한 상악 무치악 환자를 computer-guided surgery를 통해 상부 보철물에 기반하여 이상적으로 계획된 위치에 임플란트를 식립하였다. 이를 통해 상악 전악 임플란트 고정성 보철물을 제작하여 구강 회복을 진행한 치료로 환자와 술자 모두 기능 및 심미적으로 만족할만한 결과를 얻었기에 이를 보고하고자 한다.

적합도에 따른 ITI 임플란트 지지 고정성 국소의치의 삼차원 유한요소 분석 (Three Dimensional Finite Element Analysis on ITI Implant Supported Fixed Partial Dentures with Various Fitting Accuracy)

  • 최민호;이일권;김유리;조혜원
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.75-87
    • /
    • 2006
  • The purpose of this study was to investigate the effects of prostheses misfit, cantilever on the stress distribution in the implant components and surrounding bone using three dimensional finite element analysis. Two standard 3-dimensional finite element models were constructed: (1) 3 ITI implant supported, 3-unit fixed partial denture and (2) 3 ITI implant supported, 3-unit fixed partial denture with a distal cantilever. variations of the standard finite element models were made by placing a $100{\mu}m$ or $200{\mu}m$ gap between the fixture, the abutment and the crown on the second premolar and first molar. Total 14 models were constructed. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the distal marginal ridge of the distal molar. von Mises stresses were recorded and compared in the crowns, abutments, crestal compact bones, and trabecular bones. The results were obtained as follows: 1. In the ITI implant system, cement-retained prostheses showed comparatively low stress distributions on all the implant components and fixtures regardless of the misfit sizes under vertical loading. The stresses were increased twice under oblique loading especially in the prostheses with cantilever, but neither showed the effects of misfit size. 2. Under the oblique loading and posterior cantilever, the stresses were highly increased in the crestal bones around ITI implants, but effects of misfit were not shown. Although higher stresses were shown on the apical portion of trabecular bones, the effects by misfit were little and the stresses were increased by the posterior cantilever. 3. When the cement loss happened in the ITI implant supported FPD with misfit, the stresses were increased in the implant componets and supporting structures.

Finite element analysis in static and dynamic behaviors of dental prosthesis

  • Djebbar, N.;Serier, B.;Bouiadjra, B. Bachir
    • Structural Engineering and Mechanics
    • /
    • 제55권1호
    • /
    • pp.65-78
    • /
    • 2015
  • In recent years, implants have gained growing importance in all areas of medicine. The success of the treatment depends on many factors affecting the bone-implant, implant-abutment and abutment-prosthesis interfaces. In this paper, static and dynamic behaviors of the dental prosthesis are investigated. Three-dimensional finite element models of dental prosthesis were constructed. Dynamic loads in 5 sec applied on occlusal surface. Therefore, FEA was selected for use in this study to examine the effect of the static and dynamic loads on the stress distribution for an implant-supported fixed partial denture and supporting bone tissue.

상악의 임플란트 고정성 보철물과 후방연장 국소의치를 이용하여 수복한 10년 경과 관찰 증례 (Maxillary implant-supported fixed prosthesis engaged by distal-extension removable partial denture for 10 years: a case report)

  • 류리;박연희;오원석;이정진;박주미
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.121-127
    • /
    • 2020
  • 상악 무치악 환자에서 치료 방법을 결정하는데 있어 생역학적 고려사항과 함께 전치부 치아에 대한 환자의 심미적 요구도 고려될 수 있다. 이 증례 보고는 전치부의 임플란트 고정성 보철물과 구치부의 후방 연장 가철성 국소의치로 구강 기능이 회복된 상악 무치악 환자의 10년 동안 임상 결과를 기술하고 있다. 상악 전방에 임플란트 고정성 보철물로 4개의 임플란트를 연결고정 하였으며 후방에 가공선 유지장치를 가진 가철성 국소의치가 장착되었다. 하악 무치악은 임플란트 피개의치로 수복되었다. 경과 관찰 기간 동안 고정성 보철물의 인공치아와 전장 레진의 변색, 사고로 인한 보철물 파절 이외에 임플란트 및 국소의치 관련된 기계적, 기계적 생물학적 주요 합병증은 관찰되지 않았다.

Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

  • Yuan, Judy Chia-Chun;Sukotjo, Cortino
    • Journal of Periodontal and Implant Science
    • /
    • 제43권2호
    • /
    • pp.51-57
    • /
    • 2013
  • Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices.

Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity

  • Shah, Farhan Khalid;Gebreel, Ashraf;Elshokouki, Ali Hamed;Habib, Ahmed Ali;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권2호
    • /
    • pp.61-71
    • /
    • 2012
  • PURPOSE. To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS. Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS. Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION. Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis.