• 제목/요약/키워드: Implant stem

검색결과 62건 처리시간 0.034초

FEM을 이용한 cement type hip implant의 Stem 단면형상에 따른 응력분석 (The Stress analysis for a sectional stem shape of cement type hip implant using the finite element method)

  • 박흥석;이문규;전흥재;최귀원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.651-652
    • /
    • 2006
  • The choice of suitable hip implant is one of important factors in total hip replacement (THR). In clinical view points, improper adaptation of hip implant might cause abnormal stress distribution to the bone, which can shorten the lifespan of replaced hip implant. Currently, interest in custom-designed hip implants has increased as studies reveals the importance of geometric shape of patient's femur in modeling and designing custom hip implants. In this study, we have developed the custom-designed hip implant models with various sizes in hip implant, and the stress distribution in the bone was analyzed using Finite Elements methods. It was found that minimizing the gap between implant stem and femoral cavity is crucial to minimize stress concentration in the bone.

  • PDF

인공무릎관절에 있어서 임플란트의 재료 및 고정방법에 따른 응력분석 (Stress Analysis of Total Knee System Depending on Implant Materials and Fixation Methods)

  • 조철형;조용균;최재봉;최귀원
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.484-488
    • /
    • 1997
  • Three-dimensional finite element analyses were used to compare the stress distribution and the stability of the fixation among seven different tibial components and to investigate the effect due to implant materials in total knee arthroplasty. The components included an intact tibia(Type I), Cemented Cobalt-Chromium tibial tray implanted with a PMMA cemented Co-Cr stem(Type II), Cemented Co-Cr tibial tray with a uncemented Co-Cr stem(Type III), Cemented Ultra High Molecular Weight Polyethylene (UHMWPE) tibial tray with a cemented UHMWPE stem (Type IV), Cemented UHMWPE tray with a uncemented UHMWPE stem(Type V), Cemented Co-Cr tray without a stem(Type VI), and Cemented UHMWPE tray without a stem(Type VII). Uncemented components were assumed to have complete bony in growth and a rigid state of fixation between component and bone. The interface between bone/cement/component of cemented components was also assumed to be fully bonded. Bi-condylar forces were applied. The results indicated that Uncemented stem components provided lower bone stress shielding and stress concentration. The UHMWPE tray and stem component showed better agreement with the intact tibia than the Co-Cr Alloy tray and stem components. If the implant tray can be fixed firmed without a stem, Cemented PE tray without a stem(Type VII) may be recommended to give the best characteristics in the sense of stress distribution and stability.

  • PDF

줄기 세포 이식 치료를 통한 의료 산업적 융합효과 (The convergence effect of medical industry through stem cell implant treatment)

  • 이태훈
    • 융합정보논문지
    • /
    • 제8권2호
    • /
    • pp.61-65
    • /
    • 2018
  • 본 연구는 이식된 줄기세포들이 혈관용 클립압박으로 유도된 척수경색 동물들에서 행동학적 결핍을 감소시키는 연구를 진행하였다. 흉수신경 9번과 10번에 척수 손상후 5일후에 배아줄기세포 이식을 통해서 배아줄기세포가 경색부위를 채워지게 되므로 이식후 손상부위의 조직학적 감소와 신경세포군의 조직학적 재생을 증명하는데 중점을 두었다. 본 연구를 통해 마우스 배아줄기세포의 이식이 중증 척수 손상후 행동학적 발달을 보여주는 명백한 결과들을 도출하였음을 보여주고 있다. 이러한 마우스 배아줄기세포는 신경학적 손상에 대한 치료로서 사용될 수 있는 처치법이다. 결론적으로, 줄기세포 적용은 손상조직을 재생시켜서 기능적, 행동적 향상에 기여할 수 있기에 다양한 줄기세포 치료법을 통해 임상적 적용을 위한 중요한 치료법이 될 수 있다.

인공고관절 치환술에서 대퇴주대 회전에 따른 시멘트막 두께 변화 (Change of the Cement Mantle Thickness According to the Movement of the Femoral Stem in THRA)

  • 박용국;김진곤
    • 한국정밀공학회지
    • /
    • 제24권2호
    • /
    • pp.140-148
    • /
    • 2007
  • THRA(Total Hip Replacement Arthroplasty) has been widely used for several decades as a viable treatment of otherwise-unsolved hip problems. In THRA surgery, cement mantle thickness is critical to long-term implant survival of femoral stem fixed with cement. Numerous studies reported thin or incomplete cement mantle causes osteolysis, loosening, and the failure of implant. To analyze the effect of femoral stem rotation on cement thickness, in this study, we select two most popular stems used in THRA. Using CAD models obtained from a 3D scanner, we measure the cement mantle thickness developed by the rotation of a femoral stem in the virtual space created by broaching. The study shows that as the femoral stem deviates from the target coordinates, the minimum thickness of cement decreases. Therefore, we recommend development of a new methodology for accurate insertion of a femoral stem along the broached space. Also, modification of the stem design robust to the unintentional movement of a femoral stem in the broached space, can alleviate the problem.

골육세포 성장 촉진을 위한 스마트 써피스 텍스처링 임플란트 스템 제작 기술 (Smart Surface Texturing Implant Stem for Enhancement of Osteoblast Cell Biocompatibility)

  • 김경한;이제훈;박종권;진석원;최완해;이홍진
    • 한국정밀공학회지
    • /
    • 제31권5호
    • /
    • pp.375-380
    • /
    • 2014
  • To enhance biocompatibility between the orthopedic implant stem and obsteoblast cells, bone-forming cells, micro-size holes are patterned in Ti plate surface. Initially, the house built laser power stabilization system is applied to the laser micro patterning machine to convince repeatable result. Various pulse widths are irradiated Ti plate and relationship between diameters of patterned holes and pulsed width is derived. Effect of multi pulse is observed and optimal pulse number is considered to avoid heat affected zone. After MG-63 osbeoblast cells are cultured, micro patterned Ti plates are compared with control plates. In SEM image, cells are well aligned and aggregation is observed in both 60, and $100{\mu}m$ patterned plates. Finally, free form surface stem model is prepared to test micro hole patterning.

인공무릎관절 전치환술에 있어 축방향 충격에 의한 Tibial Component의 응답 특성 분석 연구 (A Numerical Study on the Response of the Tibial Component in Total Knee Arthroplasty to Longitudinal Impact)

  • 조용균;조철형;최재봉;이태수;최귀원
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권5호
    • /
    • pp.503-511
    • /
    • 1998
  • 본 연구에서는 동적충격하중 하에서 다양한 tibial component system의 하중전달현상 및 발생 가능한 실패기전을 관찰하기 위해 서로 다른 tibial component들에 대한 수치해석을 통한 응력분포를 관찰하고 또한 접합 상태에 따른 임플란트 시스템이 받는 영향을 비교 분석하였다. 따라서, 해석에 고려되는 모델은 정상 경골과 현재 가장 많이 적용되는 시스템인 시멘트형과 무시멘트형 metal-backed tibial component, 폴리에틸렌으로 된 시멘트형 tibial component, 그리고 골과 slew사이의 비접합상태를 가정한 metal-backed tibial component을 포함한다. 해석 결과 metal-backed tibial component의 stem 끝 부분에서는 시멘트형이 무시멘트형 보다 약간 더 놀은 최대 응력을 보였다. 반면, 폴리에틸렌으로 된 tibial component의 경우 stem 글 부분에서의 최대 응력은 metal-backed tibial component에 비해 차 반 정도로 줄었고, 전체적으로 정상 경골에 유사한 응답 특성을 보여주었다. 골과 stem 사이의 비접합을 가정한 경우 금속 tray 밑 부된에서의 응력은 완전히 접합된 경우 보다 3배 더 높았고, stem 끝부분에서는 시간에 따른 불안정한 응력이 관찰되어 이 현상은 임플란트 해리현상과 불완전한 골접합을 가중시키는 원인으로 사료된다. 따라서, 수직충격하중을 고려한 경우 골에 안정하게 고정되는 폴리에틸렌 tibial component가 가장 바람직하다.

  • PDF

Bio-hybrid dental implants prepared using stem cells with β-TCP-coated titanium and zirconia

  • Safi, Ihab Nabeel;Hussein, Basima Mohammed Ali;Al-Shammari, Ahmed Majeed
    • Journal of Periodontal and Implant Science
    • /
    • 제52권3호
    • /
    • pp.242-257
    • /
    • 2022
  • Purpose: This study investigated periodontal ligament (PDL) restoration in osseointegrated implants using stem cells. Methods: Commercial pure titanium and zirconium oxide (zirconia) were coated with beta-tricalcium phosphate (β-TCP) using a long-pulse Nd:YAG laser (1,064 nm). Isolated bone marrow mesenchymal cells (BMMSCs) from rabbit tibia and femur, isolated PDL stem cells (PDLSCs) from the lower right incisor, and co-cultured BMMSCs and PDLSCs were tested for periostin markers using an immunofluorescent assay. Implants with 3D-engineered tissue were implanted into the lower right central incisors after extraction from rabbits. Forty implants (Ti or zirconia) were subdivided according to the duration of implantation (healing period: 45 or 90 days). Each subgroup (20 implants) was subdivided into 4 groups (without cells, PDLSC sheets, BMMSC sheets, and co-culture cell sheets). All groups underwent histological testing involving haematoxylin and eosin staining and immunohistochemistry, stereoscopic analysis to measure the PDL width, and field emission scanning electron microscopy (FESEM). The natural lower central incisors were used as controls. Results: The BMMSCs co-cultured with PDLSCs generated a well-formed PDL tissue that exhibited positive periostin expression. Histological analysis showed that the implantation of coated (Ti and zirconia) dental implants without a cell sheet resulted in a well-osseointegrated implant at both healing intervals, which was confirmed with FESEM analysis and negative periostin expression. The mesenchymal tissue structured from PDLSCs only or co-cultured (BMMSCs and PDLSCs) could form a natural periodontal tissue with no significant difference between Ti and zirconia implants, consequently forming a biohybrid dental implant. Green fluorescence for periostin was clearly detected around the biohybrid implants after 45 and 90 days. FESEM showed the invasion of PDL-like fibres perpendicular to the cementum of the bio-hybrid implants. Conclusions: β-TCP-coated (Ti and zirconia) implants generated periodontal tissue and formed biohybrid implants when mesenchymal-tissue-layered cell sheets were isolated from PDLSCs alone or co-cultured BMMSCs and PDLSCs.

슬관절 재전치환술용 경골 삽입물 형상이 주대 말단부의 접촉압력과 응력 분포에 미치는 영향 (Effect of Stem Design on Contact Pressure and Stress Distribution of End-of-stem in Revision TKR)

  • 김윤혁;권오수;박시몬
    • 한국정밀공학회지
    • /
    • 제23권11호
    • /
    • pp.126-134
    • /
    • 2006
  • In this study, the effect of stem-end design on contact pressure and stress distribution in revision TKR was investigated using finite element method. The finite element model of tibia, including the cortical bone, the cancellous bone and canal, was developed based on CT images. The implant models with various stem lengths, diameters, friction coefficients, and press-fit effects were considered. The results showed that the longer stem length, the stronger press-fit, the bigger stem diameter, and the higher friction coefficient increased both peak contact pressure and Von-Mises stress distributions. The results supported the clinical hypothesis that peak contact pressure and stress are related to the stem end pain. The results of this study will be useful to design the stem and reduce the end-of-stem pain in revision TKR.

스템 길이에 따른 환자맞춤 인공고관절의 역학적 안정성 비교 (Comparison of Biomechanical Stability of Custom-made Hip Implants using Finite Element Analysis)

  • 전용태
    • 한국CDE학회논문집
    • /
    • 제21권4호
    • /
    • pp.426-432
    • /
    • 2016
  • Designing a morphologically well-fitted hip implant to a patient anatomy is desirable to improve surgical outcomes since a commercial ready-made hip implant may not well conform to the patient joint. In this study, biomechanical stability of patient-specific hip implants with two different stem lengths was compared and discussed using a 3D finite element analysis (FEA). The FEA results in this study showed that an increase in stem length brings about more the peaked von-Mises stress (PVMS) in the prosthesis and less in the femur. However the decrease in von-Mises stress in the femur causes stress shielding phenomenon that usually leads to considerable bone resorption. Although, in biomechanical stability point of view, this work recommends the use of smaller stems, the length of stem must be determined by considering both the von-Mises stress and the stress-shielding phenomenon.

당뇨 유도 백서 경골에 매식한 티타늄 임플란트 주위에 지방조직 유래 줄기세포 적용 시 골치유에 미치는 영향 (Effect of adipose-derived stem cells on bone healing on titanium implant in tibia of diabetes mellitus induced rats)

  • 김민구;정인교;신상훈;김철훈;김복주;김정한;황영섭;정유진;김진우;김욱규
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권5호
    • /
    • pp.392-401
    • /
    • 2010
  • Introduction: Diabetes mellitus, as a major health problem for the elderly has been shown to alter the properties of the bone and impair bone healing around a titanium implant in both humans and animals. The aim of this study was to examine the effect of adipose-derived stem cells on the healing process around a titanium implant in streptozotocin-induced diabetic rats. Materials and Methods: Thirteen rats were divided into two groups: adipose-derived stem cells injected group and a control group. A titanium screw implant (diameter: 2.0 mm, length: 3.5 mm) was placed into both tibia of 13 rats: 13 right tibia as the control group and 13 left tibia as the experimental group. The rats were sacrificed at different intervals (1, 2, and 4 weeks) after implantation for histopathology observations and immunohistochemistric analysis. Results: The histopathological findings revealed earlier new formed bone in the experimental group than the control group. In particular, at 1 week after implantation, the experimental group showed more newly formed bone and collagen around the implant than the control group. In immunohistochemistric analysis, osteoprotegerin (OPG) expression in the experimental group increased early compared to that of the control group until 2 weeks after implantation. However, after 2 weeks, OPG expression in the experimental group was similar to OPG expression in the control group. The receptor activator of nuclear factor ${\kappa}B$ ligand (RANKL) expression in the experimental group increased early compared to that of the control group, and then decreased at 2 weeks. After 2 weeks, the level of RANKL expression was similar in both groups. Conclusion: These results suggest that adipose-derived stem cells in implantation can promote bone healing around titanium, particularly in diabetes mellitus induced animals.