• 제목/요약/키워드: Implant prostheses

검색결과 321건 처리시간 0.025초

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권1호
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.

임플란트 지지 고정성 보철물에서 금과 지르코니아의 마모 비교에 대한 임상 연구 (Clinical study on the comparison of gold and zirconia wear in an implant-supported fixed prosthesis)

  • 김지환;양승원;오남식
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.252-259
    • /
    • 2017
  • 목적: 본 연구의 목적은 지르코니아 전장관과 금전장관으로 수복된 임플란트 지지 고정성 보철물의 장착 후 초기 6개월간의 마모를 비교 분석하는 것이다. 연구 재료 및 방법: 2015년 1월부터 2016년 1월까지, 대구치 부위에 임플란트 지지 고정성 보철 수복을 요하는 환자를 대상으로 하였다. 총 47개에 대하여 임플란트 지지 고정성 보철물과 대합치에 대해 조사를 시행하였으며, 보철물 장착 1주 및 6개월 후 보철물 및 대합치를 인상채득 하여 교합면의 형태를 인기 하였다. 인상체를 스캔하여 보철물 및 대합치의 교합면 형태를 비교하여 마모 분석을 시행하였다. SPSS (Version 23.0; SPSS, IBM Corporation, Armonk, USA) 프로그램을 이용하여 정규성 분석 후 Mann-Whitney 분석을 시행하였다. 결과: 임플란트 지지 고정성 보철물에서 지르코니아 전장관과 금전장관 보철물의 6개월간 평균 수직거리 차의 중앙값은 각각 $50.84{\mu}m$, $42.84{\mu}m$로 통계적 유의차가 없었다(P > 0.05). 대합치가 자연치인 경우, 지르코니아 전장관 및 금전장관 보철물의 6개월간 평균 수직거리 차의 중앙값은 각각 $47.72{\mu}m$, $41.97{\mu}m$였으며, 대합치 법랑질의 평균 수직거리 차의 중앙값은 각각 $47.26{\mu}m$, $44.59{\mu}m$이었고, 통계적 유의차는 없었다(P > 0.05). 결론: 조사 기간이 짧았고, 실험군의 개수가 적었다는 단점이 있지만, 임플란트 지지 고정성 보철물 장착 후 초기 6개월간의 마모 비교에서 지르코니아 전장관과 금전장관은 유의한 차이가 없었고, 대합되는 자연치 법랑질의 마모도 유의한 차이는 없었다.

임플란트 보철물의 임상적 합병증에 관한 고찰 (Prosthodontic problems and complications associated with osseointegration)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제31권4호
    • /
    • pp.349-357
    • /
    • 2015
  • 무치악 환자에 있어서 골유착 임플란트는 통상의 다른 보철수복방법과 비교했을 때, 기능적으로나 환자의 만족도 면에 있어서 아주 좋은 결과를 보이며, 삶의 질 향상에도 가장 우수한 것으로 알려져 있다. 골질이 양호하고 골량이 충분한 부위에 외과적으로 많은 수의 임플란트를 적절히 식립하여, 최상의 임플란트 보철물 설계가 가능하게 배열되는 것이 바람직하나, 아직까지는 환자와 치과의사 모두에게 합병증과 여러 문제들이 한계로 남아 있다. 골유착에 관한 보철적인 문제, 즉 임플란트 실패, 보철물의 부적합, 임플란트 구성요소의 파절, 그리고 나사 풀림 등 합병증에 관해 분석하고 그에 관한 증례를 보고하고자 한다.

심하게 흡수된 하악골에서 fixed detachable prosthesis를 이용한 임플란트 지지 보철 수복증례 (Implant supported prosthetic rehabilitation of severely atrophic mandible with fixed detachable prosthesis)

  • 이학주;임영준;권호범;김명주
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.180-186
    • /
    • 2017
  • 완전 무치악 환자에서 임플란트를 이용한 치료 방법은 환자의 삶의 질 개선에 크게 기여하였으나, 잔존골 상태나 경제력 등에 의해 임플란트의 식립 개수에 제한을 받는 상황이 종종 나타난다. 이러한 경우 일반적으로 임플란트 피개의치나 임플란트 융합 국소의치 형태로 치료계획을 세울 수 있지만, 정확한 설계를 바탕으로 양측성 캔틸레버 형태의 고정성 보철물 역시 고려해 볼 수 있다. 본 증례에서는 심한 치조골 흡수를 보이는 완전 무치악 환자에서 상악 총의치 및 하악 임플란트 지지 고정성 캔틸레버 보철물 제작을 통해 기능적, 심미적으로 양호한 결과를 얻었기에 보고하고자 한다.

하악 무치악 환자에서 임플란트 하이브리드형 보철물을 이용한 전악 수복 증례 (Full mouth rehabilitation of mandibular edentulous patient using implant hybrid prosthesis)

  • 김현숙;김소현;오남식
    • 대한치과보철학회지
    • /
    • 제56권1호
    • /
    • pp.25-30
    • /
    • 2018
  • 무치악 환자에서 임플란트 고정성 보철 수복의 장점은 안정성, 편안함을 들 수 있으며, 생물학적 측면으로는 하악골 흡수를 방지할 수 있고 저작기능이 향상된다는 이점이 있다. 그중 하이브리드형 보철 수복은 하악골 이공사이에 4 - 6개의 임플란트를 식립하고 양쪽 원심으로 캔틸레버를 만들어 구치부 치아를 대체하게 된다. 본 증례는 85세 여성 환자로 상하악의 무치악 상태로 본원에 내원하였다. 상악의 가철성 총의치, 하악의 임플란트 하이브리드형 보철물로 최종 치료하여 치료 후 기능적, 심미적으로 만족스러운 결과를 얻었기에 이를 보고하고자 한다.

Multiple implant therapy with multiple inductions of general anesthesia in non-compliant patients with schizophrenia: A case report

  • Choi, Yong-suk;Kim, Hyungseok;Rhee, Seung-Hyun;Ryoo, Seung-Hwa;Karm, Myong-Hwan;Seo, Kwang-Suk;Kim, Hyun Jeong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제19권4호
    • /
    • pp.239-244
    • /
    • 2019
  • The effectiveness of dental implants in patients with disability, who are non-compliant during treatment, is controversial because of their poor oral health. Thus, oral health-care and management in such patients is concerning. Moreover, limited information is available on prognosis after implant placement. Herein, we describe a patient with schizophrenia who underwent dental implantation under multiple inductions of general anesthesia (5 times) and required conservative treatment and tooth extraction for multiple dental caries and retained roots because of inadequate oral health-care. Postoperatively, fracture of the prosthodontics and progression of dental caries were observed, and with 3 additional inductions of general anesthesia, conservative treatment, implant surgery, and prosthesis implantation were conducted. Postoperative 12-month follow-up since the last prosthesis implantation showed successful results. For patients with schizophrenia, multiple implantation can reduce horizontal bone loss and achieve aesthetic results compared to treatment with removable prosthodontics and could serve as an alternative treatment modality.

디지털 안궁이전과 가상교합기를 이용하여 하악의 운동을 고려한 구치부 수복 증례 (Posterior rehabilitation considering mandibular movement with digital facebow transfer and virtual articulator: A case report)

  • 김민범;권호범;임영준;김명주
    • 대한치과보철학회지
    • /
    • 제60권4호
    • /
    • pp.431-441
    • /
    • 2022
  • 디지털 안궁이전 장치로 하악의 운동로를 기록하고 캐드 소프트웨어(CAD software) 상에 반영할 수 있는데 이를 고려한 보철 수복은 치료 결과를 향상시킨다. 본 증례는 상하악 대구치가 소실된 환자에서 디지털 기술을 활용하여 임플란트를 식립 및 보철 수복한 증례이다. 구내 스캔 후 디지털 진단 왁스업을 토대로 임플란트 수술용 가이드를 제작한 뒤 임플란트 식립했다. 6개월의 충분한 골유착 후, 맞춤형 지대주와 첫번째 임시 보철물을 장착하였다. 2개월 후 지대주 수준에서 구강 스캔 및 디지털 안궁이전 장치로 가상 교합기 상마운팅하고 하악 운동을 기록했다. 하악의 움직임을 고려하여 두번째 임시 보철물을 제작, 장착 후 안정된 교합 상태에서 더블 스캔 과정으로 복제하여 지르코니아 최종 보철물을 디자인하고 장착했다.

Ten-year follow-up of full mouth rehabilitation with fixed prostheses using implants and natural tooth

  • So-Young Park;Seung-Geun Ahn;Jung-Jin Lee;Yeon-Hee Park;Kyoung-A Kim;Jae-Min Seo
    • 구강회복응용과학지
    • /
    • 제40권3호
    • /
    • pp.189-200
    • /
    • 2024
  • 전악 고정성 보철 수복을 통해 이상적인 교합을 새롭게 설정해준 환자에서 시간이 지남에 따라 다양한 원인에 의해 합병증과 교합의 변화가 나타날 수 있다. 본 증례에서는 저작 장애와 심미적 문제로 인해 수직고경 증가를 동반한 전악 지르코니아 보철물을 수복한 환자의 10년간 경과를 관찰하였다. 경과 관찰 동안 지대치의 파절, 교합양식의 변화, 그리고 일부 임플란트 보철물의 저위 교합과 인접면 접촉상실 등이 발생하였다. 이러한 문제점들은 치료 후 주기적인 점검을 통해 조기에 발견하는 것이 중요하며, 본 증례에서 발생한 합병증의 원인 및 대처법에 대해 고찰해 보고자 한다.

디지털 인상법과 전통적 인상법의 정확도 비교: 체계적 고찰 (Comparison of the accuracy of digital impressions and traditional impressions: Systematic review)

  • 김경록;서권수;김선재
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.258-268
    • /
    • 2018
  • 목적: 본 연구는 보철물의 적합 및 인상의 정확성에 관한 문헌들을 체계적으로 고찰하여 구강 내 스캐너를 이용한 디지털 인상법이 전통적인 인상법을 대체할 만한 정확도를 보이는지 알아보고자 한다. 재료 및 방법: 1997년 8월 1일부터 2017년 7월 31일까지 출판된 영어로 쓰여진 연구를 대상으로 디지털 인상법의 정확성에 대한 문헌을 MEDLINE/PubMed 전자 검색 및 수기탐색을 시행하였다. 조건에 따라 선택된 연구의 데이터를 스프레드 시트에 2명의 검토자가 독립적으로 정리하였다. 결과: 총 35개의 연구가 선택되었고, 26개의 연구는 보철물의 적합성을 비교하였고 9개의 연구는 보철물 없이 스캔 데이터를 통해 인상의 정확성을 비교하였다. 대부분의 연구가 보철물을 이용해 인상법의 정확성을 비교하였다. 결론: 본 고찰에 따르면 자연치열에서 디지털 인상법으로 단일관이나 근원심으로 길이가 짧은 보철물을 제작하는 것은 임상적으로 충분히 신뢰할만한 하다. 그러나 디지털 인상법으로 길이가 긴 보철물을 제작하는 것은 연구가 적어 아직 한계가 있다. 임플란트 보철물 제작에 있어서 구내스캐너를 이용한 디지털 인상법으로 전통적인 인상법을 완전히 대체하기는 아직 어렵다.

골조직과 임플랜트 계면의 최소접촉분율에 관한 삼차원 유한요소분석적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MINIMUM CONTACT FRACTION OF BONE-IMPLANT INTERFACE)

  • 장경수;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.627-646
    • /
    • 1997
  • In order to find the degree of osseointegration at bone-implant interface of clinically successful implants, models including the 3.75mm wide, 10mm long screw type $Br{\aa}nemark$ implant as a standard and cylinder, 15mm long, 5.0mm wide, two splinted implants, and implants installed in various cancellous bone density were designed. Also, the amount of load and material of prostheses were changed. The stress and minimum contact fraction were analyzed on each model using three-dimensional finite element method(I-DEAS and ABAQUS version 5.5). The results of this study were as follows. 1. 10mm long, 3.75mm diameter-screw type implant had $36.5{\sim}43.7%$ of minimum contact fraction. 2. Cylinder type implant showed inferior stress distribution and higher minimum contact fraction than screw type. 3. As implant length was increased, minimum contact fraction was increased a little, however, maximum principal stress was decreased. 4. Implants with a large diameter had lower stress value with slightly higher minimum contact fraction than standard screw type. 5. Two splinted implants showed no change of minimum contact fraction. 6. The higher bone density, the lower stress value. 7. The material of occlusal surface had no effect on the stress of the bone-implant interface.

  • PDF