• Title/Summary/Keyword: Implant placement

Search Result 641, Processing Time 0.025 seconds

Diagnostic keys of the overcoming risk factors and achieving predictable esthetics in anterior single implant

  • Choi, Geun-Bae;Yang, Jong-Sook
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.16 no.2
    • /
    • pp.7-18
    • /
    • 2007
  • There is now an increased demand for harmony between the peri-implant gingiva and adjacent dentition. In the event of a pending loss of a single tooth in the aesthetic zone with healthy periodontium, expectation for optimal gingival and prosthodontic aesthetics are often very high. Unfortunately, bone resorption is common following the removal of an anterior tooth, compromising the gingival tissue levels for the eventual implant restoration. Also, improper implant placement and inadequate osseous-gingival support potentially deleterious aesthetic result. The creation of an esthetic implant restoration with gingival architecture that harmonizes with the adjacent dentitionis formidable challenge. The predictability of the peri-implant esthetic outcome may ultimately be determined by the patient's own presenting anatomy rather than the clinician's ability to manage state-of-the-art procedures. To more accurately predict the peri-implant esthetic outcome before removing a failing tooth, a considering of diagnostic keys is essential. This presentation addresses the useful diagnostic keys that affect the predictability of peri-implant gingival aesthetics and the overcoming of the risk factors in anterior single-tooth replacement; it also describes a surgical and prosthodontic technique in achieving a long term successful esthetic outcome. Proper diagnosis and understanding of the biological and periodontal variables of failing dentition and their response to surgical and prosthodontic procedures are the essence of predictability. Using a smart protocol that alters the periodontium toward less risk and more favorable assessment of the diagnostic keys before implant placement will provide the most predictable esthetic outcome. Simple diagnostic keys suggested this presentation are useful method to evaluate the overcoming of the risk factors in anterior single implant restoration.

  • PDF

Clinical problems of computer-guided implant surgery

  • Moon, Seong-Yong;Lee, Kyoung-Rok;Kim, Su-Gwan;Son, Mee-Kyoung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.15.1-15.6
    • /
    • 2016
  • Background: The utilization of a cone-beam computed tomography (CT)-assisted surgical template allows for predictable results because implant placement plans can be performed in the actual surgery. In order to assess the accuracy of the CT-guided surgery, angular errors and shoulder/apex distance errors were evaluated by data fusion from before and after the placement. Methods: Computer-guided implant surgery was performed in five patients with 19 implants. In order to analyze differences of the implant fixture body between preoperative planned implant and postoperative placed implant, angular error and distance errors were evaluated. Results: The mean angular errors between the preoperative planned and postoperative placed implant was $3.84^{\circ}{\pm}1.49^{\circ}$; the mean distance errors between the planned and placed implants were $0.45{\pm}0.48mm$ horizontally and $0.63{\pm}0.51mm$ vertically at the implant neck and $0.70{\pm}0.63mm$ horizontally and $0.64{\pm}0.57mm$ vertically at the implant apex for all 19 implants. Conclusions: It is important to be able to utilize these methods in actual clinical settings by improving the various problems, including the considerations of patient mouth opening limitations, surgical guide preparation, and fixation.

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.

Survival rate of implant placement in the maxilla treated with sinus elevation by the lateral approach : A retrospective study (측방 접근법을 이용하여 상악동 거상술을 시행한 부위에 식립한 임플란트의 생존율에 대한 후향적 연구)

  • Lee, Eun-Sun;Ahn, Yong-Bum;Lee, Won-Jin;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.589-594
    • /
    • 2008
  • Purpose: Osseointegration of implants in patients with pneumatized maxillary sinuses is difficult to achieve due to the deficiency of available bone in the posterior maxilla after loss of teeth. Maxillary sinus elevation is a method to overcome this problem. In this study, we evaluated the implant survival rate and the relationship between implant survival in patients with sinus elevation by the lateral approach. Materials and Methods: A total of 48 patients were consecutively treated with sinus elevation by the lateral approach between February 2003 & August 2006 at the dental hospital of Chonbuk National university. A total of 113 implants were placed. The mean healing period was 7.1 months and implants were placed after a mean period of 5.6 months. The mean observation period was 21.8 months. Results: Out of the 113 implants placed, fifteen failed, resulting in a survival rate of 86.7%, 18 cases of sinus membrane perforation were observed out of 65 sinuses treated. 33 implants were placed in a perforated site and 10 failed, representing a 60.7% implant survival. 80 implants were placed in a nonperforated site and 5 failed, representing a 92.6% implant survival. Conclusions: Implant placement with sinus elevation is an acceptable treatment for short term results. Sinus membrane perforation and postoperative complications, however, may have an effect on implant failure.

A Retrospective clinical study of survival rate of single implant in maxillary anterior teeth (상악 전치부 단일 임플란트의 생존율에 대한 후향적 연구)

  • Im, Ji-Soon;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Chai, Jung-Kyu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.639-651
    • /
    • 2006
  • This study was performed to investigate the survival rate of single implant used in maxillary anterior region during follow up periods. 231 patients whose single missing tooth in maxillary region had been replaced with 237 implant at the periodontal dept. of Yonsei University Hospital between February 1993 and December 2004. The following results are compiled from 231 patients who received single implant surgery. 1. The major cause of single tooth loss in maxillary anterior region is trauma, followed by periodontal disease and congenital missing. 2. The total survival rate of single implant placed in maxillary anterior region is 94.5%. 3. The survival rate of single implant placed in type II and type IV was 100% and in type III was 92.7%. As for the bone quantity, the survival rate in type A(100%) was most, followed by type B(97.3%) and type C, D (93.5%). 4. The survival rate of implant placement combined with advanced surgery was 94.4%. The results showed that the placement of single implant is considered as a reliable treatment option for a single missing tooth in maxillary anterior region except in certain extreme conditions especially with poor bone quality and quantity.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

Retrospective Study of Sandblasted, Large-grit and Acid-etched Implant (Sandblasted, Large-grit and Acid-etched Implant에 대한 후향적 임상 연구)

  • Jo, Ji-Ho;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Park, Jin-Ju;Jung, Jong-Won;Yoon, Dae-Woong;Yang, Seong-Su;Jeong, Mi-Ae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.4
    • /
    • pp.352-358
    • /
    • 2011
  • Purpose: This study evaluated the prognosis and survival rate of SLA (Sandblasted, Large-grit and Acid-etched) implants and it also evaluated the prosthodontic complications and the associated factors. Methods: Twenty seven patients (14 men and 13 women, mean age: 54.9) who visited Chosun University Hospital Implant Center with the chief desire for placement of an implant in an edentulous area from March, 2008 to December 2008 and who received placement of a SLA implant ($Implantium^{(R)}$, Dentium Co., Korea) were selected for this study. Results: The average follow-up period was 15 months and the study was based on the treatment records, radiographs and clinical examinations. A total of 69 implant cases were retrospectively assessed for the width and length of the implant, the primary and secondary stability, the combined surgery, the employed bone graft material and barrier membrane, the status of the opposing tooth, implant failure and the prosthetic complications. During the follow-up period (average: 15 months), the accumulative survival rate of the 69 implants in 27 patients was 100%. Complications such as infection, sinusitis and fixture exposure after surgery were seen for 5 implants in 4 patients. Complications such as screw loosening, contact loosening and peri-implant gingivitis after prosthodontic treatment occurred in 7 cases (10.14%). Conclusion: This study reports placement of SLA implants may cause various complications, yet the final accumulative survival rate was 100%. The SLA implant ($Implantium^{(R)}$) has an excellent clinical survival rate and outcome.

Clinical Study on the Survival Rate and Marginal Bone Resorption of Short Implants (짧은 임플란트의 생존율과 변연골 흡수량에 관한 임상적 연구)

  • Myung, Tae-Soo;Jung, Seung-Hyun;Kim, Tae-Young;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Short implants are used in parts which have anatomical structures like maxillary sinus, inferior alveolar nerve and limited alveolar height due to severe alveolar bone resorption. In these case, there are no need of additional bone augmentation so there are advantages like reduced entire treatment time, reduced patient's discomfort and protection of important anatomical structures. The aim of this study is, in implants whose length is less than 10mm, to analyze the impact of implant length, diameter, location of implant placement, presence of bone graft, presence of prosthesis splinting on survival rates and marginal bone resorption. The samples used in this study were 227 implants, less than 10mm, placed in 137 patients in Wonkwang university dental hospital implant center. From dental charts the information about implant length, diameter, location of implant placement, presence of bone graft, presence of prosthesis splinting were obtained. Emago advanced v5.6(Oral diagnostic systems, Amsterdam, The Netherlands)program was used to measure the amount of marginal bone resorption. Out of total 227 implants, resulting in 96.5 % of survival rate. There was a tendency toward higher failure rates for the maxilla and bone graft site. No significant difference in marginal bone resorption was found associated with length of implants(p>0.05) and neither with the diameter of implants. Among the risk factors examined, more failure rates of short implants can be attributed to poor bone quality in the maxilla and presence of bone graft. At implants under 10mm, length, diameter, location of implant placement, bone graft and splinting of prosthesis didn't affect marginal bone loss.

Horizontal ridge expansion and implant placement using screws: a report of two cases

  • Kim, Young-Kyun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.5
    • /
    • pp.233-239
    • /
    • 2014
  • Implants are typically placed after performing ridge expansion by inserting screws of gradually increasing thickness and good clinical outcomes are often obtained. We placed 11 implants in 6 patients, and one implant failed during osseointegration but it was replaced immediately after removal and successful prosthetic treatments were completed. During these surgeries, buccal cortical plate complete fractures do not occur. Inserting screws for ridge expansion is a successful and predictable technique for implant placement in narrow alveolar bone.

Implant Placement in Growing Adolescents : a Literature Review (성장기 소아 청소년 환자에서의 치과 임플란트 식립)

  • Shin, Hyun-Seung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.270-274
    • /
    • 2015
  • Although there are a number of studies on the treatment planning and the prognosis of dental implants, limited studies provide the information on the implant placement on growing adolescents. The aim of this review is to discuss the use of dental implants in growing patients and the impact of skeletal and dentoalveolar growth on the long-term stability of implants. The general information regarding skeletal growth of maxilla and mandible would be briefly reviewed and the general treatment options would be discussed.