• 제목/요약/키워드: Implant complication

검색결과 199건 처리시간 0.022초

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.

임프란트 수술 및 보철물에 따른 합병증 연구 (Study about the complications associated with implant surgery and prosthetic treatment)

  • 이지영;김영균;윤필영;배지현;김재승
    • 대한치과의사협회지
    • /
    • 제47권9호
    • /
    • pp.585-595
    • /
    • 2009
  • Purpose : The aim of this study was to compare surgical complications between simple implant placement and implant placement combined with complicated surgical procedures. We also evaluated prosthetic complications according to the specific types of prosthesis. Material and Method : A retrospective analysis of dental chart of patients who was performed implant therapy during the period from June 2003 to December 2005 was carried out. This study was performed on 408 patients (208 male, 200 female). In addition, 1671 implants were performed. Based on their medical record and radiographs, the authors evaluated surgical and prosthetic complications, surgical procedures accompanied at the time of implant, risk factors of implant failure etc. Result : Surgical complications were developed on 358 implants(21.4% on total placed implants) and wound dehiscence was most prevalent complication. On maxillary posterior area, surgical complications developed more frequently on implants with major surgery and showed a significant difference. And complication rate of implants accompanied with GBR was higher than that of simple implants placement and also showed significant difference. The implant supported prosthesis showed no statistical difference in the occurrence of complications according to the types of prosthesis, and food retention was the most common post-prosthetic complication. Also we speculated that length and width of implant showed significant correlation to the failure of implant primary osseointegration. Conclusion : Based on the result, clinician should provide more careful maintenance for patients with implant placement accompanied by complicated surgical procedure. And periodic maintenance for the patient is requested for long-term survival of implant therapy.

  • PDF

The prognosis of splinted restoration of the most-distal implants in the posterior region

  • Lee, Jong-Bin;Kim, Man-Yong;Kim, Chang-Sung;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.494-503
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the efficacies of two-implant splinting (2-IS) and single-implant restoration (1-IR) in the first and second molar regions over a mean functional loading period (FLP) of 40 months, and to propose the appropriate clinical considerations for the splinting technique. MATERIALS AND METHODS. The following clinical factors were examined in the 1-IR and 2-IS groups based on the total hospital records of the patients: sex, mean age, implant location, FLP, bone grafting, clinical crown-implant ratio, crown height space, and horizontal distance. The mechanical complications [i.e., screw loosening (SL), screw fracture, crown fracture, and repeated SL] and biological complications [i.e., peri-implant mucositis (PM) and peri-implantitis (PI)] were also evaluated for each patient. In analysis of two groups, the chi-square test and Student's t-test were used to identify the relationship between clinical factors and complication rates. The optimal cutoff value for the FLP based on complications was evaluated using receiver operating characteristics analysis. RESULTS. In total, 234 patients with 408 implants that had been placed during 2005 - 2014 were investigated. The incident rates of SL (P<.001), PM (P=.002), and PI (P=.046) differed significantly between the 1-IR and 2-IS groups. The FLP was the only meaningful clinical factor for mechanical and biological complication rates in 2-IS. CONCLUSION. The mechanical complication rates were lower for 2-IS than for 1-IR, while the biological complication rates were higher for 2-IS. FLP of 39.80 and 46.57 months were the reference follow-up periods for preventing biological and mechanical complications, respectively.

Overcoming and Preventing Dental Implant Complications: Abutment Fracture Case Report

  • Kahm, Se Hoon;Kim, Chang-Hyun;Kim, Sung-Joon
    • Journal of Korean Dental Science
    • /
    • 제6권1호
    • /
    • pp.27-33
    • /
    • 2013
  • The introduction of osseointegrated dental implants in dentistry brought about a new era in everyday dental practice. For the past 50 years, prosthetic restoration with implant-supported prosthesis has developed into a viable and predictable treatment option. Alongside the increasing use of dental implants is the occurrence of many complications during implant placement (surgery), in the mechanical or prosthetic problem, and in the biological aspect. In particular, abutment or screw fracture as one of the mechanical complications can put the dentist in a tight spot in a clinical situation. It is hard to remove the fractured abutment and screw to restore it properly. Therefore, it is very important that clinicians consider possible complications in advance and make an appropriate treatment plan. We discuss cases of abutment fracture and mechanical/prosthetic complications together with the causes and solutions.

Benign paroxysmal positional vertigo as a complication of sinus floor elevation

  • Kim, Moon-Sun;Lee, Jae-Kwan;Chang, Beom-Seok;Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • 제40권2호
    • /
    • pp.86-89
    • /
    • 2010
  • Purpose: Osteotome sinus floor elevation (OSFE) is an often-used technique of great utility in certain implant patients with resorbed posterior maxilla. Recently benign paroxysmal positional vertigo (BPPV) has been reported as an early postoperative complication following OSFE. Although OSFE-induced BPPV commonly resolves itself within a month without treatment, this complication can be a cause of trouble between the implant surgeon and patient. This report presents a case of BPPV following OSFE. Methods: A 27-year-old man without any significant medical problems and missing his maxillary right first molar, was scheduled for OSFE and simultaneous implant placement. Results: The patient suffered dizziness accompanied by nausea immediately after implant placement using OSFE. Following referral to the ear nose throat clinic, "right posterior canal BPPV" was diagnosed. Despite anti vertigo medication and a single episode of the Epley maneuver, the condition did not improve completely. The Epley maneuver was then applied 7 and 8 days later and the symptoms of BPPV disappeared. One year later, the patient remained symptom-free. Conclusions: Before sinus elevation with an osteotome, implant surgeons should screen out patients with a history of vertigo, to diminish the possibility of BPPV. Operators should be aware of BPPV symptoms. As the symptoms may be very incapacitating, immediate referral to an otorhinolaryngologist is recommended.

Blossom smart expander technology for tissue expander-based breast reconstruction facilitates shorter duration to full expansion: A pilot study

  • Choi, Youna K.;Rochlin, Danielle H.;Nguyen, Dung H.
    • Archives of Plastic Surgery
    • /
    • 제47권5호
    • /
    • pp.419-427
    • /
    • 2020
  • Background This study evaluated the Blossom system, an innovative self-filling, rate-controlled, pressure-responsive saline tissue expander (TE) system. We investigated the feasibility of utilizing this technology to facilitate implant-based and combined flap with implant-based breast reconstruction in comparison to conventional tissue expansion. Methods In this prospective, single-center, single-surgeon pilot study, participants underwent either implant-based breast reconstruction or a combination of autologous flap and implantbased breast reconstruction. Outcome measures included time to full expansion, complications, total expansion volume, and pain scores. Results Fourteen patients (TEs; n=22), were included in this study. The mean time to full expansion was 13.4 days (standard error of the mean [SEM], 1.3 days) in the combination group and 11.7 days (SEM, 1.4 days) in the implant group (P=0.78). The overall major complication rate was 4.5% (n=1). No statistically significant differences were found in the complication rate between the combination group and the implant group. The maximum patient-reported pain scores during the expansion process were low, but were significantly higher in the combination group (mean, 2.00±0.09) than in the implant group (mean, 0.29±0.25; P=0.005). Conclusions The reported average duration for conventional subcutaneous TE expansion is 79.4 days, but this pilot study using the Blossom system achieved an average expansion duration of less than 14 days in both groups. The Blossom system may accommodate single-stage breast reconstruction. The overall complication rate of this study was 4.5%, which is promising compared to the reported complication rates of two-stage breast reconstruction with TEs (20%-45%).

Bisphosphonate를 복용하는 환자에게 임프란트 치료시 고려사항 (Considerations during dental implant treatment for patients under bisphosphonate therapy)

  • 박원서;정원윤;김형준;김기덕
    • 대한치과의사협회지
    • /
    • 제49권7호
    • /
    • pp.389-397
    • /
    • 2011
  • Bisphosphonate inhibits the function of osteoclast, so they are widely used for multiple myeloma, Paget's disease, metastatic malignant bone disease, and severe osteoporosis. This drug is very effective for preventing severe complication of osteoporosis, some unpredictable complication occurred such as esophageal malignancy, atypical fracture of femur, and osteonecrosis of the jaw. Bisphosphonate related osteonecrosis of the jaw (BRONJ) is closely related with invasive, open bone surgery like tooth extraction. BRONJ associated with dental implant is rare, however, as the use of bisphosphonate increase, BRONJ cases with dental implant are increasing. In this article, we will describe the considerations during dental implant treatment for patient under bisphosphonate therapy.

Gingival Sulcus Incision으로 제거된 Silicon Implant 삽입 후 발생한 안와내 낭종 (Removal of Silicon-associated Intraorbital Cyst with Gingival Sulcus Incision)

  • 권용석;김명훈;허정;이장호;이근철;김석권
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.29-32
    • /
    • 2009
  • Purpose: Alloplastic implants, such as $Silastic^{(R)}$, $Supramid^{(R)}$, Porous polyethylene, $Teflon^{(R)}$ have been used to prevent reherniation of orbital tissue and are known to be inert for many years, though complications are infrequently reported many years after their insertion. Complications associated with implants are infrequent, but infection, orbital hemorrhage, implant extrusion, motility restriction, migration of implant causing dacryocystitis, cystic formation have been described. The latter was known as a rare late complication of blow-out fracture repair. Methods: We report the case of a discovery of a intraorbital hemorrhagic cyst which developed after silicon implant insertion. This patient developed diplopia, unilateral proptosis, exophthalmos, vertical dystopia, ectropion 10 years after repair of blow-out fracture. In this case, orbital CT scan revealed intraorbital cyst surrounding the orbital implant. At surgery, a fibrous capsule surrounded the silicon implant and was filled with mucin pools. Results: Proptosis, diplopia, exophthalmos, ectropion, vertical dystopia were resolved after surgical removal of the cyst and implant. Conclusion: This case illustrate that it is important for us to be aware of the complication of cyst formation around the silicon implants.

Comparative study of prosthetic complications associated with the bar-clip, milled bar, and Locator attachments for implant overdentures: a retrospective study

  • Yoon, Kye-Won;Heo, Ji-Ye;Hwang, Hee-Sung;Kim, Chul-Hoon;Kim, Bok-Joo;Kim, Jung-Han
    • 대한치과의사협회지
    • /
    • 제54권12호
    • /
    • pp.1024-1034
    • /
    • 2016
  • Purpose. The purpose of this study was to compare the type and frequency of prosthetic complications associated with attachment types for implant overdenture. Material and methods. In this retrospective study, 38 patients (mean age, 63.5 years) have been treated with implant overdentures from 2007 to 2014. Ten patients received a bar-clip attachment. Eleven patients had received a milled bar with Locator attachment. Seventeen patients had received a Locator attachment. The mean follow-up period was 36.9 months (range, 15-83 months). The type and frequency of prosthetic complications was recorded. The frequency was analyzed to determine the statistical difference among the 3 different attachments by using one-way ANOVA (${\alpha}=.05$) and Bonferroni post hoc method at a 5% level of significance. Results. The total number of prosthetic complications was higher in the bar-clip attachment (55 events) than in the milled bar with Locator attachment (39 events) and the Locator attachment (34 events). There were no statistically significant differences, and the most common prosthetic complication was the loss of retention. In the bar-clip attachment group, the average frequency of prosthetic complications was 3.0 events per prosthesis during the first year. In the milled bar with Locator attachment and Locator attachment groups, the average frequencies were 1.45 events and 2.35 events, respectively. Statistically significant differences were observed in the frequency of the complication. (p = .043) Conclusions. Compared to the bar-clip attachment, implant overdentures that use milled bars with the Locator attachment have a significantly lower incidence of prosthetic complications in the first year of follow-up after placement.

  • PDF

A retrospective comparison of clinical outcomes of implant restorations for posterior edentulous area: 3-unit bridge supported by 2 implants vs 3 splinted implant-supported crowns

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.223-235
    • /
    • 2022
  • PURPOSE. To compare the clinical outcomes of two types of implant restoration for posterior edentulous area, 3-unit bridge supported by 2 implants and 3 implant-supported splinted crowns. MATERIALS AND METHODS. The data included 127 implant-supported fixed restorations in 85 patients: 37 restorations of 3-unit bridge supported by 2 implants (2-IB), 37 restorations of 3 implant-supported splinted crowns (3-IC), and 53 single restorations (S) as controls. Peri-implantitis and mechanical complications that occurred for 14 years were analyzed by multivariable Cox regression model. Kaplan-Meier curves and the multivariable Cox regression model were used to analyze the success and survival of implants. RESULTS. Peri-implantitis occurred in 28.4% of 2-IB group, 37.8% of 3-IC group, and 28.3% of S control group with no significant difference. According to the implant position, middle implants (P2) of the 3-IC group had the highest risk of peri-implantitis. The 3-IC group showed a lower mechanical complication rate (7.2%) than the 2-IB (16.2%) and S control group (20.8%). The cumulative success rate was 52.8% in S (control) group, 62.2% in 2-IB group, and 60.4% in 3-IC group. The cumulative survival rate was 98.1% in S (control) group, 98.6% in 2-IB group, and 95.5% in 3-IC group. There was no significant difference in the success and survival rate according to the restoration type. CONCLUSION. The restoration type was not associated with the success and survival of implants. The risk of mechanical complications was reduced in 3 implant-supported splinted crowns. However, the middle implants of the 3 implant-supported splinted crowns had a higher risk of peri-implantitis.