• 제목/요약/키워드: Implant abutment

검색결과 508건 처리시간 0.023초

Three-dimensional finite element analysis of platform switched implant

  • Moon, Se-Young;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.31-37
    • /
    • 2017
  • PURPOSE. The purpose of this study was to analyze the influence of the platform switching concept on an implant system and peri-implant bone using three-dimensional finite element analysis. MATERIALS AND METHODS. Two three-dimensional finite element models for wide platform and platform switching were created. In the wide platform model, a wide platform abutment was connected to a wide platform implant. In the platform switching model, the wide platform abutment of the wide platform model was replaced by a regular platform abutment. A contact condition was set between the implant components. A vertical load of 300 N was applied to the crown. The maximum von Mises stress values and displacements of the two models were compared to analyze the biomechanical behavior of the models. RESULTS. In the two models, the stress was mainly concentrated at the bottom of the abutment and the top surface of the implant in both models. However, the von Mises stress values were much higher in the platform switching model in most of the components, except for the bone. The highest von Mises values and stress distribution pattern of the bone were similar in the two models. The components of the platform switching model showed greater displacement than those of the wide platform model. CONCLUSION. Due to the stress concentration generated in the implant and the prosthodontic components of the platform switched implant, the mechanical complications might occur when platform switching concept is used.

TiN 코팅된 지대주 나사의 반복 착탈 후 표면 변화와 적합도에 관한 연구 (SURFACE CHANGE AND FIT OF TIN-COATED ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING)

  • 김종남;정재헌;김희중
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.119-130
    • /
    • 2007
  • Statement of problem: A few dry lubricants were applied to abutment screws for the improvement of joint stability. Purpose: The purpose of this study was to evaluate the surface change and fit of TiN-Coated abutment screw through the examination of tested screws in the field emission scanning electron microscope(FE-SEM;Netherland, Phillips co., model:XL 30 SFEG) after repeated closing and opening. Materials and method: Titanium(3i/implant Innovations Inc, USA) and Gold-Tite abutment screws(3i/implant Innovations Inc, USA) were selected for Group A and C respectively. TiN coated titanium abutment screws were also divided into two groups, Group B and D. Abutment screws of each group and the fit of abutment screw/implant fixture/abutment were observed on FE-SEM after repeated closing and opening test respectively. Results: 1. The abutment screws of TiN coated groups(Group B and D) showed more remarkable wear resistance in the threads of the screw than those of the other group(Group A and C). 2. There were more severe wear and defect of TiN coating in Group D tightened to 32 Ncm than Group B to 20 Ncm. 3. There was no difference in the fit of abutment screw/fixture/abutment among four groups, Group A, Group B, Group C and Group D. Conclusion: Under the conditions of this study, it is suggested that TiN coating of abutment screw be clinically acceptable and be expected to reduce the risk of abutment screw loosening. TiN coating of abutment screw showed good resistance against wear and the adequate fit of abutment screw/implant fixture/abutment.

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • 제52권6호
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.

임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석 (3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs)

  • 이성천;김석규
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.365-375
    • /
    • 2009
  • 연구목적: 임플란트 보철물의 유지형태 중 나사 및 시멘트 혼합 유지형의 경우 나사 풀림력 등에 영향을 주는 임플란트 구성 성분의 응력에 관한 연구가 부족하였다. 임플란트 상부 보철물의 유지형태, 즉, 시멘트 유지와 나사 유지, 그리고 이 두 가지 유지형태가 서로 연결된 혼합형의 임플란트 보철물의 응력분산의 특징들을 3차원 유한요소분석법을 이용하여 비교하고자 하였다. 연구재료 및 방법: 하악골에서 제1소구치 부위와 제1대구치 부위에 2개의 임플란트 (SS II, Osstem Co. Ltd., Seoul, Korea)를 식립한 가상의 3본 계속가공의치를 모델화하였다. 지대주 종류와 그 위치에 따라, 4가지 모형 군으로 나누어 실험하였다. 모형 1은제1대구치와 제1소구치 각각의 고정체에 모두 동일한 시멘트 유지형 지대주인 Comocta abutment (Osstem Co. Ltd) 를 장착하여 3본 계속가공의치를 합착시킨 경우이고, 모형 2는 제1대구치와 제1소구치 각각의 고정체에 모두 나사 유지형 지대주인 Octa abutment (Osstem Co. Ltd) 를 장착하여 3본 계속가공의치를 나사로 고정시킨 경우이며, 모형 3은 제1대구치의 고정체에는 시멘트 유지형 지대주인 Comocta abutment를 장착하고, 제1소구치에는 나사 유지형 지대주인 Octa abutment를 장착한 후 3본 계속가공의치를 각각 시멘트 합착 및 나사로 고정시킨 경우이다. 그리고 모형 4는 모형 3에서 각각 제1대구치 및 제1소구치의 지대주를 맞바꾼 후 3본 계속가공의치를 나사 및 시멘트로 고정시킨 경우로 나누었다. 평균저작압인 하중을 대구치 565 N과 소구치 288 N의 힘으로 설정하고 수직방향으로 중심와와 협측 교두정에, 그리고 $30^{\circ}$ 경사 하중을 협측 교두정 부위에 준 다음 골, 고정체, 지대주, 그리고 지대주 나사 등에 나타나는 von-Mises stress 양상을 평가하였다. 결과: 네 가지 모형 중 나사 유지형 지대주인 Octa abutment를 제1대구치와 제1소구치 부위에 사용한 모형 2가 전반적으로 가장 낮은 안정적인 응력 분포를 보였다. 네 가지 모형 모두 피질골 및 고정체에 미치는 응력 크기 및 분포는 거의 유사하며, 치조골에 작용하는 응력은 하중의 종류와 상관없이 주로 피질골에 집중되었다. 지대주, 지대주 나사, 그리고 보철물 나사 등에 미치는 응력 크기나 분포는 모형에 관계없이 나사 유지형인 경우가 시멘트 유지형인 경우에 비해 낮은 안정적인 값을 보였다. 제1대구치와 제1소구치의 상부 구조물의 차이에 의한 교호작용 (reciprocal action)은 상대적으로 약하였다. 모든 부위에서 중앙 수 직하중, 교두정 수직하중, 그리고 교두정 경사하중의 순으로 응력값이 증가하였다. 결론: 본 유한 요소실험의 한계내에서 나사 및 시멘트 혼합 유지형의 임플란트 보철물은 시멘트 유지형만 사용하는 경우와 비교하여 주위에 더 큰 응력을 나타내지는 않았다. 이상적인 passive fit의 가정하에서 나사 유지형의 임플란트 보철물이 본체와 주위에 가장 작은 응력을 나타내었다.

지대주 각도와 연결방식이 지르코니아 지대주의 파절강도에 미치는 영향 (Effects of abutment angulation and type of connection on the fracture strength of zirconia abutments)

  • 김호성;조혜원
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.9-17
    • /
    • 2017
  • 목적: 내부 연결형과 외부 연결형의 임플란트에서 직선형과 경사형 지르코니아 지대주의 파절강도를 비교하였다. 재료 및 방법: 내부육각 연결형 임플란트 20개와 외부육각 연결형 임플란트 20개에, 기성 직선형 지르코니아 지대주와, $17^{\circ}$ 경사형 지르코니아 지대주를 10개씩 체결하였다. 시편은 연결 방식과 지대주 각도에 따라 4개의 군으로 나누었다: 내부 연결형/ 직선형 지대주, INS군; 내부 연결형/ 경사형 지대주, INA 군; 외부 연결형/ 직선형 지대주, EXS 군; 외부 연결형/ 경사형 지대주, EXA 군. 모든 시편은 만능시험기에서 1 mm/min의 crosshead speed로 $30^{\circ}$ 하중을 가했다. 지대주의 파절강도를 측정하고, 2-way ANOVA와 independent t-test로 통계처리 하였다(${\alpha}=.05$). 결과: 각 군의 평균파절강도는 다음과 같다: INS군, 955.91 N; INA군, 933.65 N; EXS군, 1267.20 N; EXA군, 1405.93 N. 외부 연결형이 내부 연결형에 비해 파절강도가 높았다(P < .001). 내부연결형(P = .747)과 외부 연결형(P = .222)에서 지대주 각도에 따른 파절강도는 차이가 없었다. 또한 내부 연결형 지대주는 육각 부위에서 수평 파절이 일어난 반면, 외부 연결형 지대주는 설측 치경부에서 파절되었다. 결론: 외부 연결형 지르코니아 지대주가 내부 연결형 지대주에 비해 파절 강도가 높았고, 직선형과 경사형 지르코니아 지대주의 파절강도는 차이가 없었다.

A COMPARATIVE STUDY OF THE 1-PIECE AND 2-PIECE CONICAL ABUTMENT JOINT: THE STRENGTH AND THE FATIGUE RESISTANCE

  • Kwon, Taek-Ka;Yang, Jae-Ho;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.780-786
    • /
    • 2007
  • Statement of problem. The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. Purpose. The Purpose of this study was to compare the strength and the fatigue resistance of 1-piece and 2-piece abutment connected to oral implant, utilizing an internal conical interface. Material and methods. Twenty $Implatium^{(R)}$ tapered implants were embedded to the top of the fixture in acrylic resin blocks. Ten $Combi^{(R)}$(1-piece) and $Dual^{(R)}$(2-piece) abutments of the same dimension were assembled to the implant, respectively. The assembled units were mounted in a testing machine. A load was applied perpendicular to the long axis of the assemblies and the loading points was at the distance of 7mm from the block surface. Half of 1-piece and 2-piece abutment-implant units were tested for the evaluation of the bending strength, and the others were cyclically loaded for the evaluation of the fatigue resistance until plastic deformation occurred. Nonparametric statistical analysis was performed for the results. Results. Mean plastic and maximum bending moment were $1,900{\pm}18Nmm,\;3,609{\pm}106Nmm$ for the 1-piece abutment, and $1,250{\pm}31Nmm,\;2,688{\pm}166Nmm$ for the 2-piece abutment, respectively. Mean cycles and standard deviation when implant-abutment joint showed a first plastic deformation were $238,610{\pm}44,891$. cycles for the 1-piece abutment and $9,476{\pm}3,541$ cycles for the 2-piece abutment. A 1-piece abutment showed significantly higher value than a 2-piece abutment in the first plastic bending moment (p<.05), maximum bending moment (p<.05) and fatigue strength (p<.05). Conclusion. Both 1-piece and 2-piece conical abutment had high strength and fatigue resistance and this suggests long-term durability without mechanical complication. However, the 1-piece conical abutment was more stable than the 2-piece conical abutment in the strength and the fatigue resistance.

The influence of the implant-abutment complex on marginal bone and peri-implant conditions: A retrospective study

  • Tokgoz, Selen Ergin;Bilhan, Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.46-54
    • /
    • 2021
  • Purpose. The design of the implant-abutment complex is thought to be responsible for marginal bone loss (MBL) and might affect the condition of the peri-implant tissues. This the present study aimed to evaluate the influence of the implant-abutment complex on MBL and the peri-implant tissues in partially edentulous patients treated with dental implants and determine the most advantageous design. Materials and Methods. A total of ninety-one endosseous implants with different designs of implant-abutment complex [tissue level-TL (n = 30), platform switch-PS (n = 18), and platform match-PM (n = 43)] were reviewed for MBL, Probing Pocket Depth (PPD) and Bleeding on Probing (BoP). MBL was calculated for first year of the insertion and the following years. Results. The median MBL for the PM implants (2.66 ± 1.67 mm; n = 43) in the first year was significantly higher than those for the other types (P=.033). The lowest rate of MBL (0.61 ± 0.44 mm; n = 18) was observed with PS implants (P=.000). The position of the crown-abutment border showed a statistically significant influence (P=.019) and a negative correlation (r=-0.395) on MBL. BoP was found significantly higher in PM implants (P=.006). The lowest BoP scores were detected in PS implants, but the difference was not significant (P=.523). The relation between PPD and connection type revealed no statistically significant influence (P>.05). Conclusion. Within the limitations of the present study, it may be concluded that PS implants seem to show better peri-implant soft tissue conditions and cause less MBL.

회전방지장치와 지대주의 내육각구조가 임플란트로 전달되는 조임 회전력에 미치는 영향 (EFFECT OF A COUNTER-TORQUE DEVICE AND THE INTERNAL HEXAGON OF ABUTMENT ON THE TIGHTENING TORQUE TRANSMITTED TO THE IMPLANT)

  • 이상민;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.223-231
    • /
    • 2003
  • Statement of problem : Little is known about the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Purpose : The purpose of this study was to examine the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Material and Methods : In this study, three types of abutment were used, (1) two-piece conical abutment with hexagon, (2) two-piece conical abutment without hexagon, and (3) one-piece conical abutment without hexagon. The experimental groups were divided into five groups according to the type of abutment and the usage of a counter-torque device. Group I : two-piece conical abutment with internal hexagon was tightened without the use of a counter-torque device. Group II : two-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group III : one-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group IV : two-piece conical abutment with internal hexagon was tightened with the use of a counter-torque device Group V : two-piece conical abutment without internal hexagon was tightened with the use of a counter-torque device. Abutments were tightened 20Ncm torque with the use of manual torque wrench and then torque values were measured by torque-gauge. After the measurement of torque values, all groups were loosened with the use of manual torque wrench and then detorque values were measured by torque-gauge. Results : The results were as follows. 1. There were no differences in torque values among three types of abutment. 2. Regardless of the existence of the internal hexagon of abutment, a counter-torque device decreased the tightening torque transmitted to the implant about 92% 3. In group III showed the highest detorque value, however there were no differences among group I, II, IV and V. Conclusion : Within the limitations of this study, it was concluded that the internal hexagon of abutment has no effect on the tightening torque transmitted to the implant and the detorque value of abutment screw. The use of a counter-torque device is essential to prevent microfracture on the implant-bone interface but has no effect on preload.

임플란트용 실링 어버트먼트의 개발 및 구조해석을 통한 성능분석 (Development of a Sealing-Type Abutment for Implant and the Performance Evaluation via Structural Analysis)

  • 김정민;홍대선
    • 한국정밀공학회지
    • /
    • 제33권9호
    • /
    • pp.769-775
    • /
    • 2016
  • Currently, dental implants are widely used as artificial teeth due to their good chewing performance and long life cycle. Generally, a dental implant consists of an abutment as the upper part and a fixture as the lower part. When chewing forces are repeatedly applied to a dental implant, a gap is often generated at the interfacial surface between the abutment and the fixture, and it results in some deterioration such as loosening of the fastening screw, dental retraction and fixture fracture. To enhance the sealing performance for coping with such problems, this study proposes a new sealing-type abutment having a number of grooves along the conical surface circumference, and it carries out finite element analysis in consideration of the external chewing force and pretension between the abutment and the fixture. The result shows that the proposed sealing-type abutment shows an enhanced sealing performance in terms of the contact pressure in comparison with a conventional abutment.

임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load)

  • 장종석;정용태;정재헌
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.