• 제목/요약/키워드: Implant Supported Fixed Prosthodontics

검색결과 159건 처리시간 0.024초

Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method

  • Tiossi, Rodrigo;Falcao-Filho, Hilmo Barreto Leite;De Aguiar, Fabio Afranio Junior;Rodrigues, Renata Cristina Silveira;De Mattos, Maria da Gloria Chiarello;Ribeiro, Ricardo Faria
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권2호
    • /
    • pp.89-92
    • /
    • 2012
  • PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C ($6.43{\pm}3.24{\mu}m$) when compared to Groups A ($16.50{\pm}7.55{\mu}m$) and B ($16.27{\pm}1.71{\mu}m$) ($P$ <.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, $58.66{\pm}14.30{\mu}m$; Group B, $39.48{\pm}12.03{\mu}m$; Group C, $23.13{\pm}8.24{\mu}m$) ($P$ <.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks.

하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석 (PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION)

  • 조혜원;김난영;김유리
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

임플란트 서베이드 보철물을 이용한 임플란트 보조 국소의치의 9년 경과 관찰 증례 (Implant assisted removable partial denture with implant surveyed prostheses: A 9-year follow-up)

  • 이재림;윤형인;김희선;심혜영;한윤식
    • 대한치과보철학회지
    • /
    • 제60권2호
    • /
    • pp.211-221
    • /
    • 2022
  • 완전 무치악 악궁을 수복함에 있어 해부학적인 한계 또는 경제적인 제한이 있거나 환자가 광범위한 수술을 원하지 않을 경우에 임플란트 식립이 제한될 수 있다. 이러한 경우 전악 임플란트 고정성 보철물의 대안으로 임플란트 보조 국소의치를 이용할 수 있다. 본 증례는 치주질환으로 다수 치아를 발거하여 상악 완전 무치악과 하악 부분 무치악이 된 56세 여성 환자에서 상악 전방부에 4개의 임플란트를 식립하여 8본 서베이드 보철물과 임플란트 보조 국소의치로 수복하였고, 하악은 전치부 8본 고정성 가공 의치 및 구치부 임플란트 고정성 보철물로 수복하였다. 9년 간의 경과 관찰 시 심미적, 기능적으로 적절한 결과를 얻었기에 이를 보고하고자 한다.

상악 전치부 고정성 보철물 수복 시 임시 임플란트를 이용한 임시보철물의 유지력 증가 증례보고 (Reinforcing the retention of provisional restoration using provisional implant on maxillary anterior region: clinical case report)

  • 김창대;문홍석;정문규;이재훈
    • 대한치과보철학회지
    • /
    • 제51권3호
    • /
    • pp.221-225
    • /
    • 2013
  • 임시 보철물의 적절한 관리는 보철의 성공에 있어서 중요한 요소이다. 상악 전치 결손부 임시 보철물은 장경간의 결손부가 존재하거나, 타원형의 악궁을 가진 환자에서 자주 탈락하게 된다. 이는 상악 전치부가 구치부에 비해서 수평적인 힘에 더 많이 노출되며, 부가적으로 전방 캔틸레버 효과가 임시 보철물의 유지를 저해하고, 상악 전치부 임시 보철물은 하악의 기능 운동시 적절한 전방 유도를 제공하여야 하기 때문이다. 또한 임시 보철물의 최대 감합위에서 교합접촉은 지점선의 반대편에 위치하게 되어 그 자체로 임시 보철물의 탈락을 야기한다. 본 증례에서는 임시 임플란트를 이용하여 상악 전치부 보철물에 대한 전술한 유해 작용을 피할 수 있었고, 발치 후 치유기간 동안 환자에게 편안함과 만족감을 부여하였으므로 이를 보고하는 바이다.

골유착성 임프란트와 자연치를 이용한 고정성 국소의치에서 응력분산 및 충격흡수에 관한 유한요소법적 응력분석 (A FINITE ELEMENT STRESS ANALYSIS OF THE STRESS DISTRIBUTION AND THE SHOCK ABSORPTION IN AN OSSEOINTEGRATED IMPLANT-NATURAL TOOTH SUPPORTED FIXED PARTIAL DENTURE)

  • 정창모;이호용
    • 대한치과보철학회지
    • /
    • 제30권4호
    • /
    • pp.582-610
    • /
    • 1992
  • The long-term success of any dental implant is dependent upon the optimization of stresses which occur during oral function and parafunction. Especially, it has been suggested that there is an unique set of problems associated with joining an osseointegrated implant and a natural tooth with a fixed partial denture. For this particular case, although many literatures suggest different ways to avoid high stress concentrations on the bone surrounding the implant under static and dynamic loading conditions, but few studies on the biomechanical efficacy of each assertion have been reported. The purpose of this investigation was to evaluate the efficacies of clinically suggested methods on stress distribution under static load and shock absorption under dynamic load, using two dimensional finite element method. In FEM models of osseointegrated implant-natural tooth supported fixed partial dentures, calculations were made on the stresses in surrounding bone and on the deflections of abutments and superstructure, first, to compare the difference in stress distribution effects under static load by the flexure of fastening screw or prosthesis, or intramobile connector, and second, to compare the difference in the shock absorption effects under dynamic load by intramobile connector or occlusal veneering with composite resin. The results of this analysis suggest that : 1. Under static load condition, using an implant design with fastenign screw connecting implant abutment and prosthesis or increasing the flexibility of fastening screw, or increasing the flexibility of prosthesis led to the .increase in height of peak stresses in cortical bone surrounding the implant, and has little effect on stress change in bone around the natural tooth. 2. Under static load condition, intramobile connector caused the substantial decrease in stress concentration in cortical bone surrounding the implant and the slight increase in stress in bone around the natural tooth. 3. Under dynamic load condition, both intramobile connector and composite resin veneering showed shock absorption effect on bone surrounding the implant and composite resin veneering had a greater shock absorption effect than intramobile connector.

  • PDF

임플란트와 레진 클래스프를 이용한 심미 가철성 국소의치 증례 (Esthetic removable partial denture with implants and resin clasp: Case report)

  • 김수민;전영찬;정창모;윤미정;허중보
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.58-65
    • /
    • 2015
  • 완전 무치악 환자의 수복 시 총의치나 임플란트 지지 피개의치와 더불어 임플란트를 지대치로 이용하는 국소의치가 치료 방법의 하나로 고려될 수 있다. 적은 수의 임플란트를 전략적으로 중요한 위치에 식립한 후 가철성 국소의치로 수복할 경우, 임플란트를 통해 안정을 얻고 부가적으로 유지 및 지지를 확보할 수 있을 뿐만 아니라 광범위한 임플란트 식립을 통한 고정성 보철물에 비해 환자의 수술 부담을 줄여줄 수 있으며, 치료비용 절감 효과도 기대할 수 있다. 본 증례는 오랫동안 국소의치를 사용해 온 환자에서 치아 상실 후 잔존 치조골의 상태 및 환자의 요구를 고려하여 임플란트 지지 국소의치를 제작한 증례로서 전치부에 식립한 임플란트는 고정성 보철물로 수복하고 구치부의 짧은 임플란트는 지지 기능만 부여하였다. 또한 의치상과 클래스프를 열가소성 아크릴 레진으로 제작함으로써 기능적, 심미적으로 만족스러운 치료 결과를 얻었기에 이를 보고하는 바이다.

Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Su-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.1-9
    • /
    • 2011
  • PURPOSE. This study investigated the strain of implants using a chewing simulator with strain gauges in mandibular implant-supported fixed prostheses under various dynamic loads. MATERIALS AND METHODS. Three implant-supported 5-unit fixed prostheses were fabricated with three different occlusion types (Group I: Canine protected occlusion, Group II: Unilaterally balanced occlusion, Group III: Bilaterally balanced occlusion). Two strain gauges were attached to each implant abutment. The programmed dynamic loads (0 - 300 N) were applied using a chewing simulator (MTS 858 Mini Bionix II systems, MTS systems corp., Minn, USA) and the strains were monitored. The statistical analyses were performed using the paired t-test and the ANOVA. RESULTS. The mean strain values (MSV) for the working sides were 151.83 ${\mu}{\varepsilon}$, 176.23 ${\mu}{\varepsilon}$, and 131.07 ${\mu}{\varepsilon}$ for Group I, Group II, and Group III, respectively. There was a significant difference between Group II and Group III (P < .05). Also, the MSV for non-working side were 58.29 ${\mu}{\varepsilon}$, 72.64 ${\mu}{\varepsilon}$, and 98.93 ${\mu}{\varepsilon}$ for Group I, Group II, and Group III, respectively. One was significantly different from the others with a 95% confidence interval (P < .05). CONCLUSION. The MSV for the working side of Groups I and II were significantly different from that for the non-working side (Group I: t = 7.58, Group II: t = 6.25). The MSV for the working side of Group II showed significantly larger than that of Group III (P < .01). Lastly, the MSV for the non-working side of Group III showed significantly larger than those of Group I or Group II (P < .01).

3차원 유한요소법에 의한 임플란트 지지 3본 고정성 가공 의치의 부적합도가 인접골 응력에 미치는 영향 분석 (Finite Element Analysis of Bone Stress Caused by Horizontal Misfit of Implant Supported Three-Unit Fixed Prosthodontics)

  • 이승환;조광헌
    • 구강회복응용과학지
    • /
    • 제28권2호
    • /
    • pp.147-161
    • /
    • 2012
  • 본 연구에서는 유한요소해석 방법을 사용하여 임플란트 지지 3본 고정성 가공 의치에 수평적인 부적합이 존재할 때 그 정도가 임플란트 인접골 응력 발생에 미치는 영향에 대해 조사하였다. 3본 고정성 가공의치, 임플란트/악골 복합체로 구성된 해석 모델은 3차원으로 연구되었다. 3본 고정성 가공의치의 체결 간격은 하악 제2 소구치와 제2 대구치에 17.9mm 거리로 식립된 임플란트 간격에 비해 0.1mm 짧거나(17.8mm), 0.1mm 길게(18.0mm) 모델링하였다. 3본 고정성 가공의치와 임플란트 지대주 간의 체결은 총 6단계로 모사되었고 각 단계별로 가공의치가 하방으로 0.1mm 씩 변위되었다. 유한요소해석에는 PC용으로 출시된 DEFORM$^{TM}$ 3D 프로그램(ver 6.1, SFTC, Columbus, OH, USA)을 사용하였다. 3본 고정성 가공의치와 임플란트 사이의 응력은 von-Mises 응력, 최대 압축 응력, 필요한 경우 방사상 응력을 평가하였다. d=18.0mm인 모델에서는 가공의치와 지대주간의 체결이 이루어지지 않은 반면, d=17.8mm 인 모델에서는 성공적으로 체결이 가능했다. 체결 여부를 떠나 과도하게 높은 응력이 체결과정과 그 이후에 발생되었는데, 17.8mm 모델의 경우 체결완료 후에도 임플란트 주위 변연골에서 잔류하는 인장 및 압축 응력이 각각 최대 186.9MPa과 114.1MPa이었다. 이 경우 임플란트로부터 2mm 떨어진 부분까지 압축 응력이 골개조 장애 임계 응력인 55MPa($4,000{\mu}{\varepsilon}$과 같은 크기)보다 크게 측정되었다. 3본 고정성 가공의치의 0.1mm 크기의 수평적 부적합은 체결 과정뿐만 아니라 완료 후에도 인접 변연골에 높은 응력을 발생시킬 수 있다.

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

상악 완전 무치악 환자의 CAD/CAM 을 이용한 임플란트 식립(NobelGuide$^{TM}$) 및 즉시하중 후 고정성 보철수복 증례 (Implant Supported Fixed Restoration for Maxillary Edentulism using CAD/CAM Guided Implant Surgery (NobelGuide$^{TM}$) and Immediate Loading)

  • 허윤혁;이양진;김대곤;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제28권4호
    • /
    • pp.423-439
    • /
    • 2012
  • NobelGuide$^{TM}$ 임플란트 시스템은 골량과 골질을 수술 전에 판단하여 점막을 젖히지 않고 미리 계획된 스텐트와 보철물을 이용하여 즉시하중을 부여하는 CAD/CAM 기반의 임플란트 보철 치료방법이다. 환자의 불편감을 최소화하여 미리 예측 가능한 위치에 임플란트를 식립함으로써 술 후 합병증 및 보철과정을 간소화 할 수 있는 장점이 있다. 본 증례의 환자는 56세 남성으로 상,하악 부분 무치악 상태였으며, 상악전치부 보철물 탈락과 하악 전치가 흔들린다는 주소로 내원하였다. 이에 상악 잔존치 모두와 하악 4전치 발거 및 치주치료를 실시한 뒤 임시 의치를 6개월간 사용하여 발치와 치유 및 의치 적응여부를 평가하였다. 골량은 충분하다고 판단되었고 환자의 협조도와 경제적인 여건, 전신건강 등 여러 사항이 양호하여 CAD/CAM 기반의 수술템플렛을 이용한 무판막 수술을 통해, 미리 제작된 임시 고정성 보철물로 즉시하중을 부여하는 상악 NobelGuide$^{TM}$ 임플란트 시스템을 계획하였다. 사용중인 임시의치를 이용하여 제작한 방사선 스텐트로 CT를 촬영하고, computer based planning (Procera$^{(R)}$ software)을 통해 3차원적인 골형상과 각 부위별 단면상을 참고하여 상악에 8개의 임플란트 식립체를 생역학적 관점 및 골조건을 고려하여 분산 배치하였다. 미리 제작된 임시 고정성 보철물을 임플란트 수술 후 즉시 장착 및 하중을 부여하여 기능하도록 하였으며 6개월 후 골유착 정도를 평가한 뒤 금속구조물을 이용한 최종 보철물을 제작하였다. 하악의 경우 전치부 도재전장주조금속관과 우측 구치부 임플란트 보철물 제작을 통해 상, 하악 치료를 마무리하였다.