Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

IMZ 임플란트의 장기적 성공률과 실패율 (Long-term Evaluation of IMZ Implants;Success and Survival Rates)

  • 박지은;김태균;정의원;김창성;최성호;조규성;김종관;채중규
    • Journal of Periodontal and Implant Science
    • /
    • 제35권4호
    • /
    • pp.1039-1052
    • /
    • 2005
  • IMZ는 "intramobile cylinder implant system" (IMZ)로 독일에서 가장 오래되고 많이 사용되어진 임플란트 중 하나이다. 이 임플란트에 관한 장기적 성공률과 생존률에 대한 연구는 대개 80% 이상을 보고하고 있다. 그러나, 연세대학교 치과병원 치주과에서 식립된 83개의 임플란트에서는 이전의 연구와는 다른 결과를 나타내었다. 1. IMZ 임플란트의 생존률은 67.5% 였다. 2. 변연 치조골 소실에 대한 성공 기준을 적용한 결과 성공률은 49.4%로 나타났다. 3. 발거된 총 27개의 임플란트 중에서 임플란트 주위 골소실을 가지는 경우는 17개, 내부구조 파절은 4개, 식립체 파절은 5개로 보고되었다. 4. 10년 이상 생존된 임플란트에서 변연골 소실의 평균치는 2.82mm였다. IMZ 임플란트는 장기적으로 높은 실패율을 보고하였다. 이는 cylindrical design, titanium plasma flame spray coating, prosthodontic complication 등의 요소에 기인한 것으로 사료된다. 임플란트는 그 형태, 표면 처리 등 여러 가지 요인들에 의해 실패가 나타날 수 있으며 본 연구를 통해 임플란트의 개발 및 선택에 바탕이 될 수 있을 것으로 생각된다.

Modified Pharmacokinetic/Pharmacodynamic model for electrically activated silver-titanium implant system

  • Tan, Zhuo;Orndorff, Paul E.;Shirwaiker, Rohan A.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권3호
    • /
    • pp.127-141
    • /
    • 2015
  • Silver-based systems activated by low intensity direct current continue to be investigated as an alternative antimicrobial for infection prophylaxis and treatment. However there has been limited research on the quantitative characterization of the antimicrobial efficacy of such systems. The objective of this study was to develop a semi-mechanistic pharmacokinetic/pharmacodynamic (PK/PD) model providing the quantitative relationship between the critical system parameters and the degree of antimicrobial efficacy. First, time-kill curves were experimentally established for a strain of Staphylococcus aureus in a nutrientrich fluid environment over 48 hours. Based on these curves, a modified PK/PD model was developed with two components: a growing silver-susceptible bacterial population and a depreciating bactericidal process. The test of goodness-of-fit showed that the model was robust and had good predictability ($R^2>0.7$). The model demonstrated that the current intensity was positively correlated to the initial killing rate and the bactericidal fatigue rate of the system while the anode surface area was negatively correlated to the fatigue rate. The model also allowed the determination of the effective range of these two parameters within which the system has significant antimicrobial efficacy. In conclusion, the modified PK/PD model successfully described bacterial growth and killing kinetics when the bacteria were exposed to the electrically activated silver-titanium implant system. This modeling approach as well as the model itself can also potentially contribute to the development of optimal design strategies for other similar antimicrobial systems.

다층 지르코니아를 이용한 임플란트 전치부 수복 증례 (Restoration of anterior teeth with dental implant using multilayer zirconia)

  • 이성희;이영후;홍성진;백장현;노관태;배아란;권긍록;김형섭
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.469-477
    • /
    • 2021
  • 상악 전치부 임플란트의 성공적인 수복을 위해서는 pink esthetics와 white esthetics가 모두 충족되어야 한다. Pink esthetics 부분의 경우 적절한 임시보철물의 역할이 중요하고, white esthetics 부분의 경우에는 최종 보철물의 색상과 형태가 중요하다. 다층 지르코니아는 기존의 단일구조 지르코니아에 비해 절단 부위의 투명도가 높기 때문에 추가적인 도재 축성 없이 자연스러운 보철물 제작이 가능하다. 따라서 본 증례에서는 상악 전치를 상실한 환자에서 적절한 임시보철물을 통해 기능과 심미성을 충분히 회복한 후 다층 지르코니아를 통해 white esthetics를 달성하였다.

Combination syndrome 예방을 고려한 flexible IARPD 증례 (Flexible IARPD considering the prevention of combination syndrome: a case report)

  • 김소연
    • 대한치과보철학회지
    • /
    • 제60권4호
    • /
    • pp.347-353
    • /
    • 2022
  • 상악 완전 무치악과 하악 양측 후방 무치악 상태의 환자에서 전통적인 의치를 제작하는 방법은 흔히 볼수 있는 치료 방법이다. 그러나 장기적으로 볼 때 이와 같은 구강내 환경에서는 복합증후군(Combination syndrome)이라는 합병증이 발생할 수 있다. 이때 임플란트를 동반한 국소의치(Implant Assisted Removable Partial Denture, IARPD)의 적용으로 치조골 보존과 함께 Combination syndrome의 예방을 도모할 수 있다. 본 증례에서는 무치악 부위에 임플란트의 추가 식립 시 국소의치의 움직임에 의해 최후방 지대치에 가해지는 응력을 줄일 수 있으므로 금속이 아닌 레진 클라스프를 계획하였고 flexible 의치 레진을 사용하였다. 상악 총의치, 하악 flexible IARPD를 계획하여 최소한의 비용과 수술로서 심미적, 기능적인 장기적 예후를 얻어 보고하고자 한다.

양극산화 임플란트 표면에 적용된 골형성단백질과 혈관내피세포성장인자가 골유착에 미치는 영향: 예비연구 (Combined effects of rhBMP-2 and rhVEGF coated onto implants on osseointegration: pilot study)

  • 허중보;윤미정;정창모;신상완;전영찬
    • 대한치과보철학회지
    • /
    • 제51권2호
    • /
    • pp.82-89
    • /
    • 2013
  • 연구 목적: 본 연구는 양극산화 임플란트에 골형성단백질과 혈관내피세포성장인자를 코팅한 임플란트를 토끼의 경골에 식립하여 골과 임플란트 계면의 골유착 향상의 가능성을 평가하고자 시행하였다. 연구 재료 및 방법: 6마리의 토끼 양측 경골에 코팅을 하지 않은 양극 산화 임플란트(대조군)와 골형성단백질과 혈관내피세포성장인자를 코팅한 임플란트(실험군)을 각각 한쪽에 2개씩 식립하였다, 토끼는 2주, 8주에 각각 3마리씩 희생하였고 전체 식립된 임플란트는 24개이었다. 각 시기별, 그룹별 임플란트 수는 각각 6개씩이었다. 임플란트안정지수(resonance frequency analysis (RFA)), 회전 제거력(Removable torque measurement (RTQ))을 희생 시기에 측정하였다. 독립표본 t-test (SPSS Ver. 15.0, Chicago, USA)을 이용하여 2주, 8주에서 대조군과 실험군의 차이를 비교 분석하고, 유의수준95%에서 통계적으로 검정하였다. 결과:대조군과 실험군 모두 8주에서 우수한 골유착을 보였다. 특히 실험군에서 8주에 ISQ, RTQ 값 모두 대조군과 비교하여 우수한 값을 나타내었다 (P<.05). 하지만 2주에서는 두군 사이에 통계적 유의성을 보이지 않았다(P>.05). 결론: 골형성 단백질과 혈관내피세포성장인자를 임플란트 표면에 코팅하여 식립하는 것은 치유의 후반기에 골유착을 증대하는 것으로 사료된다.

교정용 미니임플랜트의 이중 피치와 직경의 차이가 삽입 및 제거 토크에 미치는 영향 평가 (Effect of dual pitch mini-implant design and diameter of an orthodontic mini-implant on the insertion and removal torque)

  • 김종완;조일식;이신재;김태우;장영일
    • 대한치과교정학회지
    • /
    • 제36권4호
    • /
    • pp.275-283
    • /
    • 2006
  • 작은 크기의 교정용 미니임플랜트는 교정적 고정원으로 널리 이용되고 있다. 그러나 빈번히 탈락하는 단점이 있어 이를 개선하기 위해 안정성을 향상시키기 위한 다양한 연구가 시도되어 왔다. 이 연구의 목적은 이중 피치와 직경에 관련하여 미니임플랜트의 안정성에 대한 기계적 성질을 비교 분석하는 것이다. 미니임플랜트의 길이는 8 mm였으며, 피치는 단일 피치형과 이중 피치형, 직경은 1.4 mm와 1.6 mm로 단일 피치형 1.4 mm, 단일 피치형 1.6 mm, 이중 피치형 1.4 mm, 이중 피치형 1.6 mm 등 총 4군으로 구성되었다. 각 군은 20개의 미니임플랜트로 구성되었고, 균일한 밀도의 polyurethane foam에 삽입 후 제거하였다. 시간에 따른 삽입 및 제거 토크의 변화와 각각의 최대 토크 등을 측정하여 기계적 성질을 비교 분석하였다. 이중 피치형은 단일 피치형보다 유의성 있게 더 낮은 최대 삽입 토크와 더 큰 최대 제거 토크를 보여주었다. 직경 1.6 mm는 1.4 mm보다 유의성 있게 더 큰 최대 삽입 토크와 최대 제거 토크를 보여주었다. 이중 피치형 1.4 mm군은 삽입 시에는 유의성 있게 가장 낮은 최대 삽입 토크를 보여주었으며 제거 시에는 단일 피치형 1.6 mm군보다 높거나 비슷한 최대 제거 토크를 보여주었다. 특히, 이중 피치형군은 최대 제거 토크 후 지속적으로 높은 제거 토크를 보여주었다. 미니임플랜트의 기계적 안정성은 이중 피치에 의해 향상될 수 있으며, 상부의 미세 나사산은 작은 직경에서도 풀림 토크에 저항하는 기계적 안정성을 향상시킬 수 있을 것으로 보인다.

유도결합방식에 의한 무선 에너지 및 데이터 전송 (Wireless Energy and Data Transmission Using Inductive Coupling)

  • 이준하
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.42-48
    • /
    • 2008
  • 최근 첨단 과학의 발달과 함께 인체조직에 대한 적용도가 뛰어난 소재가 개발되어 초소형의 이식형 장치가 개선되어감에 따라 전력공급방법의 다양한 연구가 이루어져 유도코일을 이용하여 무선으로 전력을 전송하는 장치가 연구되어오고 있다. 이에 저자는 이론적으로 효율이 100%인 E급 전력증폭기를 사용하여 $2{\sim}30mm$의 공극거리에서 가장 이상적인 주파수를 1MHz로 설정하여 제작하였고, 직경 46mm의 송수신 코일을 이용하여 코일의 비정렬에 대한 전송율이 이격거리가 10mm일 때, 20% 감소되었다. PLL을 사용하여 주파수추적동조법으로 공극거리 15 mm 이내에서는 완만하게 20% 정도의 에너지 전송효율을 얻을 수 있었다. 또한 최적의 공진거리에서 50 mA 정도의 출력전류가 얻을 수 있다는 것은 초소형 전기 자극기와 같은 이식형 장치를 동작시키는데 구동 전력으로 가능하다는 것을 알 수 있었다.

  • PDF

3본 나사 유지형 임플란트 보철물의 고정 방식에 따른 임플란트 고정체 치경부에 발생하는 변형율 비교분석 (Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses)

  • 김상범;이두형;이청희
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.321-327
    • /
    • 2020
  • 목적: 본 연구의 목적은 3본 나사 유지형 임플란트 보철물의 나사 고정 방식에 따른 치경부에 발생하는 변형율을 측정하고 비교하기 위함이다. 재료 및 방법: 2가지 종류의 임플란트(외부연결방식, 내부연결방식)를 각각 2개씩 4개 임플란트 고정체 경부에 스트레인 게이지를 부착한 후, 각 종류의 아크릴릭 레진 모형 2개를 제작하였다. CAD-CAM을 이용하여 hex 및 nonhex 지대주를 제작하였고,(EH, ENH, IH& INH 군) 나사-시멘트 유지보철 개념으로 보철물을 비귀금속으로 제작하였다. 각 지대주를 10 Ncm 토크로 고정한 후, 보철물을 합착하였다. 나사를 3가지의 다른 방법으로 30 Ncm까지 고정한 다음, 5분 후 변형율을 측정한 후 평균비교 및 군간 상호작용을 평가하였다 (α = .05). 결과: 외부연결방식 군은 내부연결방식 군에 비하여 유의하게 낮은 변형율을 나타냈으며, EH군이 ENH군보다 유의하게 낮은 변형율을 나타내었으나 (P < .05), 나사 고정 방법에 따른 차이는 없었다 (P > .05). IH군이 INH군에 비하여 유의하게 높은 변형율을 나타내었으며 IH군에서만 나사 고정 방법에 따라서도 차이가 있었다 (P < .05). 결론: 나사 유지형 임플란트 보철물에서는 외부연결방식인 경우에는 큰 영향이 없으나, 내부연결방식에서는 보다 큰 변형율이 발생하고 나사 고정 방법도 영향을 주는 것으로 나타났다.