• 제목/요약/키워드: Impermeable type

검색결과 50건 처리시간 0.033초

투습방수의류의 보온력 및 증발저항 평가와 관련 변인 (An Evaluation of Factors Influencing the Thermal Insulation and Evaporative Resistance of a Waterproof and Breathable Garment System)

  • 심현섭
    • 한국지역사회생활과학회지
    • /
    • 제25권4호
    • /
    • pp.549-556
    • /
    • 2014
  • This study evaluates the thermal insulation and evaporative resistance of a waterproof and breathable garment system and determines the factors influencing its thermal performance. The experimental garments were composed of underwear (shirts with 100% wool and 100% polyester) and outerwear (jackets and pants with a vapor-permeable membrane and a vapor-impermeable membrane). Data on clothing insulation in a dry condition ($10^{\circ}C$) and a wet condition ($10^{\circ}C$, 40% R.H.), evaporative resistance ($34^{\circ}C$, 40% R.H., and $10^{\circ}C$, 40% R.H.), and microclimate vapor pressure were collected and analyzed. According to the results, the thermal insulation of the experimental garment system ranged 1.27~1.40 in the dry condition and 0.40~0.89 in the wet condition at $10^{\circ}C$. Evaporative resistance ranged $41{\sim}525m^2Pa/W$. A decrease in thermal insulation by wetting underwear ranged 31~67% in the cold condition ($10^{\circ}C$). The breathability of the outer garment influenced the decrease in thermal insulation by wetting. The type of underwear fiber influenced the decrease in thermal insulation only when it was used with breathable outerwear. The vapor-permeable outerwear sample with polyester underwear (P_Perm) showed a larger decrease in insulation than that with wool (W_Perm). The evaporative resistance of the vapor-permeable ensemble showed no effect of underwear in the warm condition ($34^{\circ}C$), but polyester underwear showed lower evaporative resistance than wool in the cold condition ($10^{\circ}C$). The vapor-impermeable ensemble showed no difference in evaporative resistance between polyester underwear and wool underwear in both conditions. Future research should consider various clothing ensemble combinations and environmental conditions and evaluate wear comfort by using human subjects.

사각격자체계 수치모델에서의 경사면 처리기법에 관하여 (On Reasonable Boundary Condition for Inclined Seabed/Structure in Case of the Numerical Model with Quadrilateral Mesh System)

  • 허동수;이우동;배기성
    • 대한토목학회논문집
    • /
    • 제28권5B호
    • /
    • pp.591-594
    • /
    • 2008
  • 본 연구에서는 사각격자체계를 이용하는 수치해석기법을 대상으로 격자내에 생성되는 경사면의 합리적인 처리 및 경계조건을 검토하기 위하여 사각격자내에 존재하는 불투과성 및 투과성구조물의 경사면에 대한 새로운 처리기법과 경계조건을 제안한 후, 파 구조물 해저지반/해빈의 상호간섭을 직접 해석할 수 있는 3D-수치모델(LES-WASS-3D; 허와 이, 2007)을 이용하여 수치계산을 실시하였다. 이로부터 얻어진 계산결과와 종래의 계단식 격자구성을 이용한 수치해석결과를 비교 검토하여 제안한 사각격자내의 경사면 처리기법에 대한 타당성을 검증하였다.

Experimental study on improving bamboo concrete bond strength

  • Mali, Pankaj R.;Datta, Debarati
    • Advances in concrete construction
    • /
    • 제7권3호
    • /
    • pp.191-201
    • /
    • 2019
  • Bamboo concrete bond behaviour is investigated through pullout test in this work. The bamboo strip to be used as reinforcement inside concrete is first treated with chemical adhesive to make the bamboo surface impermeable. Various surface coatings are explored to understand their water repellant properties. The chemical action at the bamboo concrete interface is studied through different chemical coatings, sand blasting, and steel wire wrapping treatment. Whereas mechanical action at the bamboo concrete interface is studied by developing mechanical interlock. The result of pullout tests revealed a unique combination of surface treatment and grooved bamboo profile. This combination of surface treatment and a grooved bamboo profile together enhances the strength of bond. Performance of a newly developed grooved bamboo strip is verified against equivalent plain rectangular bamboo strip. The test results show that the proposed grooved bamboo reinforcement, when treated, shows highest bond strength compared to treated plain, untreated plain and untreated grooved bamboo reinforcement. Also, it is observed that bond strength is majorly influenced by the type of surface treatment, size and spacing of groove. The changes in bamboo-concrete bond behavior are observed during the experimentation.

사석방파제에 의한 파랑변형에 관한 연구 (Wave Transformation of a Rubble-Mound Breakwater)

  • 강인식;곽기석;김도삼;양윤모
    • 한국항만학회지
    • /
    • 제8권2호
    • /
    • pp.57-65
    • /
    • 1994
  • A theoretical formulation is performed to investigate the wave reflection and transmission ratios by a submerged multi-layered rubble-mound breakwater. This theory, which is based on the linear boundary integral method, can be extended to the multi-layered breakwater with arbitrary cross section. In the theoretical analysis evanescent mode wave is not considered, since fictitious open boundaries are put on the places far from the structure. Therefore the mathematical presentation may be simpler, and computational time shorter. The validity of obtained numerical results is demonstrated by comparing with ones of impermeable and permeable breakwaters. Comparison shows resonable agreement. On the basis of these verifications this theory is applied to the one and two-layered submerged rubble-mound breakwater with trapezoidal type.

  • PDF

연직차수벽에서 필터케익을 고려한 순간 변위시험 해석방법 (Slug Test Analysis in Vertical Cutoff Walls with Consideration of Filter Cake)

  • 웽테바오;이철호;최항석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.220-228
    • /
    • 2008
  • In constructing a slurry trench cutoff wall, a thin but relatively impermeable layer called filter cake can be formed on the excavation surface. The filter cake significantly influences the result of slug test analysis in the cutoff wall. This study is to examine the effect of filter cake on evaluating in situ hydraulic conductivity of the vertical cutoff wall along with slug test analyses. The numerical program Slug_3D was modified to take filter cake into account in the slug test simulation. With consideration of filter cake, the type curve method and the modified line-fitting method were used to reanalyze the case study taken from a landfill site. The previous results achieved by Choi and Daniel (2006b) without consideration of filter cake have been compared with the results in this study. The considerable difference between the two results shows the necessity of considering the filter cake in practice.

  • PDF

서울 강남지역 아파트단지의 녹지면적에 따른 온도변화 모형 (Variation Profiles of Temperature by Green Area of Apartments in Gangnam, Seoul)

  • 홍석환;이경재
    • 한국환경생태학회지
    • /
    • 제18권1호
    • /
    • pp.53-60
    • /
    • 2004
  • 아파트단지 내부녹지가 온도변화에 미치는 영향을 파악하고자 서울시 서초구, 강남구, 송파구 등 한강 이남지역에 위치한 아파트단지중 36개 지역을 대상으로 연구를 수행하였다. 아파트단지 내부온도는 Landsat ETM+영상 2scene을 분석하여 추정하였으며 온도변화 영 향요인으로는 토양피복유형과 건물밀도, 식생활력도로 구분하였다. 토양피복유형과 아파트단지내 온도와의 상관관계 분석결과 녹지율은 음(-)의 상관관계를, 불투수포장율은 양(+)의 상관관계를 보였으며 건폐율은 유의성이 인정되지 않았다. 투수포장지를 녹지면적과 불투수포장면적에 각각 합산한 값과 온도값의 상관관계 분석결과 투수포장면적을 불투수포장면적에 합산하여 산출한 상관계수보다 녹지면적에 합산하는 것이 상관계수가 보다 높게 나타나 투수포장지역도 녹지지역과 함께 도시온도를 낮추는 요소로 작용하는 것으로 판단되었다. 건물밀도의 요소로 선정한 용적율은 온도값과 유의성이 없었으며 NDVl는 값이 높을수록 온도가 낮았다. 아파트단지내 온도분포모형 구축을 위해 투수+녹지율, 녹지율, 건폐율, NDVI값을 독립변수로, 대상지온도를 종속변수로 한 회귀분석 결과 두 시기 영상 모두 독립변수 중 투수+녹지율만이 회귀식에 채택되었으며 회귀식의 수정 결정 계수($R^2$)는 각각 41.4(2000년 9월)와 40.4(2001년 6월)이었다.

도시 비오톱의 경관생태학적 특성분석 - 대구광역시를 사례로 - (Ecological Landscape Characteristics in Urban Biotopes - The Case of Metropolitan Daegu -)

  • 나정화;이정민
    • 한국조경학회지
    • /
    • 제30권6호
    • /
    • pp.128-140
    • /
    • 2003
  • The purpose of this research was to present characteristics for the classification of biotopes and classification method of biotopes as basic data for ecological landscape planning in Metropolitan Daegu. The results of this study were as follows. 1) The study identified fifteen characteristics for classification of biotopes. Ecological landscape characteristics were divided into structural and functional factors. There are six structural factors such an inclination, and nine functional factors such as temperature. 2) The study area was separated into sixty eight biotope types. For example, an industrial district was divided into two biotope types: a biotope type of an industrial district with abundant green space, and a biotope type of an industrial district with scarce green space. 3) In the result of cluster analysis using the average linkage method between groups, biotope groups were divided into fifteen clusters and biotope groups were divided into seven clusters. Each cluster was named according to the features of a descriptive statistics analysis. For example, cluster 8 was identified as a biotope type with an impermeable pavement rate of more than 90 percent and an afforestation rate under 10 percent. 4) Fifteen biotope groups were converted to land use patterns for remote application and utilization of urban biotope in city planning. Biotope groups of a building area beyond an intermediate floor with an afforestation rate under 20-30 percent was converted to a land use pattern such as a tall apartment complex or commercial district. When examining the characteristics that were established in this research, there was a limit to achieve the objective of grade-classification because of a lack of related basic data. The research of landscape ecological characteristics for the classification of biotopes could not be completed due to a lack of time and resources, thus the study of ecological landscape characteristics will be accomplished over time.

저부하형 개발을 위한 화단형 빗물침투시설 적용방안 - 생태전원마을에서의 적용을 중심으로 - (Application of the Flowerbed Type Infiltration System for Low Impact Development - Focus on the Application to Eco-Village -)

  • 한영해;이태구
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.33-40
    • /
    • 2012
  • Since 2000 country region developmental policy has been to integrate not only the improvement of physical living environment but also various subjects on ecology, environment, scenery, local culture, and green tourism. This study has recently established a decentralized Rainwater Management plan in order to provide an hydrology cycle system to the eco-village being planned by Seocheon-gun as a part of the garden village development business promoted by the ministry of agriculture and forestry. Hydraulic conductivity of the subject area is measured at $10^{-7}{\sim}10^{-10}m/sec$, and a flowerbed-type rainwater Infiltration system capable of controlling a non-point pollution source that stems from the development-caused impermeable surface has been applied. In the case of rainwater flowing out from the main entrance way and parking lot within the complex being treated in the flowerbed-type rainwater infiltration system, natural purification effects via soil and plants as well as natural water cycling effects through evaportranspiration and infiltration are expected. The significance of this study, compared to conventional decentralized rainwater management being applied limited to the urban areas, is that it offers appropriate rainwater management planning based on the analysis of the current situation of the subject area. Decentralized Rainwater Management is a valuable measure both economically and ecologically that reduces the burdens on local underground water cultivation as well as rain water pipe lines or purification systems, and sewage pipes.

열수지를 활용한 서울시 열환경 개선을 위한 공간 유형화 (Spatial Typification based on Heat Balance for Improving Thermal Environment in Seoul)

  • 권유진;안새결;이동근;윤은주;성선용;이기승
    • 국토계획
    • /
    • 제53권7호
    • /
    • pp.109-126
    • /
    • 2018
  • The purpose of this study is to identify the spatial types for thermal environment improvement considering heat flux and its spatial context through empirical orthodox formulas. First, k-means clustering was used to classify values of three kinds of heat flux - latent, sensible and storage heat. Next, from the k-means clustering, we defined a type of thermal environment (type LHL) where improvement is needed for more comfortable and pleasant thermal environment in the city, among the eight types. Lastly, we compared and analyzed the characteristics of each classified thermal environmental types based on land cover types. From the study, we found that the ratio of impervious surfaces, roads, and buildings of the type LHL is higher than those of the type HLH (relatively thermal comfort environment). In order to improve the thermal environment, the following contents are proposed to urban planners and designers depending on the results of the study. a) Increase the green zone rate by 10% to reduce sensible heat; b) Reduce the percentage of impermeable surfaces and roads by 10% ; c) Latent heat increases when water and green spaces are expanded. This study will help to establish a minimum criterion for a land cover rate for the improvement of the urban thermal environment and a standard index for the thermal environmental improvement can be derived.

Design and Construction of the Cylindrical Slit Type Shore Structures

  • Lee, Joong-Woo;Nam, Ki-Dae;Park, Sang-Gill;Kim, Sug-Moon;Kang, Seok-Jin
    • 한국항해항만학회지
    • /
    • 제33권9호
    • /
    • pp.645-651
    • /
    • 2009
  • In this study, a series of laboratory experiments were carried out to investigate the weak reflection of regular and random water waves over a train of protruded permeable shore structures. A cylindrical slit type breakwater and the alternatives are employed and compared for reflecting and transmitting capabilities of incident waves including wave forces. A series of random waves were generated by using the Bretschneider-Mitsuyasu frequency and directional spectrum. Measured spectrum of irregular waves without breakwaters is verified by comparing with those of the input waves generated. Weak reflection is occurred at the breakwater center of the peak frequency. If the row of breakwaters is fixed at three layers and the relative height of breakwater is fixed at 0.6, around 45% of incident wave energy is reflected to offshore. It is also found that the transmission of directional random waves increases as the maximum frequency parameter increases. A very good agreement is observed. Reflection coefficients of permeable submerged breakwaters are less than those of impermeable breakwaters. The upside-down L shape is recommended for a small fishery harbor mooring in terms of reflecting capability and of practical application. The final design was applied to the wharf of a small beach of Seolly, near Namhae at the southeast coast of Korea.