• Title/Summary/Keyword: Impeller Shape

Search Result 161, Processing Time 0.024 seconds

Numerical study on the Performance Improvement of the Sirocco Fan in a Range Hood (레인지 후드용 시로코 홴의 성능 향상을 위한 연구)

  • Park, Sang-Tae;Choi, Young-Seok;Park, Moon-Soo;Kim, Cheol-Ho;Kwon, Oh-Myoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.572-577
    • /
    • 2004
  • This paper presents numerical study on the performance improvement of the sirocco fan in a range hood. The performance of sirocco fan means a higher flowrate, a higher static pressure and a lower required motor power in a fixed geometry constraint. Various impeller geometric parameters, such as blade profile, blade diameter, blade thickness profile and blade exit angle, were investigated by numerically and the results were compared with each other to know the effects on the performance. In this approach, the volute geometry were fixed with the original shape. The numerical results show that the blade profile with airfoil shape and small exit blade thickness increases the performance. The blade exit angle shows optimum angle within a varied range. The efficiency of the optimized exit angle was about $10\%$ higher than the base blade exit angle and the static pressure was about $28\%$ higher at the flow coefficient 0.22.

  • PDF

Study on Power Measurement and Comparison of Marine Current Turbine in a Towing Tank (예인수조를 이용한 조류발전 터빈의 동력 계측 및 비교 연구)

  • Do, In-Rok;Kim, Moon-Chan;Lee, Seung-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.4
    • /
    • pp.230-238
    • /
    • 2011
  • The experimental study for the performances of 100 kW marine current turbines (Horizontal Axis Turbine) has been conducted with three cases of 700 mm diameter model in PNU 100 m towing tank. Three cases of impeller have been designed according to the variation of section configuration and tip shape. The model tests have been carried out at different speed of revolution to find out the scale effect (Reynolds number effect). The designed rake impeller was the best among them in the efficiency point of view especially at high Tip Speed Ratio (TSR). The present study is expected to be extended to conduct at high reynolds number as well as the computational study for the validation.

Experimental Investigation on the Hydraulic Performance of the Regenerative Pump According to the Blade Angle (재생 펌프의 날개 각도에 따른 성능 변화에 관한 실험적 연구)

  • Yoo, Il Su;Choi, Won Chul;Park, Mu Ryong;Lee, Gong Hoon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.5-10
    • /
    • 2013
  • The regenerative pump is a kind of turbomachine which is capable of developing high pressure rise at relatively lower flow rates compared to the centrifugal and axial pumps. Although the efficiency of regenerative pumps is much lower than other turbomachines, still they have been widely used in many industrial applications for working at low specific speeds. There are some theoretical models to analysis the pump performance, however, the effect of the blade angle on the pump performance has not been covered in any model to date. In the present study, experimental study on the regenerative pump performance according to the impeller blade angle and its shape has been carried out. The straight radial blades with forward, backward and chevron blades which have inclined angles of $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ were tested. The pump performance characteristics as the pressure head, efficiency were obtained depending on the flow rate for every impeller, and their results, expressed in appropriate non-dimensional coefficients, were compared and analysed in detail. From the experimental results, it was found that the pressure head and the efficiency depend strongly on the blade angles as well as the blade type. These experimental data has made it possible to better understand the effects of the blade angle on the pump performance, and widen the applicability of the current performance analysis and design models with including the effect of blade angles.

Investigation of Local Flow Parameters Caused by Flow Acceleration Corrosion Downstream of an Orifice in a Piping System (배관계 오리피스 하류에서 유동가속부식으로 인한 국소 유동 파라미터에 대한 조사)

  • Kim, Kyung-Hoon;Cho, Yun-Su;Kim, Hyung-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.377-385
    • /
    • 2013
  • In this study, the performance of an impeller according to blade length and pitch angle was studied experimentally by building a variable pitch impeller while changing blade length to review the effect of blade length and pitch angle on a fan's performance. The pitch angle was changed in six steps from $20^{\circ}{\sim}45^{\circ}$ at intervals of $5^{\circ}$ while the blade lengths were changed to 90 mm, 100 mm, 110 mm and 120 mm with an identical airfoil shape while carrying out the experiment. The results are summarized as follows : The air flow per static pressure of axial fans increased linearly with increase of pitch angle, but the high static pressure showed a decrease at a pitch angle of $35^{\circ}$. The shaft power increased proportionally to the pitch angle at all blade lengths; the larger the pitch angle, the larger the measured increase of shaft power. This is because the drag at the fan's front increases with the pitch angle. In the axial fans considered in this research, the flow and incre.

Effects of Impeller Shape of Submersible Nonclogging Pump on its Performance (비 막힘형 수중 펌프 임펠러 형상이 펌프 성능에 미치는 영향)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1201-1207
    • /
    • 2012
  • This study was performed to develop a high-efficiency submersible nonclogging pump impeller. Toward this end, we simulated the effect of some parameters such as the outlet position of a blade ($h_I$), outlet width of a blade ($b_2$), and hub profile on the pump efficiency by using the commercial codes ANSYS CFX and BladeGen. The results showed that the pump efficiency was proportional up to $h_I$= 38 mm and $b_2$= 55 mm. It remained constant over these values. However, the head and shaft power were proportional to $h_I$ and $b_2$ in the simulated ranges. The effects of hub profile changes on the pump efficiency were relatively small compared to those of the other parameters.

A study on the vaneless diffuser and volute casing design for the improvement of small centrifugal compressors (소형 원심 압축기의 성능 향상을 위한 베인 없는 디퓨저와 볼류트 케이싱의 설계에 관한 연구)

  • Jo, Jae Phil;Paek, Seung Yun;Kim, Sung Don;Ahn, Kyubok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3722-3730
    • /
    • 2015
  • The performance improvement of a small centrifugal compressor for waste water treatment has been conducted by the design change of vaneless diffuser and volute casing. Existing two compressors use a common impeller, but the width and length of the vaneless diffuser and the cross-sectional shape of the volute casing are different, respectively. Based on the experiment of the existing two compressors and their CFD results, the design of the vaneless diffuser and the volute casing has been changed. It was found that the strength of the interaction among the volute tongues, the vaneless diffusers and the impellers of two existing/one improved compressors, was affected by the cross-sectional area and inlet radial length of the volute casing including system losses' change. The efficiency of the impeller with one existing design was increased as the decrease of the width of the vaneless diffuser, but losses at the diffuser were accumulated. In conclusion, approximately 2.88%p efficiency increase at the design point of the new compressor with the improved design has been confirmed by CFD analysis results.

A Study on the EDT Characteristics of TM Work Roll and Variation of Strip Surface Roughness

  • Kim, Soon-Kyung;Moon-Kyung, Kim
    • KSTLE International Journal
    • /
    • v.2 no.2
    • /
    • pp.133-137
    • /
    • 2001
  • This paper investigates the correlation between strip surface roughness and the surface of the work roll. As the actual temper mill(TM) is used, this data will be adopted to another actual temper mill for the application and operation of this experiment. Conclusions are as follows: Electro-discharge texturing(EDT) roll has homogeneous roughness distribution and shape, and also a sinuous peak surface and the life is 2 times longer than that of shot blast texturing(SBT) method. And the higher surface roughness of work roll, the more time is necessary at the EDT method. In the SBT method without the correlation of roughness, but impeller rotation speed with an uncontrollable peak count. The roughness of SBT roll is irregularity compared to that of EDT roll because the work roll roughness is transferred to the strip which was temper rolled, and produces a more desirable image and greater clarity to the color painted steel sheet.

  • PDF

Study on Optimization of Aerodynamic Design of A Jet Fan (제트송풍기의 공력설계 최적화에 관한 연구)

  • Seo, Seoung-Jin;Kim, Kwang-Yong;Chang, Dong-Wook
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.439-443
    • /
    • 2002
  • In this study, three-dimensional incompressible viscous flow analysis and optimization using response surface method are presented for the design of a jet fan. Steady, incompressible, three-dimensional Reynolds averaged Wavier-Stokes equations are used as governing equations, and standard k-$\epsilon$ turbulence model is chosen as a turbulence model. Governing equations are discretized using finite volume method. Sweep angles and maximum thickness of blade are used as design variables for the shape optimization of the impeller in response surface method. The experimental points which are needed to construct response surface are obtained from the D-optimal design and Full Factorial design and relations between design variables and response surface are examined.

  • PDF

Prediction of Axial Pump Performance Using CFD Analysis (전산유체해석을 이용한 축류펌프의 성능예측)

  • Kim M. H.;Kim J. I.;Park J. S.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.14-20
    • /
    • 2001
  • The CFD analysis of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump was performed. Not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicted the experimental head value. In the range of the higher flow rates, the results were also in very good agreement with the experimental data, not only in absolute value but also in term of slope. Although experimental data to be compared were not available in the range of the lower flow rates, the results well described the S-shape performance curve of the axial pump characteristic.

  • PDF

Reliability Evaluation of a Slurry Pump (슬러리 펌프의 신뢰성 향상)

  • Jung, Dong Soo
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.263-271
    • /
    • 2016
  • Purpose: A slurry pump for flue gas desulfurization system performs a role that discharges the slurry of a plaster shape in a thermal power plant. Since a slurry pump transfers the slurry by the centrifugal force, it has the friction wear in the impeller and liner because of the slurry. Methods: In this study, failure analysis and test evaluation on the slurry pump have been proposed and the process that reliability of the product improves through design improvement has been presented. And failure cause of typical failure case has been investigated and improvement design has been presented. Results: Reliability improvement is established by analysis of the test results of before and after acceleration test. Conclusion: This study can be provided to improve the product reliability through failure analysis of a slurry pump.