• Title/Summary/Keyword: Impedance Method

검색결과 2,202건 처리시간 0.039초

임피던스 성분을 이용한 매입형 영구자석 전동기의 고정자 절연파괴 고장의 초기 검출 기법 (Early Detection Technique in IPM-type Motor with Stator-Turn Fault using Impedance Parameter)

  • 정채림;김경태;허진
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.612-619
    • /
    • 2013
  • This paper proposes an early diagnosis technique for the stator-turn fault (STF) in an interior permanent magnet (IPM)-type brushless DC (BLDC) motor using the impedance parameter. We have analyzed the varying characteristics owing to the STF through various experiments and the finite element method (FEM). As a result, we have presented a simple method for fault detection. This technique can be applied without requiring a fast Fourier transform (FFT) and the calculation of the negative-sequence impedance. The fault detection system works on the basis of the comparison the measured impedance with the database impedance. The variations in the characteristics owing to the STF as well as the proposed technique have been verified through the simulation and experiment.

임피던스 위상각제어를 적용한 초음파모터의 구동을 위한 새로운 제어방식에 대한 연구 (A Study on the Novel Control Method to Drive the Traveling Wave Type Ultrasonic Motor adapting the Impedance Angle Control)

  • 이을재;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권6호
    • /
    • pp.450-456
    • /
    • 2000
  • In this paper, we proposed a novel control method which uses the internal impedance angles as a control parameter to drive traveling wave type ultrasonic motor. An impedance characteristic of the ultrasonic motor is obtained by analysis of the equivalent circuits including the external inductor used to generate the coupled resonance. The phase angle of internal impedance to achieve optimal control performance is derived. For the tracking of impedance angle, an information of phase difference is obtained from the applied voltage and current. The high speed phase difference detector is designed to monitor the phases of ultrasonic motor. The effectiveness of the proposed control scheme is clarified by experiments.

  • PDF

IQ 복조 기법을 이용한 광대역 접지 임피던스 측정기의 설계 및 구현 (Design and Implementation of Wideband Grounding Impedance Measurement Device using IQ Demodulation Method)

  • 김영진;길형준;김성주;김재형
    • 한국안전학회지
    • /
    • 제31권6호
    • /
    • pp.19-24
    • /
    • 2016
  • One of key parameters on lightning protection system design of electric, information and communication system is grounding impedance. Earth impedance includes numerous information about earthing performance of grounding system. This paper suggests grounding impedance measuring device which is comprised of wideband current source, voltage and current measuring components. We used IQ Demodulation to measure more accurate phase difference of voltage and current. The range of frequency is up to 1 MHz that is IEEE defined as the range of lightning surge. We compared developed grounding impedance measuring device with existing one to test its performance, and we used grounding system while we implemented measurement and analysing by using fall of potential method IEEE Std.81 proposed.

다중 다공판 시스템의 음향임피던스와 계산모델에 관한 고찰 (An Investigation on the Acoustic Impedances and Estimation Models of Multiple Layer Perforated Plate Systems)

  • 이동훈;허성춘;허성욱;김민배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1238-1243
    • /
    • 2002
  • In this study, the validity of the acoustic impedance model and the estimation model by electro-acoustic analogy suggested by Maa for predicting the absorptive performance of multiple layer perforated plate systems is investigated. From the comparison between the experiment and calculation for the absorption performance of double layer perforated plate system, the calculated results of using Rao and Munjal's impedance model and transfer matrix method are closer to the experimental values than those of using Maa's impedance model and electro-acoustic analogy. Therefore, in order to apply the acoustic impedance model and the estimation model by electro-acoustic analogy suggested by Maa to the multiple layer perforated plate systems, it is necessary that the suggested acoustic impedance and estimation models should be re-examined.

  • PDF

한의학적 활용을 위한 임피던스 심장기록법의 연구동향 (A Review on Impedance Cardiography and Its Oriental Medical Application)

  • 고영일;이현수;박영재;박영배
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.67-78
    • /
    • 2006
  • Objectives : To review the method, validity and reliability of Impedance Cardiography and to study its oriental medical application. Method : The papers reviewed in this study were searched through internet search engines such as Springer, Science Direct, and China National Knowledge Infrastructure. Conclusion : In this study, the methodological limitations, validity and reliability of impedance cardiography were examined. Impedance Cardiography is recognized as a highly accurate non-invasive tool to assess hemodynamic parameters. The ability of impedance cardiography to assess hemodynamic parameters in non-invasive way is very suitable for researches on the effect of oriental medical therapeutics or the validation of oriental medical diagnostic.

  • PDF

임피던스 방식의 동작분석을 위한 최적전극 선정 (Optimal Electrode Displacement for Motion Analysis using Bio-impedance)

  • 송철규;변용훈;윤대영;이명권;김거식;송창훈;김경섭;김수찬;김덕원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2887-2890
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh, knee, and foot, and two potential electrodes are applied to the lateral, medial, and posterior position of lower leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for ankle, knee and hipjoint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements -0.87, 0.957 and 0.80. respectively. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed possibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

  • PDF

Impedance-based damage monitoring of steel column connection: numerical simulation

  • Ho, Duc-Duy;Ngo, Thanh-Mong;Kim, Jeong-Tae
    • Structural Monitoring and Maintenance
    • /
    • 제1권3호
    • /
    • pp.339-356
    • /
    • 2014
  • This study has been motivated to evaluate the practicality of numerical simulation of impedance monitoring for damage detection in steel column connection. In order to achieve the objective, the following approaches are implemented. Firstly, the theory of electro-mechanical (E/M) impedance responses and impedance-based damage monitoring method are outlined. Secondly, the feasibility of numerical simulation of impedance monitoring is verified for several pre-published experimental examples on steel beams, cracked aluminum beams, and aluminum round plates. Undamaged and damaged steel and aluminum beams are simulated to compare to experimental impedance responses. An aluminum round plate with PZT patch in center is simulated to investigate sensitive range of impedance responses. Finally, numerical simulation of the impedance-based damage monitoring is performed for a steel column connection in which connection bolts are damaged. From the numerical simulation test, the applicability of the impedance-based monitoring to the target steel column connection can be evaluated.

임피던스 파라미터의 자기 조절 기능을 갖는 위치 기반 임피던스 제어기의 설계 및 적용 (A Design and Implementation of Position Based Impedance Controller with Self-Adjusted Impedance Parameters)

  • 황인호;박영칠
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.410-410
    • /
    • 2000
  • Impedance control is recognised as one of the most proper control scheme to carry out the assembly tasks, since it can control the dynamic relationship between the manipulator and environment directly. However, it is well known that the contact force cannot be controlled directly using the impedance control. Also impedance parameters should be properly defined depending on the task to be performed. We propose a new position based impedance control, which has self-adjusted impedance parameters and can control the contact force explicitly, Impedance parameters, as time-varying parameters, are adjusted automatically based on the measured contact force and the position error during the task. A proposed algorithm was implemented on the peg-in-hole task with the industrial manipulator. We shows the effectiveness of proposed control method experimentally.

  • PDF

옥내 전력선 통신 채널 임피던스 측정 장치 설계 (Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications)

  • 허윤석
    • 정보학연구
    • /
    • 제8권3호
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

웨이브릿 기법을 이용한 리커시브 실시간 고장점 표정 시스템 연구 (Recursive Real Time Fault Locator with Wavelet Method)

  • 이성우;하복남
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1522-1530
    • /
    • 2008
  • This paper presents a discrete wavelet analysis based algorithm to address the fault impedance calculation under transient state in radial power distribution networks. The fault impedances have been derived under different fault conditions. Furthermore, a recursive fault distance estimation method is proposed utilizing the measured fault impedance and power line parameters. The proposed scheme can resolve the errors caused by the non-homogeneous power lines, the presence of lateral loads since, the fault impedance will always be updated with the recursive form. For the verification of the proposed scheme, a filed test has been peformed with varying fault resistances in the 22.9(kV) radial system. Power meters and fault locators were installed at the substation. It was figured out that the performance of the discrete wavelet and the recursive scheme are very good even for high fault resistance condition.