• Title/Summary/Keyword: Impact level criteria

Search Result 180, Processing Time 0.024 seconds

The Current State of and Barriers to Quality Measurement, and Quality Managers' Reported Evaluation on Quality Indicators in Korea (국내 질 향상부서 중심의 질 지표 측정 현황, 장애요인과 평가)

  • Hwang Jee-In
    • Health Policy and Management
    • /
    • v.15 no.4
    • /
    • pp.26-45
    • /
    • 2005
  • The purposes of this study were to Identify the .level of measurement on quality Indicators and evaluate the existing indicators in order to determine the priority of quality indicators' application in Korean general hospitals. A survey was conducted using a questionnaire. The subjects were quality managers working at general hospital having over 300 beds. The criteria were relevance, reliability, precision, impact, application, and preference to evaluate quality indicators. According to these six criteria, each indicator was evaluated on a five point scale(5: excellent, 1: poor). The response rate was $40.4\%$. The hospitals have monitored the average of 3.8 indicators(median 4). The indicators such as return to operating room, unplanned readmission, cancellation of booked operations, death, hospital infection, cesarean section rate, volume per disease or procedure, readmission, re-operation, blood transfusion, and post-procedural complications were frequently measured. The top ten quality indicators in the evaluation by its relevance, validity, reliability, impact, preference and application were decubitus ulcer, clean wound infection, fall, unplanned return to operation room, transfusion reactions, foreign body left In during procedure, unplanned readmission, wound infection after contaminated surgery, postoperative hemorrhage/hematoma, and cesarean section rate in order. The high priority quality indicators frequently measured could be used as primary national indicators. Standardized guidelines about monitoring indicators and the utilization will preliminarily be needed to compare and reuse the data for various purposes and improve the quality of care continuously.

Assessment on the Possibility of Increase of SB5-B Small Car Impact Velocity (SB5-B 소형차 충돌속도의 상향 가능성 평가)

  • Kim, Kee-Dong;Ko, Man-Gi;Joo, Jae-Woong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.3013-3022
    • /
    • 2013
  • Satisfying the large car impact condition of the high level SB5-B for "SMART Highway" longitudinal barriers, the possibility of increase of the small car impact velocity from 120km/h to 130km/h was investigated. Through computer simulation using input parameters calibrated to full-scale crash test results, various longitudinal semi-rigid barrier models were improved such that for the small car impact speed of 120km/h the change of longitudinal and transverse velocities of the impact vehicle can satisfy the THIV limit. The barrier model determined through this process satisfied the performance assessment criteria for SB5-B impact conditions. Varying the wing angle of slip block-outs of the passed barrier model, the possibility of increase of the small car impact velocity was investigated by FEA and a full-scale crash test was conducted. It has been shown that the possibility to increase the small car impact speed to 130km/h is high if the test facility condition for 130km/h impact velocity is better equipped.

An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation (완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구)

  • Ahn, Jae-Won;Jun, Myoung-Hoon;Lee, Bum-Sik;Lee, Do-Heun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF

Standardization of Stiffness Test Method of Non-bearing Lightweight Wall for building (건축용 비내력 경량벽체의 정적 수평하중저항성 시험방법의 표준화)

  • Kim, Jin-Sik;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.185-186
    • /
    • 2015
  • The use of non-bearing lightweight wall has increased recently due to the increase of high-rise buildings and supply of long-life housing. Lightweight wall has advantages such as reducing the self-weight of the building, convenience in installation, and shortening construction period, however, must have a sufficient strength to external force. This study standardized the stiffness (static horizontal load resistance) test method for lightweight walls by using the actual impact load obtained through the load analysis test conducted in the previous studies. The size of specimen was set up as height 2.4m and width 3.0m. Test apparatus and test methods were referred to BS 5234-2:1992. However, the loading level applied to the specimen was divided into 3 steps (3000N, 1000N, 500N) that can be applied selectively depending on the purpose of the wall. The deformation characteristics according to the same loading level were vary depending on the specimen's type, and the evaluation criteria for functional damage may vary depending on the material, method of construction, and purpose of wall. Therefore, we did not suggest unified evaluation criteria of the stiffness to the test results.

  • PDF

Noise Test of High Speed Train along Test Track (경부고속전철 시험선구간에서 소음영향 시험평가)

  • 나희승;김선우;김정태;정성수;조대승;김준엽
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1104-1109
    • /
    • 2002
  • High speed railroad noise is one of the main causes of environmental impact. An estimate of the relevant noise levels is usually required in order to evaluate the noise barrier and the anti-noise trailer. This paper introduce the test procedure and the estimate for HST noise. The aim of this is to measure, by means of a test, the level of acoustic pressure present during the passing of a KTX(Korea Train Express), in order to satisfy the contractual requirements and the noise criteria. A number of measurements are carried out in order to estimate noise impact by HST along test track.

  • PDF

Investigation of Damping Ratio of Steel Plate Concrete (SC) Shear Wall by Lateral Loading Test & Impact Test (횡방향 가력실험 및 충격실험을 통한 강판콘크리트(SC) 전단벽의 감쇠비 평가)

  • Cho, Sung Gook;So, Gi Hwan;Park, Woong Ki
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.79-88
    • /
    • 2013
  • Steel plate concrete (SC) composite structure is now being recognized as a promising technology applicable to nuclear power plants as it is faster and suitable for modular construction. It is required to identify its dynamic characteristics prior to perform the seismic design of the SC structure. Particularly, the damping ratio of the structure is one of the critical design factors to control the dynamic response of structure. This paper compares the criteria for the damping ratios of each type of structures which are prescribed in the regulatory guide for the nuclear power plant. In order to identify the damping ratio of SC shear wall, this study made SC wall specimens and conducted experiments by cyclic lateral load tests and vibration tests with impact hammer. During the lateral loading test, SC wall specimens exhibited large ductile capacities with increasing amplitude of loading due to the confinement effects by the steel plate and the damping ratios increased until failure. The experimental results show that the damping ratios increased from about 6% to about 20% by increasing the load from the safe shutdown earthquake level to the ultimate strength level.

Protecting Privacy of User Data in Intelligent Transportation Systems

  • Yazed Alsaawy;Ahmad Alkhodre;Adnan Abi Sen
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.5
    • /
    • pp.163-171
    • /
    • 2023
  • The intelligent transportation system has made a huge leap in the level of human services, which has had a positive impact on the quality of life of users. On the other hand, these services are becoming a new source of risk due to the use of data collected from vehicles, on which intelligent systems rely to create automatic contextual adaptation. Most of the popular privacy protection methods, such as Dummy and obfuscation, cannot be used with many services because of their impact on the accuracy of the service provided itself, they depend on changing the number of vehicles or their physical locations. This research presents a new approach based on the shuffling Nicknames of vehicles. It fully maintains the quality of the service and prevents tracking users permanently, penetrating their privacy, revealing their whereabouts, or discovering additional details about the nature of their behavior and movements. Our approach is based on creating a central Nicknames Pool in the cloud as well as distributed subpools in fog nodes to avoid intelligent delays and overloading of the central architecture. Finally, we will prove by simulation and discussion by examples the superiority of the proposed approach and its ability to adapt to new services and provide an effective level of protection. In the comparison, we will rely on the wellknown privacy criteria: Entropy, Ubiquity, and Performance.

Design criteria for birdstrike damage on windshield

  • Marulo, Francesco;Guida, Michele
    • Advances in aircraft and spacecraft science
    • /
    • v.1 no.2
    • /
    • pp.233-251
    • /
    • 2014
  • Each aircraft have to be certified for a specified level of impact energy, for assuring the capability of a safe flight and landing after the impact against a bird at cruise speed. The aim of this research work was to define a scientific and methodological approach to the study of the birdstrike phenomenon against several windshield geometries. A series of numerical simulations have been performed using the explicit finite element solver code LS-Dyna, in order to estimate the windshield-surround structure capability to absorb the bird impact energy, safely and efficiently, according to EASA Certification Specifications 25.631 (2011). The research considers the results obtained about a parametric numerical analysis of a simplified, but realistic, square flat windshield model, as reported in the last work (Grimaldi et al. 2013), where this model was subjected to the impact of a 1.8 kg bird model at 155 m/s to estimate the sensitivity of the target geometry, the impact angle, and the plate curvature on the impact response of the windshield structure. Then on the basis of these results in this paper the topic is focused about the development of a numerical simulation on a complete aircraft windshield-surround model with an innovative configuration. Both simulations have used a FE-SPH coupled approach for the fluid-structure interaction. The main achievement of this research has been the collection of analysis and results obtained on both simplified realistic and complete model analysis, addressed to approach with gained confidence the birdstrike problem. Guidelines for setting up a certification test, together with a design proposal for a test article are an important result of such simulations.

A Numerical Study of the High-Velocity Impact Response of a Composite Laminate Using LS-DYNA

  • Ahn, Jeoung-Hee;Nguyen, Khanh-Hung;Park, Yong-Bin;Kweon, Jin-Hwe;Choi, Jin-Ho
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.3
    • /
    • pp.221-226
    • /
    • 2010
  • The failure of a Kevlar29/Phenolic composite plate under high-velocity impact from an fragment simulation projectile was investigated using the nonlinear explicit finite element code, LS-DYNA. The composite laminate and the impactor were idealized by solid elements, and the interface between the laminas was modeled as a tiebreak type in LS-DYNA. The interaction between the impactor and laminate was simulated using a surface-to-surface eroding contact algorithm. When the stress level meets the given failure criteria, the layer in the element is eroded. Numerical results were verified through existing test results and showed good agreement.

A Combined Rating System for Multiple Noises in Residential Buildings (공동주택 복합 생활소음의 통합 평가등급)

  • Ryu, Jong-Kwan;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1005-1013
    • /
    • 2006
  • A survey and auditory experiment on multiple residential noises such as floor impact, airborne, bathroom, drainage and traffic noises were conducted to develop a combined rating system and to establish criteria for multiple residential noises. Subjective reactions such as annoyance, activity disturbance, sleep disturbance, and satisfaction to overall noise environment and each residential noise were recorded. The effect of individual noise perception on the evaluation of the overall noise environment was also investigated. The survey results showed that satisfaction for floor impact noise most greatly affects the overall satisfaction for overall noise environment and annoyance most greatly affects the satisfaction for individual noise sources. Auditory experiments were undertaken to determine the percent satisfaction for individual noise levels. Result of auditory experiment showed that the noise level corresponding to 40 % satisfaction is 49 dB $(L_{i,Fmax,AW})$ for floor impact and is about 40 dB(A) for airborne, drainage and traffic noise. From the results of the survey and the auditory experiments, an equation for predicting the overall satisfaction for multiple noises was developed and a classification of multiple residential noises was proposed.