• Title/Summary/Keyword: Impact hammer

Search Result 242, Processing Time 0.015 seconds

Vibration Mode Measurement Test of External Fuel Tank for Aircraft (항공기용 외부연료탱크 진동모드 측정시험)

  • Kim, Hyun-gi;Choi, Hyun Kyung;Kim, Sungchan;Park, Hyung Bae;An, Su Hong;Kim, Young Shin
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.4
    • /
    • pp.88-94
    • /
    • 2022
  • The vibration mode measurement test measures the natural vibration characteristics of the target specimen. The measured natural mode characteristics are compared with the numerical analysis result to verify the reliability of the numerical analysis. If necessary, it is used to supplement the numerical analysis model of the specimen used for the dynamic characteristic analysis. In this paper, the natural frequency and natural mode of the external fuel tank are respectively obtained through the vibration mode measurement test and the numerical analysis, using the finite element model. The results are compared to verify the reliability of the numerical analysis model of the external fuel tank to apply to the entire aircraft model. To measure the vibration mode of the test specimen, a bungee cord was used, to simulate the free boundary condition for the test specimen. And, 3-axis accelerometers were installed on the test specimen. The response characteristics of the test specimen were measured, by excitation with an impact hammer. As a result of the test, after performing the frequency response analysis on the response acceleration, the natural frequency of the test specimen and its vibration mode were confirmed. The reliability of the numerical analysis model was verified by comparing the frequency and vibration mode, obtained through the test and the numerical analysis.

Seismic Performance Evaluation of Unreinforced and ECC-jacketed Masonry Fences using Shaking Table Test (진동대실험을 사용한 비보강 및 ECC 자켓 보강 조적담장의 내진성능평가)

  • Yonghun Lee;Jinwoo Kim;Jae-Hwan Kim;Tae-Sung Eom;Sang-Hyun Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.182-192
    • /
    • 2023
  • In this study, the efficacy of Engineered Cementitious Composite(ECC) jacket for masonry fences subjected to lateral dynamic load was experimentally verified through a shaking table test, comparing it with the performance of an unreinforced masonry(URM) fence. Firstly, dominant frequencies, modal damping ratios and deformed shapes were identified through an impact hammer test. URM and ECC-strengthened fences with heights of 940mm and 970mm had natural frequencies of 6.4 and 35.3Hz, and first modal damping ratios of 7.0 and 5.3%, respectively. Secondly, a shaking table test was conducted in the out-of-plane direction, applying a historical earthquake, El Centro(1940) scaled from 25 to 300%. For the URM fence, flexural cracking occurred at the interface of brick and mortar joint(i.e., bed joint) at the ground motion scaled to 50%, and out-of-plane overturning failure followed during the subsequent test conducted at the ground motion scaled to 30%. On the other hand, the ECC-jacketed fence showed a robust performance without any crack or damage until the ground motion scaled to 300%. Finally, the base shear forces exerted upon the URM and ECC-jacketed fences by the ground motions scaled to 25~300% were evaluated and compared with the ones calculated according to the design code. In contrast to the collapse risk of the URM fence at the ground motion of 1,000-year return period, the ECC-jacketed fence was estimated to remain safe up to the 4,800-year return period ground motion.