• Title/Summary/Keyword: Impact Power Characteristics

검색결과 415건 처리시간 0.023초

고내압 특성을 위한 진성영역과 트렌치 구조를 갖는 베이스 저항 사이리스터 (A Novel Trench Electrode BRT with the Intrinsic Region for Superior Electrical Characteristics)

  • 강이구;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제15권3호
    • /
    • pp.201-207
    • /
    • 2002
  • In this paper, we haute proposed a novel trench electrode Base Resistance Thyristor(BRT) and trench electrode BRT with a intrinsic region. New power BRTs have shown superior electrical characteristics including the snab-back effect and the forward blocking voltage more than the conventional BRT. Especially, the trench electrode BRT with the intrinsic region has obtained high blocking voltage of 1600V. The blocking voltage of conventional BRT is about 400V at the same size. Because the breakdown mechanism of the BRT is the avalanch breakdown by impact ionization, the trench electrode BRT with intrinsic region has suppressed impact ionization, effectively. If we use this principle, we can develop a super high voltage power device and it applies to another power device including IGBT, EST and etc.

철도소음 영향평가를 위한 예측기술 동향 (A Tendency of Prediction Technique for the Assessment of Railway Noise)

  • 조준호;박영민;선효성;홍웅기
    • 환경영향평가
    • /
    • 제16권1호
    • /
    • pp.99-105
    • /
    • 2007
  • Since 1990s, the railway noise has been researched and developed in our nation. First of all, what's causing the noise and how to eliminate the cause of the noise must be found out. Secondly, cutting off the propagation path of the noise from the noise source to the receiving points. In this study the characteristics of prediction formula for the assessment of railway noise used in some nations including Korea were investigated. In order to develop the prediction formula of the railway noise, the noise radiated from railway vehicle, rails and sleepers, characteristics of noise barrier, velocity of train, ground effects, roughness should be analyzed and predicted. Especially, on the basis of acoustics, the characteristics of source are applied to acoustic power and directivity information.

50 nm Impact Ionization MOS 소자의 Subthreshold 특성 (Subthreshold Characteristics of a 50 nm Impact Ionization MOS Transistor)

  • 윤지영;유장우;정민철;성만영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.105-106
    • /
    • 2005
  • The impact ionization MOS (I-MOS) transistor with 50nm channel length is presented by using 2-D device simulator ISE-TCAD. The subthreshold slope cannot be steeper than kT/q since the subthreshold conduction is due to diffusion current. As MOSFETs are scaled down, this problem becomes significant and the subthreshold slope degrades which leads an increase in the off-current and off-state power dissipation. The I-MOS is based on a gated p-i-n structure and the subthreshold conduction is induced by impact ionization. The simulation results show that the subthreshold slope is 11.7 mV/dec and this indicates the I-MOS improves the switching speed and off-state characteristics.

  • PDF

TFT-LCD 모듈의 충격해석을 통한 내충격설계 연구 (Study on Shock Resistance Design of TFT-LCD Module using Explicit Impact Analysis)

  • 김진곤;이재곤
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.24-29
    • /
    • 2010
  • TFT-LCD module with thin, small and layered structure makes its shock analysis very difficult and complicated. As TFT-LCD becomes more thinner, it is more difficult to assure its required shock resistance. Recently, the drop/impact simulation using the commercial explicit dynamic analysis software such as LS-DYNA3D is actively applied to assess the shock characteristics of TFT-LCD. In this study, the effects of analysis parameters and design modifications in the drop/impact simulation are carefully studied. the reliability of the present analysis results can be assured through the experimental verification.

Flexible Transmission Expansion Planning for Integrating Wind Power Based on Wind Power Distribution Characteristics

  • Wang, Jianxue;Wang, Ruogu;Zeng, Pingliang;You, Shutang;Li, Yunhao;Zhang, Yao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.709-718
    • /
    • 2015
  • Traditional transmission planning usually caters for rated wind power output. Due to the low occurrence probability of nominal capacity of wind power and huge investment in transmission, these planning methods will leads to low utilization rates of transmission lines and poor economic efficiency. This paper provides a novel transmission expansion planning method for integrating large-scale wind power. The wind power distribution characteristics of large-scale wind power output and its impact on transmission planning are analyzed. Based on the wind power distribution characteristics, this paper proposes a flexible and economic transmission planning model which saves substantial transmission investment through spilling a small amount of peak output of wind power. A methodology based on Benders decomposition is used to solve the model. The applicability and effectiveness of the model and algorithm are verified through a numerical case.

유리 파단면의 화재감식에 관한 실험적 연구 (An Experimental Study on the Fire Investigation to the Broken Plane Types of Glass)

  • 문용수;공하성
    • 대한안전경영과학회지
    • /
    • 제10권4호
    • /
    • pp.105-109
    • /
    • 2008
  • The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates ($30cm{\times}30cm{\times}5mm$) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.

튜브와 지지대 사이의 동적상호 충격력 측정장치 특성규명에 관한 연구 (A Study on the Characteristics of the Tube-to-Support Dynamic Impact Force Measurement Facility)

  • 김일곤;박진무
    • 소음진동
    • /
    • 제5권1호
    • /
    • pp.95-106
    • /
    • 1995
  • Flow-induced vibration in heat exchanger (or fuel rod) in nuclar power plant can cause dynamic interactions between tubes and tube supports resulting in fretting-wear. To increase the reliability and design life of heat exchanger components, design criteria that establish acceptable limits of vibration and minimize fretting wear are necessary. The fretting-wear rate is dependent upon material combination, contact configuration, environmental conditions and tube-to tube support dynamic interaction. It is demostrated that the fretting -wear rate correlates well with tube-to-support contact force or work rate. The tube-to-support dynamic interaction, which consists of dynamic contact forces and tube motion, is used to relate single-span wear data to real heat exchanger configurations consisting of multi-span tube bundles. This paper describes the test facility to measure tube-to-support dynamic impact force and reports its dynamic characteristics through the four impact tests - a force transduces independent and external impact tests, central ring inside impact test and additional cylinder impact test. Through the tests the impact parameter change dependent upon the material difference of impacting ball is studied, and the impact parameters of Force Transducer Assembly components are measured. And also the dynamic behavior of Force Transducer Assembly is analyzed. The force measurement technique herein is shown to provide a reasonable measure of dynamic contact forces.

  • PDF

계통연계 풍력발전시스템의 무효전력 보상에 대한 시뮬레이션 (Simulation of Reactive Power Compensation in Grid-Connected Wind Power Generation System)

  • 노경수;장보경
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.82-89
    • /
    • 2011
  • Reactive power support is considered to be necessary for dealing with a voltage stability issue with wind turbine system employing squirrel-cage induction generator(SCIG). This paper analyses steady-state characteristics of the SCIG wind turbine system by simulating torque-slip characteristics of SCIG with respect to variations of interconnecting network strength and generator terminal voltage. It also presents dynamics analysis of SCIG wind turbine system on Simulink to investigate the impact of static var compensator(SVC) and static synchronous compensator(STATCOM) on transient stability enhancement. It analysed transient stability with varying fault duration times and compared the transient stability characteristics with varying rated capacities of SVC and STATCOM. It is shown that the STATCOM has a better performance and reactive power support compared to SVC.

An Investigation into the Impact on Voltage Sag due to Faults in Low Voltage Power Distribution Systems

  • Aggarwal R. K.
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.97-102
    • /
    • 2005
  • Voltage sags are the most widespread quality issues affecting distribution systems. This paper describes in some detail the voltage sag characteristics due to different types and locations of fault in a practical low voltage power distribution system encountered in the UK. The results not only give utility engineers very useful information when identifying parts of the system most likely to pose problems for customer equipments, but also assist the facility personnel to make decisions on purchasing power quality mitigation equipment.

충격에너지를 활용한 압전 발전기의 특성을 이해하기 위한 실험 연구 (A Experimental Study to Understand of a Characteristics of a Piezo-Generator using Impact Energy)

  • 이재준;문학룡;권수안;류승기
    • 대한토목학회논문집
    • /
    • 제31권5D호
    • /
    • pp.689-695
    • /
    • 2011
  • 본 논문에서는 도로공간에서 전력 생성이 가능한 신재생 에너지 기술들 중에서 압전효과를 활용하는 방법에 대한 연구를 수행하였다. 도로공간을 주행하는 수많은 차량을 이용하여 전력을 생성할 수 있는 신재생에너지 기술 연구의 일환으로, 외부의 충격하중을 전기에너지로 바꾸어 주는 압전효과를 이용하여 도로공간에 적용가능한 압전발전기를 개발하기 위한 기초연구를 수행하였다. 압전세라믹을 이용한 압전발전 수확기를 개발하기 위한 충격하중에 따른 특성 실험을 하였다. 압전발전기 형상 개발을 위해 충격하중 전달 방법, 충격흡수에 따른 압전세라믹의 발전 특성, 충격하중의 종류에 따른 압전 발전 수확기의 전압 발전 특성을 비교분석 하였다.