• 제목/요약/키워드: Impact Power Characteristics

검색결과 415건 처리시간 0.03초

PSS/E를 이용한 제주계통의 DFIG 풍력발전단지 및 HVDC 동적모델 개발 (Development of Dynamic Models for DFIG Wind Farms and HVDC in Jeju Power System Using PSS/E)

  • 남순열;강상희;남해곤;최준호
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2183-2189
    • /
    • 2011
  • Since main portion of the required electric power in Jeju Island is provided from the mainland through two HVDC lines, Jeju HVDC has a most significant impact on Jeju power system. Average wind speed of Jeju Island is the highest among several candidates in South Korea. So, Jeju Island has been a suitable site for the construction of wind farms where several wind farms are now operating and several others to be sited. Since the large-scale wind generation could have adverse impacts on the stable operation of Jeju power system, wind power is also important for the stability of Jeju power system. Therefore, accurate modeling of Jeju HVDC and wind farms is required for stability analysis of Jeju power system. In this paper, PSS/E-based dynamic modeling of Jeju HVDC and DFIG wind farms is proposed. Model-writing technique of PSS/E is used to develop USRAUX model and USRMDL model for controlling the frequency of HVDC and imposing an operation limit of wind power, respectively. Dynamic characteristics of Jeju HVDC and DFIG wind farms are analyzed through the dynamic simulations. The simulation results show the effectiveness of the developed models for Jeju power system.

부하수준 별 한계손실계수 변동특성 분석 (Analysis of MLF Characteristics on 12 Load Levels)

  • 문영환;김호용;남궁재용;심우정
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.284-289
    • /
    • 2002
  • The transmission networks do not consist of perfect conductors and a percentage of the power generated is therefore lost before it reaches the loads. Since this network loss contributes to the cost of suppling power to consumers, it must be considered that the most efficient dispatch and location of generators and loads are to be achieved. In this paper, marginal loss factors are calculated for 12 load levels that represent the impact of marginal network losses on nodal prices at the transmission network connection points at which generators are located. Based on comparison analysis of marginal loss factors on 12 load levels, we found the MLF characteristics in KOREA.

부하시점에 따른 지역별 한계손실계수 변동특성 분석 (Analysis of Regional MLF Characteristics on 12 Load Cases)

  • 남궁재용;문영환;오태규;임성황
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.333-335
    • /
    • 2001
  • The transmission networks are not perfect conductors and a percentage of the power generated is therefore lost before it reaches the loads. This network loss contributes to the cost of suppling power to consumers, and must be considered if the most efficient dispatch and location of generators and loads are to be achieved. In this paper, marginal loss factors are calculated for 12 load cases that represent the impact of marginal network losses on nodal prices at the transmission network connection points. Based on comparison analysis of marginal loss factors for 12 loaf cases, we can find the regional MLF characteristics in KOREA.

  • PDF

석탄가스화 화학반응의 기본 특성 분석 연구 (Characteristics of Chemical Reactions in Coal Gasification Processes)

  • 백승철;손정락;송성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3125-3130
    • /
    • 2008
  • Coal is one of the most abundant and cheapest energy sources in the earth, but its typical combustion product, $CO_2$, is related with serious recent environmental issues such as global warming. The Integrated Coal Gasification Combined Cycle (IGCC) with $CO_2$ sequestration is one of the most promising options to produce electricity using a relatively cheap fuel (coal) with minimum impact on environment. In IGCC power generation systems, some chemical reactions are required to gasify coal to produce syngases such as $H_2$ and CO, which would be burnt in the combustor to produce heat for power generation, with a penalty of additional energy consumption. In this paper, several chemical reactions for the gasification of coal are considered and their characteristics are investigated.

  • PDF

Frequency Tuning Characteristics of a THz-wave Parametric Oscillator

  • Li, Zhongyang;Bing, Pibin;Xu, Degang;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.97-102
    • /
    • 2013
  • Frequency tuning characteristics of a THz-wave by varying phase-matching angle and pump wavelength in a noncollinear phase-matching THz-wave parametric oscillator (TPO) are analyzed. A novel scheme to realize the tuning of a THz-wave by moving the cavity mirror forwards and backwards is proposed in a noncollinear phase-matching TPO. The parametric gain coefficients of the THz-wave in a $LiNbO_3$ crystal are explored under different working temperatures. The relationship between the poling period of periodically poled $LiNbO_3$ (PPLN) and the THz-wave frequency under the condition of a quasi-phase-matching configuration is deduced. Such analyses have an impact on the experiments of the TPO.

Seismic performance assessment of NPP concrete containments considering recent ground motions in South Korea

  • Kim, Chanyoung;Cha, Eun Jeong;Shin, Myoungsu
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.386-400
    • /
    • 2022
  • Seismic fragility analysis, a part of seismic probabilistic risk assessment (SPRA), is commonly used to establish the relationship between a representative property of earthquakes and the failure probability of a structure, component, or system. Current guidelines on the SPRA of nuclear power plants (NPPs) used worldwide mainly reflect the earthquake characteristics of the western United States. However, different earthquake characteristics may have a significant impact on the seismic fragility of a structure. Given the concern, this study aimed to investigate the effects of earthquake characteristics on the seismic fragility of concrete containments housing the OPR-1000 reactor. Earthquake time histories were created from 30 ground motions (including those of the 2016 Gyeongju earthquake) by spectral matching to the site-specific response spectrum of Hanbit nuclear power plants in South Korea. Fragility curves of the containment structure were determined under the linear response history analysis using a lumped-mass stick model and 30 ground motions, and were compared in terms of earthquake characteristics. The results showed that the median capacity and high confidence of low probability of failure (HCLPF) tended to highly depend on the sustained maximum acceleration (SMA), and increase when using the time histories which have lower SMA compared with the others.

Compensation for Photovoltaic Generation Fluctuation by Use of Pump System with Consideration for Water Demand

  • Imanaka, Masaki;Sasamoto, Hideki;Baba, Jumpei;Higa, Naoto;Shimabuku, Masanori;Kamizato, Ryota
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1304-1310
    • /
    • 2015
  • In remote islands, due to expense of existing generation systems, installation of photovoltaic cells (PVs) and wind turbines has a chance of reducing generation costs. However, in island power systems, even short-term power fluctuations change the frequency of grids because of their small inertia constant. In order to compensate power fluctuations, the authors proposed the power consumption control of pumps which send water to tanks. The power control doesn’t affect water users’ convenience as long as tanks hold water. Based on experimental characteristics of a pump system, this paper shows methods to determine reference power consumption of the system with compensation for short-term PV fluctuations while satisfying water demand. One method uses a PI controller and the other method calculates reference power consumption from water flow reference. Simulations with a PV and a pump system are carried out to find optimum parameters and to compare the methods. Results show that both PI control method and water flow calculation method are useful for satisfying the water demand constraint. The water demand constraint has a little impact to suppression of the short-term power fluctuation in this condition.

간호사 노동시장의 수요독점에 대한 연구 - 종합병원을 중심으로 - (Monopsony Power of General Hospitals in Nurse Labor Market)

  • 정현진;양봉민
    • 한국병원경영학회지
    • /
    • 제5권2호
    • /
    • pp.40-58
    • /
    • 2000
  • Nurses are medical personnel, who play a key role in supporting patient care, so it is important to supply them adequately in balance with ever increasing medical demand. But there appears severe shortage of nurses in some hospitals because of their uneven distribution, especially in small sized-hospitals and rural-hospitals. As nationwide distorted distribution of nurses in Korea is just like what monopsony model(a kind of market structure model) tells us, it is attempted to explain this situation of nurse labor market in Korea on the basis of monopsony model and presented in this paper. Specifically, determinants of nurse wage and the level of their relative employment were examined, and monopsony impact on their wage and the level of relative employment controlling those determinants were studied. Major results of this study arc as follows. The most important determinant of nurse wage level in this study was the wage level of a local community where each hospital located Hospital owner's characteristics an educational function of each hospital were also important factors. With these factor controlled, it was found that monopsony power of each hospital was negativel associated with nurse wage level as expected. 1% increase in monopsony power of hospital(measured by Herfindah-Hirschman Index) reduced nurse wage by $5,674{\sim}19,19$ won(in Korean currency). With regard to the level of relative employment, the most important determinant wa the capacity for supplying nurses of the local community. Again, hospital owner characteristics and educational function of each hospital were also important. With these factors controlled, it was found that monopsony power of each hospital was negative associated with the number of nurses per bed, as expected. 1% increase in monopsony power of each hospital(again measured by Herfindah-Hirschman Index) reduced the number of nurses per 100 bed as much as $0.46{\sim}0.67$. In conclusion. structural factors of nurse labor market influence the instability of nurse labor supply in Korea. Further consideration for these market structural characteristics needed for policy making related to nurse resource allocation.

  • PDF

Landsat 열적외 영상자료를 활용한 대전시 열 환경 변화 모니터링 (Monitoring of Urban Thermal Environment Change in Daejun Using Landsat TIR Satellite Data)

  • 최진호;조현주;정환도
    • 환경영향평가
    • /
    • 제22권5호
    • /
    • pp.513-523
    • /
    • 2013
  • This purpose of this work is to explore the characteristics of urban thermal environment distribution with the case of Daejeon. To do that, this work applied GIS Spatial Statistics to the LandSAT images gathered from 2000 to 2011. The urban thermal environment distribution at the time point of 2 showed high spatial autocorrelation. Therefore, it is judged that spatial autocorrelation is needed to increase the reliability and explanatory power of the characteristics of thermal environment distribution. In the case of the thermal in Daejeon, its positive clustering appeared high at the time point of 2, and its clustering in 2011 more gradually decreased than that in 2000 to 2011. In particular, given the decrease in the core H-H region, it was found that the thermal environment of Daejeon was greatly improved. However, since the rise in the region L-L means another changed like construction of a new city, it is judged that it is necessary to come up with a proper plan. It is considered that this analysis of the characteristics of urban thermal environment distribution in consideration of spatial autocorrelation L-L be useful for providing a fundamental material necessary for the policy and project of thermal environment improvement.

부순모래 사용에 따른 원전 구조물용 콘크리트의 기초적 특성 (Fundamental Characteristics of Concrete for Nuclear Power Plant Using Crushed Sand)

  • 박성학;김경환;최병걸;최연왕
    • 한국건설순환자원학회논문집
    • /
    • 제5권2호
    • /
    • pp.168-176
    • /
    • 2017
  • 본 연구에서는 원전 구조물용 콘크리트의 잔골재로 부순모래를 사용하기 위한 연구의 일환으로 기존의 부순모래 생산공정에서 임팩트크러셔(Impact crusher)의 성능(회전수)을 높여 입형을 개선하고 ASTM C 33에 적합하도록 입도를 조정한 부순모래의 입형 및 입도 특성을 검토하였으며, 강모래에 대한 치환률에 따라 콘크리트를 제조하여 콘크리트 배합 특성, 굳지 않은 콘크리트 특성 및 경화한 콘크리트 특성을 검토하였다. 실험결과, 대부분의 콘크리트 특성이 강모래만을 사용한 콘크리트와 동등한 수준으로 나타났지만, 강모래에 대한 치환률 50% 이상일 경우, 치환률 증가에 따라 허용 범위 내에서 공기량, 압축강도 및 인장강도는 다소 감소되는 것으로 나타났다.