• Title/Summary/Keyword: Impact Noise

Search Result 1,307, Processing Time 0.184 seconds

Noise Test of High-speed Train at 300km/h (경부고속철도 300km/h 주행시 소음 평가)

  • 나희승;김준엽
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.452-457
    • /
    • 2002
  • High speed railroad noise is one of the main causes of environmental impact. An estimate of the relevant noise levels is usually required in order to evaluate the noise barrier and the anti-noise trailer. This paper introduce the test procedure and the estimate for HST noise. The aim of this is to measure, by means of a test, the level of acoustic pressure present during the passing of a KTX(Korea Train Express), in order to satisfy the contractual requirements and the noise criteria. A number of measurements are carried out in order to estimate noise impact by HST along test track.

  • PDF

Noise Contour Map Designed from Validation Study of Model for Predicting Aircraft Noise (항공기 소음모델의 정합성 평가를 통한 소음지도 작성)

  • Yim, Bongbeen;Kim, Jooin;Lee, Kyusung;Hong, Hyunsu;Kim, Suntae
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.893-901
    • /
    • 2012
  • Aircraft noise model such as FAA Integrated Noise Model(INM) has recently been used for forecasting the impact of noise in a residential area near an airport and quantifying the effect of various options for noise mitigation. The noise modeling should be reliable and precise in order to ensure the quality of the results provided. In this study, the validation of the noise levels simulated by the INM against measurement data recorded continuously at multiple monitoring sites was discussed. As a result of validation, the quality of the input data used as a fixed point profiles for the INM was enhanced. The noise contour maps were designed as a way to evaluate the aircraft noise of the vicinity of the airfield. The results of this study indicate that the validation of aircraft noise model by the measurement data would be required for the accurate assessment of the aircraft noise levels.

Noise Source Identification and Countermeasure for the Noise of LPG Injector (LPC 인젝터의 소음원 규명 및 소음저감 대책)

  • Kim, Won-Jin;Park, Chong-Hyun;Kim, Sung-Dae;Lee, Byung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.3
    • /
    • pp.144-151
    • /
    • 2002
  • This work focuses on finding out the noise source and the method of reducing the noise level of LPG(liquefied petroleum gas) fuel injector. The noise of LPG injector in operating condition is due to the impact between valve and valve seat. This study shows that if the revolution of engine is increased, the noise of LPG injector will be more serious but it is not nearly affected by the increment of fuel pressure. The source and transmission paths of noise are identified through the analysis of noise generation mechanism and noise spectrum. The sound absorbing material is tested to verify its efficiency of sound absorption thor the LPG injector. The effect of noise reduction of absorbing material is remarkable when the engine speed is high. Consequently two methods of reducing the noise level are suggested from the identified results. The one is to equip the absorbing material on the outer side of injector and the other is to coat with a soft material or equip a soft ring on the surface of impact.

A Study on the Noise Measurement Method of Wind Power Facilities (풍력발전시설 소음 측정 방법에 대한 고찰)

  • YoungJin Lee;Jongtae Lee;Hyunkyung Min;Sunyong Kwon;Byungchan Lee
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.279-290
    • /
    • 2023
  • Recently, as wind farms using wind power as new and renewable energy have been installed nationwide, noise problems have emerged. The environmental impact assessment and post-environmental impact assessment also require the measurement of background noise and low-frequency noise for wind farms, especially by applying the living noise measurement method according to the low-frequency noise management guidelines issued by the Ministry of Environment in 2018. Due to the nature of wind power generators that generate loud noise in high winds, noise measurement should be made at high winds, but when wind speed increases, wind noise increases and living noise and low-frequency noise are not properly evaluated. Therefore, the type of noise generated by wind power generators was confirmed, and matters to be considered when measuring wind noise such as wind noise were confirmed.

A Study on the Development of High Performance Floor Impact Noise Insulation System (고성능 바닥충격음 차단구조 개발에 관한 연구)

  • Jang, Jae-Hee
    • KIEAE Journal
    • /
    • v.7 no.2
    • /
    • pp.71-76
    • /
    • 2007
  • For the many years the children's running noise has caused perpetual frictions between neighbors in apartment houses. For this reason the government established a regulation to reduce the floor impact noise, as a result almost all apartment houses have been enforced to use the floor structure with 210mm thickness concrete slab and 120mm thickness of floor heating system since July 2005. If do not want to apply this kind of system, a system which obtain the certification from the institution appointed by government must be applied. In this reason a lot of construction material companies and construction companies have been trying to develop the system with 180mm thickness concrete slab for the purpose of reducing the cost. To develop the optimized floor system, actual size test building were constructed and the materials related with reducing floor impact noise were composited and tested in the test building. Through this procedure the most effective system was found.

Case_study of detecting loose part by acceleration signal (가속도 충격파형을 이용한 기기의 결함 위치분석 및 진단사례)

  • Yoo, Mu-Sang;Park, Seung-Do;Park, Hyeon-Cheol;Choi, Nak-Kyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.463-468
    • /
    • 2007
  • The abnormal sound of generator frame is analyzed by a acceleration signal. The spike-like time signal is major characteristics of impacting force. The distributional map of vibration level is one of visualization method. With map, noise source was easily detected. After de_assembly of generator, loose part of internal component is the source of impact force by mechanical movement of stator inherently. In contact condition of part with clearance, the level of impact signal is different at each revolution and impact signal did not happens periodically.

  • PDF

A Development of COS Fuse Holder to Reduce an Impact Ambient Noise (충격성소음저감용 COS 휴즈 홀더 개발)

  • Cho, Hyun-Seob;Min, Jin-Kyoung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.11a
    • /
    • pp.176-179
    • /
    • 2006
  • We are using COS to purpose blocking the excess current and to protect the transformer. But the fuse of COS is melt due to the overload if the excess current flows and it destroy an air severing relations to clear as strong arc happens. Such phenomenon induces an impact ambient noise and it gives the circumstance area resident or pedestrian the fear. Thus, We are the actual circumstances which an ambient noise countermeasure establishment have desired urgently. In this study, we grasp the characteristic of an impact ambient noise which a COS fuse happens the melting and study the method to reduce an impact ambient noise.

  • PDF

Estimation of Subjective Evaluations for Impact Sound and Analysis of the Effects for Parts of a Car (자동차 임팩트 소음에 대한 주관적 평가 및 차량 개발에 응용)

  • Park, Sang-Won;Lee, Sang-Kwon;Bae, Byung-Kuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.37-44
    • /
    • 2010
  • Impact noise is induced in a car when it is driven on a harsh road or over some bumps. This noise occurs with the very high level of sound, which affects passengers in some way or other. Although it is impossible to clearly remove such noise, it is necessary to research an improvement in sound quality for impact noise. A new sound metric for impact sound is presented. This metric is verified by comparison between mean subjective ratings and several sound metrics. In this paper, more objective attributes are considered, which the attributes are expressing the level and modulation of sound. Three sound metrics are employed to get impact sound indexes for each course by the method of multiple linear regressions. The indexes are verified by considering the correlation between the estimated values from the multiple linear regressions and the mean subjective ratings by evaluators. Also, the subjective ratings on the indexes are estimated for the case in which some parts of suspension system are changed. The estimated ratings represent more reasonable or acceptable ratings. Thus, such indexes can be used for modification of the parts of suspension system under considering a good sound quality.

An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis (시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung;Hong, Geon-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.5
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.

Analysis of Impact Responses Considering Sensor Dynamics (센서 동역학을 고려한 충격응답해석)

  • B. J. Ryu;K. Y. Ahn;B. H. Kwon;I. S. Oh;Lee, G. S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.373.1-373
    • /
    • 2002
  • Impact is the most common type of dynamic loading conditions that give rise to impulsive forces and affects the vibrational characteristics of mechanical systems. Since the impact force and response are measured indirectly through the sensors, it is difficult to predict the impact force and acceleration. In this study, contact force model based on the Hertz law is proposed in order to predict the impact force correctly. (omitted)

  • PDF