• Title/Summary/Keyword: Impact Force Measurement

Search Result 81, Processing Time 0.026 seconds

Soil Plugging Behavior of Open -ended Pile for Different Installation Methods (말뚝의 설치 방법에 따른 관내토의 폐색 거동)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.11 no.4
    • /
    • pp.25-36
    • /
    • 1995
  • A specially designed model open -ended pile, which was composed of inner tube and outer tube, wry driven in the pressure chamber by two diffenent intallation methods, that is, impact -driving and vibratory driving, and static compression loading test was done for that pile. Through the measurement of bearing capacities in the separated resisting parts of open -ended pile, bearing mechanism of open-ended pile and soil plugging behaviors for different installation methods were studied. It appears that 20% out of soil plugging force of impact -driven pile was developed during driving, while the rest was developed during static compression loading and t.he magnitude of confining pressure applied to the chamber did not affect soil plugging behavior. Also. it appears that, soil plugging force of vibratory pile was not developed during driving, while it was developed weakly as about 0.5~0.7 times as that of impact pile during static compression loading. and the confining pressure of pressure rhamber had an effect on the soil plugging. In the ultimate loading condition unit soil plugging force did not approach to the failure condition.

  • PDF

Equivalent static wind loads analysis of tall television towers considering terrain factors of hilltops based on force measurement experiment

  • Ke, Shitang;Wang, Hao;Ge, Yaojun;Zhao, Lin;Cao, Shuyang
    • Structural Engineering and Mechanics
    • /
    • v.63 no.4
    • /
    • pp.509-519
    • /
    • 2017
  • Wind field in mountainous regions demonstrates unique distribution characteristic as compared with the wind field of the flat area, wind load and wind effect are the key considerations in structural design of television towers situated in mountainous regions. The television tower to be constructed is located at the top of Xiushan Mountain in Nanjing, China. In order to investigate the impact of terrain factors of hilltops on wind loads, firstly a wind tunnel test was performed for the mountainous area within 800m from the television tower. Then the tower basal forces such as bending moments and shear strength were obtained based on high frequency force balance (HFFB) test. Based on the experiments, the improved method for determining the load combinations was applied to extract the response distribution patterns of foundation internal force and peak acceleration of the tower top, then the equivalent static wind loads were computed under different wind angles, load conditions and equivalent goals. The impact of terrain factors, damping ratio and equivalent goals on the wind load distribution of a television tower was discussed. Finally the equivalent static wind loads of the television tower under the 5 most adverse wind angles and 5 most adverse load conditions were computed. The experimental method, computations and research findings provide important references for the anti-wind design of high-rise structure built on hilltops.

Improvement of the Vibration Characteristics for the Oil Pipe Support Structure of the Crude Oil Carrier (설계개선에 의한 원유운반선 송유관 지지구조물의 진동 저감)

  • Kim Heui-Won;Park Jin-Hwa
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.69-75
    • /
    • 2005
  • Recently it was reported that the vibration problems on the oil pipe support structure of the crude oil carrier were occurred. in order to investigate the vibration characteristics and the causes of the vibration occasionally. the vibration measurements and impact tests for the oil Pipe structure were carried out. From the measurement results severe vibration was caused by the resonance between the transversal natural frequency of the structure and $6^{th}$ order excitation force of the main engine. Providing the proper countermeasures a series of the vibration analyses were carried out based on the measurement results. From the analysis results, it was concluded that the vibration characteristics of the oil pipe structure were affected by the oil pipes, support structure itself, upper deck structure and the installation spaces and the standard design was established for the crude oil carriers.

  • PDF

Analysis for the dynamic responses of pantograph-overhead contact line coupled system by using a condition monitoring system (상태감시시스템을 이용한 팬터그래프-전차선로 동특성 분석에 관한 연구)

  • Cho, Yong-Hyeon;Park, Young;Lee, Ki-Won;Kwon, Sam-Young;Park, Hyun-June
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.778-781
    • /
    • 2008
  • The aim of this paper is to analyze the dynamic responses of pantograph-overhead contact line coupled system by using a condition monitoring system. The monitoring items are strain, vertical displacement and acceleration of a contact wire. Both strain and vertical displacement in the contact wire depends on uplift force and train velocity. Measurement of acceleration shows that the passage of the pantograph gives an impact force to a hard point on a contact wire.

  • PDF

Railway structure health monitoring using innovative sensing technologies (첨단계측센서를 이용한 철도 구조물의 모니터링)

  • Lee, Kyu-Wan;Jung, Sung-Hoon;Park, Eun-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.772-777
    • /
    • 2008
  • Recent development of fiber optic sensors and wireless sensor technology, made structural health monitoring of railway structures cost effective. In this paper, a micro bending fiber optic rail pad sensors are evaluated for train axle force measurement. In order to assess the usability of FBG fiber optic sensors for short-term bridge measurement, the FBG sensors and conventional strain gauges are installed at the same points and the strain results are compared. Also the impact factors are calculated using the FBG strain responses and the results are compared with the conventional sensor responses. A running KTX train was instrumented with wireless sensor system to measure the vibration characteristics and the results are compared with conventional wire sensor system.

  • PDF

A Study on the Surface Properties Test of the Grinding Disk Assembly for Crushing Materials in Secondary Cells (이차전지 원료 해쇄용 그라인딩 디스크 어셈블리 표면 특성 시험에 관한 연구)

  • Sang-Pil Han;Dong-Hyuk Lee
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.33-41
    • /
    • 2023
  • Metal raw materials and chemical additives, which are raw materials for secondary batteries, are pulverized by the high-speed rotation of the Grinding Disc of the Classifier Separator Mill (CSM). Grinding discs are required to withstand abrasion, corrosion, high-speed rotational force and impact. In order to analyze the stability of domestic and foreign grinding discs, quality tests including surface roughness, surface lubrication, surface state measurement, and surface 3D shape measurement were analyzed. When producing developed products, it shows that excellent products can be produced.

Analysis of the Impact on Prediction Models Based on Data Scaling and Data Splitting Methods - For Retaining Walls with Ground Anchors Installed (데이터 스케일링과 분할 방식에 따른 예측모델의 영향 분석 - 그라운드 앵커가 설치된 흙막이 벽체 대상)

  • Jun Woo Shin;Heui Soo Han
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.639-655
    • /
    • 2023
  • Recently, there has been a growing demand for underground space, leading to the utilization of earth retaining walls for deep excavations. Earth retaining walls are structures that are susceptible to displacement, and their measurement and management are carried out in accordance with the standards established by the Ministry of Land, Infrastructure, and Transport. However, managing displacement through measurement can be considered similar to post-processing. Therefore, in this study, we not only predicted the horizontal displacement of a retaining wall with ground anchors installed using machine learning, but also analyzed the impact of the prediction model based on data scaling and data splitting methods while learning measurement data using machine learning. Custom splitting was the most suitable method for learning and outputting measurement data. Data scaling demonstrated excellent performance, with an error within 1 and an R-squared value of 0.77 when the anchor tensile force and water pressure were standardized. Additionally, it predicted a negative displacement compared to a model that without scaling.

Analysis of Effect of Pantograph Cover on the Current Collection Quality of High Speed Train using Real Train Experiment (실차시험을 통한 팬터그래프 커버가 고속열차의 집전성능에 미치는 영향에 대한 분석)

  • Oh, Hyuck Keun;Kim, Seogwon;Cho, Yong-hyun;Kwak, Minho;Kwon, Sam Young
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.409-416
    • /
    • 2016
  • The contact force characteristic between the pantograph and the catenary wire represents the current collection quality of trains; it should be precisely controlled under international standard. Recently, a noise reduction cover has been installed around the pantograph of high speed trains. However, little study on the contact force by the pantograph cover has been conducted. In this study, the impact on the current collection performance of the pantograph cover was analyzed by dynamic contact force measurement using a next generation high speed train (HEMU-430X). As a result, it was confirmed that the attachment of a pantograph cover could lower the mean contact force by approximately 50N at 300km/h. In addition, the pure difference of the average contact force by the presence of pantograph cover, except for the static pressure, was measured and found to be up to 110N at 300km/h. It was also found that the standard deviation of the contact force of 3~5N could be changed by use of a pantograph cover.

Identification of structural systems and excitations using vision-based displacement measurements and substructure approach

  • Lei, Ying;Qi, Chengkai
    • Smart Structures and Systems
    • /
    • v.30 no.3
    • /
    • pp.273-286
    • /
    • 2022
  • In recent years, vision-based monitoring has received great attention. However, structural identification using vision-based displacement measurements is far less established. Especially, simultaneous identification of structural systems and unknown excitation using vision-based displacement measurements is still a challenging task since the unknown excitations do not appear directly in the observation equations. Moreover, measurement accuracy deteriorates over a wider field of view by vision-based monitoring, so, only a portion of the structure is measured instead of targeting a whole structure when using monocular vision. In this paper, the identification of structural system and excitations using vision-based displacement measurements is investigated. It is based on substructure identification approach to treat of problem of limited field of view of vision-based monitoring. For the identification of a target substructure, substructure interaction forces are treated as unknown inputs. A smoothing extended Kalman filter with unknown inputs without direct feedthrough is proposed for the simultaneous identification of substructure and unknown inputs using vision-based displacement measurements. The smoothing makes the identification robust to measurement noises. The proposed algorithm is first validated by the identification of a three-span continuous beam bridge under an impact load. Then, it is investigated by the more difficult identification of a frame and unknown wind excitation. Both examples validate the good performances of the proposed method.

A Study on Improving Shock Absorption Test of Safety Helmet (안전모의 충격 흡수성 시험 개선에 관한 연구)

  • Sang Woo Shim;Yong Su Sim;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.36-42
    • /
    • 2023
  • In this study, 50 ABE-type hard hats were procured from five certified commercial manufacturers, and shock absorption tests were conducted in accordance with Protective Equipment Safety Certification Notice No. 2020-35. The tests were performed under both high- and low-temperature conditions, adhering to safety helmet testing standards. The highest shock transmission ranges were recorded in the tests, with an average energy range of 2,600-4,108 N at high temperatures and 2,316-3,991 N at low temperatures. All five hard hat models demonstrated a maximum transmitted impact force below 4,450 N, without any loss of cap and attachment functionality, confirming their compliance with performance standards. Furthermore, we evaluated the side impact performance of the safety helmets of each company, with an average range of 4,722-5,267 N. Company A exhibited the lowest measurement at 4,722 N. Comparing these results with international safety standards and the national shock absorption test criteria, it was observed that the maximum transmitted shock value using government-specified impact weight falls within the range of 4,450-5,000 N. However, it was noted that developed countries have established specific standards for the side impact forces on safety helmets, which are legally mandated. Consequently, it is imperative for South Korea to enhance its safety helmet side impact performance test methodology to align with domestic standards in the future.