• Title/Summary/Keyword: Immunoturbidimetric method

Search Result 4, Processing Time 0.019 seconds

Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer (자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가)

  • Jo, Yongjun;Lee, So-young;Park, Hae-il;Kim, YeongSic;Lee, Jehoon;Kim, Yonggoo;Han, Kyungja
    • Laboratory Medicine Online
    • /
    • v.2 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Background: Measurement of HbA1c levels is widely used to diagnose diabetes mellitus and to evaluate and monitor plasma-glucose concentrations over 6-8 weeks. In this study, we evaluated the diagnostic performance of the newly developed latex immunoturbidimetric method by using Autolab HbA1c. Methods: We analyzed and compared the diagnostic performance of Autolab HbA1c with that of Toshiba 200FR between April 2009 and July 2009. According to guidelines (EP5-A2, EP6-P, EP9-A2) of the clinical and laboratory standards institute (CLSI), we compared linearity, precision and correlation of Autolab HbA1c with those of G7 (Tosoh Corp., Kyoto, Japan) by using high-performance liquid chromatography (HPLC) method. Results: Data obtained using Autolab HbA1c showed good linearity in mixtures of samples with low (3.1%) and high (15.1%) levels of HbA1c (r2=0.9997). In the analysis of within-run precision of the samples with HbA1c levels of 5.1% and 12.1%, the SDs were 0.04 and 0.06 and covariances of these samples were 0.8% and 0.5%, respectively. In the Deming regression model, the regression equation was as follows: Autolab HbA1c=1.0859×Tosoh HPLC-0.6957. Conclusions: In this study, Autolab HbA1c method showed better performance characteristics than Tosoh G7 did. In reference review, there was no interference of variant hemoglobin. The data acquisition time of Autolab HbA1c was lower than that of Tosoh G7. The advantages of Autolab HbA1c are that it can be used as an autoanlyzer in routine chemical analysis, it does not require pre-analytical treatment, and the samples are automatically treated with distilled water for hemolysis.

Haptoglobin Concentration in the Cord Blood of Uninfected Korean Newborns

  • Choi, Seong Jin;Lee, Byoungkook;Ahn, Kwangjin;Uh, Young
    • Perinatology
    • /
    • v.29 no.4
    • /
    • pp.165-169
    • /
    • 2018
  • Objective: Highly sensitive haptoglobin measurement should be used in neonates because the haptoglobin concentration in neonates is lower than that of adults. The aim of this study was to establish the reference values of haptoglobin levels in the cord blood of uninfected neonates. Methods: The cord blood of 29 preterm and 51 term babies was collected, and data from the mother and the newborn were recorded. The haptoglobin concentrations of 80 cord blood samples were simultaneously measured by enzyme-linked immunosorbent assay (ELISA; Assaypro, St Charles, MO, USA) and immunoturbidimetry assay (Roche Diagnostics, Basel, Switzerland). C-reactive protein (CRP) was also measured by immunoturbidimetry assay (Roche Diagnostics, Switzerland). Results: Mean values of CRP and ELISA haptoglobin were not significantly different between preterm and term babies. The 2.5 percentile and 97.5 percentile values of ELISA haptoglobin concentration were as follows: 80 neonates, 0.01 mg/dL and 0.59 mg/dL; 29 preterm babies, 0.08 mg/dL and 0.18 mg/dL; and 51 term babies, 0.07 mg/dL and 0.23 mg/dL. There were no differences in ELISA haptoglobin concentration according to maternal underlying diseases, delivery method, usage of antibiotics or steroids before delivery, gestational age, gender of baby, or twin gestation. Conclusion: A highly sensitive haptoglobin method should be used to determine the haptoglobin concentration in Korean newborns because the reference values of cord blood haptoglobin concentration in Korean newborns are less than the lower detection limit for commonly used immunoturbidimetric haptoglobin measurement methods.

Obtaining Reference Intervals of HbA1c by Immunoturbidimetry (면역비탁법에 의한 HbA1c의 참고범위 설정)

  • Kim, Jae-Sub;Park, Ki-Hyun;Yu, Sun-Woo;Lee, Bum-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.2
    • /
    • pp.62-66
    • /
    • 2009
  • HbA1c is the major fraction of glycated hemoglobin, and used primarily to identify the average plasma glucose concentration over prolonged periods of time, mostly 2-3 months. It is used as markers for the diagnosis and monitoring of diabetic patients and increasingly used a marker in health screening check up for general populations. In this study, HbA1c was measured with Cobas integra 800 (Roche Diagnostics, Mannheim, Germany), using immunoturbidimetry principles. We established the reference interval for HbA1c with Cobas integra 800 and evaluated its significance. The study subjects were 36,140 (male 57.5%, and female 42.2%) who visited the Health Promotion Center of a tertiary care center in Seoul for health checkup from January to September, 2008. HbA1c levels were measured with immunoturbidimetric method. Statistical evaluation was done with SPSS. Comparison between male and female was checked with Mann-Whitney test, and among age groups with Kruskal-Wallis test. Reference interval for HbA1c was from 4.8% to 6.1%. There was no significant difference between male and female with Mann-Whitney test (P=0.539). There was significant difference among age groups with Kruskal-Wallis test (P<0.05). Reference interval for HbA1c with Cobas integra 800 was 4.8~6.1%, which was different from conventional one, 4.4-6.4%. Establishment of reference interval for each principle is needed.

  • PDF

Effects of Natural Honeybee (Apis mellifera ligustica) Venom Treatment on the Humoral Immune Response in Pigs (Beevenom 처리가 돼지의 체내 면역반응에 미치는 효과)

  • 조성구;김경수;이석천
    • Journal of Animal Science and Technology
    • /
    • v.48 no.6
    • /
    • pp.933-942
    • /
    • 2006
  • This experiment was carried out to investigate effects of honeybee venom treatment on the humoral immune response in pigs. Corresponding author : S. K. Cho, Dept. of Animal Sci. Chung-Buk National University, Kaesin-dong, Cheongju, 361-763, Korea. phone : 043-261-2551. E-mail : deercho@chungbuk.ac.kr To investigate effects of natural honeybee venom on the concentration of immunoglobulin G, A, and M, 20 piglets(LY×D) from 3 sows were allocated into two groups bee venom-treated group(10 piglets) and non-treated control(10 piglets). Natural honeybee venom was treated at 0, 3, 6 days after birth and the acupoints were Hai-men(ST-25), Du-kou(CV-8) and Jiao-chao(GV-1) points at 0, 3 days after birth and the regions of castration and tail amputation point at 6 days. Control group was injected 1㎖ of saline to the same site. Concentrations of IgG, A, and M were measured with immunoturbidimetric method at 0, 3, 7, 14, and 21 days after treatment. To investigate the effect of bee venom on the production of antibodies against hog cholera and atrophic rhinitis vaccines that were used as indicator antigens, 40 piglets(LYxD) from 5 sows were grouped as bee venom-treated group (20 piglets) and control group(20 piglets). Natural honeybee venom was treated at 0, 3days(castration, tail amputation) and 21days after birth. The acupoints were Hai-men(ST-25), Du-kou(CV-8) and Jiao-chao (GV-1) points at 0 day, the regions of castration and tail ampution at 3 days and Jiao-chao(GV-1) and Bai-hui(GV-20) points at 21days after birth(weaning). Control group was injected 1ml of saline to the same site. Atrophic rhinitis vaccine was injected twice at 24 and 44 days after birth and hog cholera vaccine was also injected twice at 44 and 64 days after birth. Antibody titers against Bordetella bronchiseptica and hog cholera virus were measured by using tube agglutination and ELISA tests at 24, 34, 44, 54 and 74 days after birth. Concentrations of IgG of treated group were 339.52, 366.48, 296.52, 242.06 and 219.06mg/dl at 0, 3, 7, 14 and 21 days after birth, respectively. In contrast, concentrations of IgG in control group were respectively 347.10, 334.14, 243.28, 205.18 and 191.58mg/dl during same periods with treated group. Concentrations of IgG at 0 day was not significantly different between the treated group and control group but treated group were significantly increased by 10.28% at 3 days after birth (P<0.02), 21.88% at 7 days after birth(P<0.01), 18.0% at 14 days after birth(P<0.07) and 14.3% at 21 days after birth(P<0.01). Concentrations of IgA and Ig M were not significantly different. Antibody titers against hog cholera virus were significantly increased by 57.0% at 24 days after birth(P<0.03), 74.6% at 34 days after birth (P<0.006), 48.6% at 44 days after birth(P<0.017), 45.0% at 54 days after birth(P<0.16) and 44.4% at 74 days after birth (P<0.006) in bee venom treated group in comparison with control group. Antibody titers against the Bordetella bronchiseptica was significantly increased in Beevenom treated group as 9.1% (P<0.32) at 24days, 39.7% (P<0.002) at 34days, 31.9% (P<0.02) at 44days, 33.4% (P<0.01) at 54days and 57.3% (P<0.007) at 74 days after birth when compared with those of control group pigs. Collecting together, the results in this study showed that immune responses were increased by treatment of natural honeybee venom to pigs. These results suggested that the treatment of bee venom could be used effectively for the increase of productivity in livestock industry.