• 제목/요약/키워드: Immobilizer system

검색결과 6건 처리시간 0.021초

인크립션 트랜스폰더 타입 이모빌라이져 ECU 소프트웨어 개발 (ECU Software Development for Encryption Transponder-type Immobilizer)

  • 최호준;임동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.669-671
    • /
    • 1998
  • Engine immobilizer is the automobile security system which disables the engine if the secrete code in the transponder embedded in the key knob is not in agreement with the code in ECU of the car. There are many types of immobilizer systems, however, the encryption transponder type system is the most secure system due to the code verification method using an encryption method. As an example of the industry-university cooperation, the software development in the system is introduced in this paper.

  • PDF

이모빌라이저 시스템에서 스마트폰을 이용한 인증 프로토콜 (APSI : A user Authentication Protocol using Smart phone in Immobilizer System)

  • 신미예;정윤수;배우식;이상호
    • 중소기업융합학회논문지
    • /
    • 제4권1호
    • /
    • pp.41-45
    • /
    • 2014
  • 이모빌라이저 시스템은 자동차 키에 저장된 코드와 자동차 엔진 ECU에 저장된 암호코드가 일치하는 경우에만 자동차 시동이 걸리는 차량 도난방지 시스템이다. 이모빌라이저 시스템 자동차의 키 분실 및 차량이 도난당했을 경우 이에 대응하기 위해 스마트 폰 등을 이용 KDC와 KMC를 통하여 사용자 인증을 마친 후 새로운 비밀 번호를 부여받는 모델을 제안한다.

  • PDF

전신 정위 고정장치 제작과 임상효과에 대한 연구 (The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.30-38
    • /
    • 2004
  • 목적: 방사선 치료 시 환자의 움직임을 최대한 고정시켜 줄 수 있으며 환자 자세에 대한 Setup 오차를 감소시키고 환자 전신에 산재한 병소를 위치화하고 좌표화할 수 있는 전신 정위 고정장치 제작과 제작한 고정장치에 대한 고정효과 및 재현성을 나타내는 환자 자세의 Setup 오차를 평가하였다. 대상 및 방법: 자체 제작한 고정장치는 크게 기본판(base plate)과 고정틀(Immobilizer), Vacuum cushion, 벨트로 이루어진다. 기본판은 50${\times}$130${\times}$1 ㎤ 베크라이트로 고정틀은 견고한 아세탈 재질을 사용하여 제작하였다. 초기의 Lax frame의 경우, side panel에 부착되어 있는 좌표계(coordinates)를 기본판 바닥에 radiopaque catheter wire를 사용하여 N 타입으로 새겨서 넣어 위치측정이 가능한 좌표계로 적용할 수 있도록 하였다. 제작된 고정장치에 대한 성능실험으로 방사선 투과율 측정 실험과 가상표적을 부착한 지원 환자를 대상으로 표적에 대한 위치측정실험이 수행되었다. 그리고 CCTV 카메라와 Digital Video Recorder (DVR)를 이용하여 획득된 환자 영상을 Matlab 프로그램으로 환자 자세에 대한 Setup 오차를 분석하였다. 결과: 전신 정위 고정장치는 CT 촬영과 방사선치료 시 사용 가능성에 중점을 두고 제작되었다. 이 고정장치의 구조는 갠트리의 회전각의 변화에 따라 충돌하지 않게 제작되었고 측면으로 경사지게 입사되는 빔의 투과율을 최대화할 수 있게 제작되었다. 고정틀의 고정효과를 높여주는 고정벨트는 입사된 빔의 방향에 방해되지 않게 제작되었다. 고정장치에 대한 방사선 투과율은 10과 21 MV의 에너지에서 95, 95%로 측정되었고 지원 환자에 부착한 가상 표적의 위치는 CT 촬영으로 파악할 수 있었다. Matlab 프로그램으로 분석한 setup 오차는 흉부의 측면과 중심부위에서 3.69$\pm$1.60, 2.14$\pm$0.78 mm이고 복부의 측면과 중심부위에서 7.11$\pm$2.10, 6.54$\pm$2.22 mm이며 여자 환자 경우, 가슴 측면의 Setup 오차는 6.33$\pm$1.55 mm으로 측정되었다. 결론: 전신 정위 고정장치의 제작과 실험을 통해 extra-cranial 암에 대한 방사선수술에서 매우 실용적이고 유용하게 사용될 것으로 사료되며 표적 위치 결정과 환자 고정 도구로서 사용될 것이다. 더 많은 환자 치료자세의 Setup 오차 측정이 수행되면 정확한 환자의 Setup 오차의 결과를 향상시킬 수 있을 것으로 기대된다.

  • PDF

Feasibility Study of Robotics-based Patient Immobilization Device for Real-time Motion Compensation

  • Chung, Hyekyun;Cho, Seungryong;Cho, Byungchul
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.117-124
    • /
    • 2016
  • Intrafractional motion of patients, such as respiratory motion during radiation treatment, is an important issue in image-guided radiotherapy. The accuracy of the radiation treatment decreases as the motion range increases. We developed a control system for a robotic patient immobilization system that enables to reduce the range of tumor motion by compensating the tumor motion. Fusion technology, combining robotics and mechatronics, was developed and applied in this study. First, a small-sized prototype was established for use with an industrial miniature robot. The patient immobilization system consisted of an optical tracking system, a robotic couch, a robot controller, and a control program for managing the system components. A multi speed and position control mechanism with three degrees of freedom was designed. The parameters for operating the control system, such as the coordinate transformation parameters and calibration parameters, were measured and evaluated for a prototype device. After developing the control system using the prototype device, a feasibility test on a full-scale patient immobilization system was performed, using a large industrial robot and couch. The performances of both the prototype device and the realistic device were evaluated using a respiratory motion phantom, for several patterns of respiratory motion. For all patterns of motion, the root mean squared error of the corresponding detected motion trajectories were reduced by more than 40%. The proposed system improves the accuracy of the radiation dose delivered to the target and reduces the unwanted irradiation of normal tissue.

Catechol생산을 위한 Tyrosinase의 안정화 (Stabilization of Tyrosinase for Catechol Production)

  • 박종현;김용환유영제이윤식
    • KSBB Journal
    • /
    • 제9권5호
    • /
    • pp.525-531
    • /
    • 1994
  • 본 연구에서는 tyrosinase 효소반응시에 발생하는 반응 비활성화를 막아 조엽 얀정성을 향상시키는 것을 목적으로 연구를 수행하였다. Quinone에 의해 친핵성 공격을 받는 lysine기를 bifunctional rea gent인 glutaraldehyde로 변형시켜 줌으로써 효소 의 비활성화를 줄일 수 있었다. 또한, 고정화된 효소 를 충진층 반응기에 충진시켜 비활생화를 열으키는 생산물을 연속적으로 제거함으로써 효소의 얀정성을 크게 향상시켰다. 고정화 방법으로는 glass bead를 이용한 담체 가교법을 이용하였으며, 이때 glutaral­d dehyde와 효소의 lysine이 반응하게 되어 qumone 에 의한 친핵성 공격을 받지 않게 되어 안정성이 더욱 향상되 었다. 반응매 질로 borate buffer를 이용하 게되면 catechol과 borate의 복합체 형성으로 catechol에서 qumone으로의 전환이 줄어들게 되어 효소 비활성화가 감소하였다.

  • PDF

3차원 전신 정위 방사선 치료 장치의 개발 (Development of the Whole Body 3-Dimensional Topographic Radiotherapy System)

  • 정원균;이병용;최은경;김종훈;안승도;이석;민철기;박참복;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제10권2호
    • /
    • pp.63-71
    • /
    • 1999
  • 입체조형 치료와 전신 방사선 수술에의 이용을 목적으로 3차원 전신 정위 방사선 치료 장치를 개발하였다. Couch 위에 놓을 수 있는 전신 정위 치료판을 제작하여 방사선 비투과성 카테타 선을 이용하여 치료판 위에 좌표계를 설치하고, MeV-Green(전성 물산, 한국)으로 고정틀을 만들어 환자 자세를 고정시키고, 플라스틱 봉과 봉 지지판을 이용하여 고정틀을 고정하였다. 이러한 설계, 제작으로 입체 조형 치료 등에서 갠트리 회전에 의한 기하학적 제약을 최소화하고 방사선 조사 투과율 이 특정한 방향에서 영향을 받는 문제점을 해소하였다. CT 영상을 통해 치료 표적의 위치를 파악하고 치료판 기준점에 대하여 좌표화하여 모의 치료시와 방사선 치료시의 환자 자세 변화 오차를 줄였다. 3대의 CCTV 카메라를 사용하여 환자 자세 변화를 감지, 수정함으로써 체표변의 외곽선으로 부터 setup 오차를 최소화 할 수 있었다. 치료 효용성을 높이기 위해 이러한 과정을 모니터를 보면서 실시간으로 처리 할 수 있도록 하였고, IDL(Interactive Data Language, RSI, U.S.A.)을 사용하여 image subtraction 방식으로 환자 자세 변화를 가시화하여 오차를 줄이도록 하였다. 내부 장기 움직임에 따른 표적의 움직임을 추적할 목적으로 rotating X-ray 장치를 제작하였다. Landmark 나사를 표적주위 뼈나 표적중심에 삽입하여 이 rotating X-ray 장치를 이용해서 anterior, lateral 두 방향에서 얻은 영상 정보로부터 marker 에 대한 표적의 위치 변화를 가시화 하여 내부 표적의 움직임에 따른 setup 오차를 줄였다. CT 모의치료를 할 수 있도록 IDL 을 이용하여 PC용 모의치료 프로그램을 GUI 환경에서 구현하였고 이 프로그램을 통해서 치료 계획을 위해 CT 에서 수집된 영상정 보를 이용하여 표적을 포함한 장기들의 그래픽 처리, 편집, 전송 등의 작업을 수행하도록 하였다.

  • PDF