• Title/Summary/Keyword: Immobilization method

Search Result 315, Processing Time 0.028 seconds

Immobilization of As and Pb in Contaminated Soil Using Bead Type Amendment Prepared by Iron NanoparticlesImpregnated Biochar (철 나노 입자가 담지된 바이오차 기반 비드 형태 안정화제를 이용한 비소 및 납 오염토양의 안정화)

  • Choi, Yu-Lim;Kim, Dong-Su;Kang, Tae-Jun;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.4
    • /
    • pp.247-257
    • /
    • 2021
  • In this work, Iron Nano-Particles Impregnated BioChar/bead (INPBC/bead) soil amendment was developed to increase biochar's reactivity to As in soil and preventing possible wind loss. Prior to preparation of INPBC/bead, INPBC was produced utilizing lignocellulosic biomass and Fe(III) solution in a hydrothermal method, followed by a calcination process. Then, the bead type amendment, INPBC/bead was produced by cross-linking reaction of alginate with INPBC. FT-IR, XRD, BET, and SEM-EDS analyses were utilized to characterize the as-synthesised materials. The particle size range of INPBC/bead was 1-4 mm, and different oxygen-containing functional groups and Fe3O4 crystalline phase were produced on the surface of INPBC/bead, according to the characterization results. The soil cultivation test was carried out in order to assess the stabilization performance of INPBC/bead utilizing As and Pb-contaminated soil obtained from an abandoned mining location in South Korea. After 4 weeks of culture, TCLP and SPLP extraction tests were performed to assess the stabilization efficacy of the amendment. The TCLP and SPLP findings revealed that raising the application ratio improved stabilizing efficiency. The As stabilization efficiency was determined to be 81.56 % based on SPLP test findings for a 5% in (w/w) INPBC/bead treatment, and the content of Pb in extracts was reduced to the limit of detection. According to the findings of this study, INPBC/bead that can maintain pH of origin soil and minimize wind loss might be a potential amendment for soil polluted with As and heavy metals.

Current Trends in the Treatment of Ankle Ligament Injuries: Analysis of the Korean Foot and Ankle Society (KFAS) Member Survey (족관절 인대 손상 치료 동향: 대한족부족관절학회 회원 설문조사 분석)

  • Cho, Byung-Ki;Cho, Jaeho;Lee, Myoungjin;Lee, Jun Young;Bae, Su-Young;The Academic Committee of Korean Foot and Ankle Society,
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.1
    • /
    • pp.22-29
    • /
    • 2022
  • Purpose: Despite continuous updates of standard treatment guidelines for acute ankle sprain and chronic ankle instability (CAI), in practice preferred treatment protocols vary widely. Based on a Korean Foot and Ankle Society (KFAS) member survey, this study reports current trends in the management of ankle ligament injuries. Materials and Methods: A web-based questionnaire containing 34 questions was sent to all KFAS members in September 2021. Questions mainly addressed clinical experience and preferences for the diagnosis and treatment of ankle ligament injuries. Answers with a prevalence of ≥50% among respondents were considered to reflect tendencies. Results: Eighty-four of the 550 members (15.3%) responded. Answers that showed a tendency were as follows: commonest additional image study (ultrasound), conservative treatment modality (immobilization, oral medication), frequency of surgical treatment (<5 cases per annum), most important factor when deciding on surgical treatment (activity level, e.g., occupation or sport), and commonest surgical procedure (open ligament repair). Answers that showed a tendency for CAI were as follows: most important symptom (repeated sprain, giving way), radiological factors (talar tilt, osteochondral lesion, anterior talar translation), and patient factors (occupation, sports activities, recurrent instability after surgery, etc.). For decision making regarding surgical treatment and method, the most preferred surgical procedure was the modified Broström procedure, and the most common repair technique was suture anchor technique. The following were considered poor prognostic factors; generalized laxity, failed previous surgery, cavovarus, severe mechanical instability, heavy work, obesity, and dissatisfaction after surgery because of residual pain. Conclusion: This study updates information regarding current trends in the management of ankle ligament injuries in Korea, and reveals consensus opinions and variations in approaches to patients with an acute or chronic injury. The divergence of approaches identified indicates the need for further studies to determine standard guidelines and long-term results.

Effect of Impregnation and Modification on Activated Carbon for Acetaldehyde Adsorption (아세트알데하이드 흡착을 위한 활성탄의 첨착 및 개질 효과)

  • Jin Chan Park;Dong Min Kim;Jong Dae Lee
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.472-478
    • /
    • 2023
  • In this study, the acetaldehyde removal characteristics of activated carbon (AC) for air purifier filters were investigated using metal catalysts-impregnation and functional group-modification method. The AC with a high specific surface area(1700 m2/g) and micropores was prepared by KOH activation of coconut charcoal and the efficiency of catalyst and functional group immobilization was examined by varying the drying conditions within the pores after immersion. The physical properties of the prepared activated carbon were analyzed by BET, ICP, EA, and FT-IR, and the acetaldehyde adsorption performances were investigated using gas chromatography (GC) at various impregnation and modified conditions. As the concentration of impregnation solution increased, the amount of impregnated metal catalysts increased, while the specific surface area showed a decreasing trend. The adsorption tests of the metal catalyst-impregnated and functional group-modified activated carbons revealed that excellent adsorption performance in compositions MgO10@AC, CaO10@AC, EU10@AC, and H-U3N1@AC, respectively. The MgO10@AC, which showed the highest adsorption performance, had a breakthrough time of 533.8 minutes and adsorption capacity of 57.4 mg/g for acetaldehyde adsorption. It was found that the nano-sized MgO catalyst on the activated carbon improved the adsorption performance by interacting with carbonyl groups of acetaldehyde.

Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan (전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가)

  • Dong-Oh Shim;Woo-Young Jung;Jae-Kwang Ryu;Cheol-Hong Park;Yoon-Jae Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap. Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap. Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate). Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.

Probing into the optimum preparation and the chemical durability of Sr0.5Zr2(PO4)3-SmPO4 dual-phase ceramics for nuclear waste forms via in-situ synthesis

  • Kunqi Liu;Junxia Wang;Anhang Wu;Jin Wang;Die Liu;Xiaoling Ma
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2174-2181
    • /
    • 2024
  • In this work, Sr0.5Zr2(PO4)3-SmPO4 dual-phase ceramics were prepared via in-situ synthesis process, which is a potential novel nuclear waste form for immobilizing the fission product 90Sr and the trivalent actinide radionuclides in high-level waste (HLW). And the preparation technology, microstructure and chemical durability of Sr0.5Zr2(PO4)3-SmPO4 dual-phase ceramics were systematically investigated. It was confirmed that the optimum microwave-sintering temperature (1050 ℃) and heat preservation time (1.5 h) is estimated by Archimedes method. Besides, the as-prepared samples that were consisted of strontium zirconium phosphate (SrZP) and monazite showed the remarkable densification, in which the two crystalline phases were intermixed well with each other. Meanwhile, the formation and evolution of microstructure was also consistent with the variational rule of Sr0.5Zr2(PO4)3/SmPO4, indicating that there was not mutual reaction during the in-situ synthesis process. The PCT and MCC-1 experimental results demonstrated that the elemental normalized leaching rates of tested samples are all at a low level (LRSr ~10-4 g·m-2·d-1, LRZr ~10-8-10-6 g·m-2·d-1, LRSm ~10-7-10-5 g·m-2·d-1 and LRP ~10-4 g·m-2·d-1). It is indicated that Sr0.5Zr2(PO4)3-SmPO4 dual-phase ceramics possesses excellent chemical durability for HLW disposal.

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.

Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques (유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰)

  • Kim, Young-Bum;Lee, Sang-Rok;Chung, Se-Young;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Purpose: A various find of radiotherapy treatment plans have been made to determine appropriate doses for breasts, chest walls and loco-regional lymphatics in the radiotherapy of breast cancers. The aim of this study was to evaluate the optimum radiotherapy plan technique method by analyzing dose distributions qualitatively and quantitatively. Materials and Methods: To evaluate the optimum breast cancer radiotherapy plan technique, the traditional method(two dimensional method) and computed tomography image are adopted to get breast volume, and they are compared with the three-dimensional conformal radiography (3DCRT) and the intensity modulated radiotherapy (IMRT). For this, the regions of interest (ROI) such as breasts, chest walls, loco-regional lymphatics and lungs were marked on the humanoid phantom, and the computed tomography(Volume, Siemens, USA) was conducted. Using the computed tomography image obtained, radiotherapy treatment plans (XiO 5.2.1, FOCUS, USA) were made and compared with the traditional methods by applying 3DCRT and IMRT. The comparison and analysis were made by analyzing and conducting radiation dose distribution and dose-volume histogram (DVH) based upon radiotherapy techniques (2D, 3DCRT, IMRT) and point doses for the regions of interest. Again, treatment efficiency was evaluated based upon time-labor. Results: It was found that the case of using 3DCRT plan techniques by getting breast volume is more useful than the traditional methods in terms of tumor delineation, beam direction and confirmation of field boundary. Conclusion: It was possible to present the optimum radiotherapy plan techniques through qualitative and quantitative analyses based upon radiotherapy plan techniques in case of breast cancer radiotherapy. However, further studies are required for the problems with patient setup reproducibility arising from the difficulties of planning target volume (PVT) and breast immobilization in case of three-dimensional radiotherapy planning.

  • PDF

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

Decomposition and Nutrient Dynamics of Leaf Litter of Camellia japonica L. in Korea (동백나무(Camellia japonica L.) 낙엽의 분해와 영양원소의 동태)

  • Cha, Sangsub;Lee, Kyung-Eui;Lee, Sang-Hoon;Choi, Moonjong;Shim, Jae Kuk
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.1
    • /
    • pp.110-117
    • /
    • 2016
  • Litter fall is a source of nutrients and carbon transfer in terrestrial ecosystems. Litter decomposition provides nutrients needed for plant growth, sustains soil fertility, and supplies $CO_2$ to the atmosphere. We collected the leaf litter of evergreen broadleaf tree, Camellia japonica L., and carried out a decomposition experiment using the litterbag method in Ju-do, Wando-gun, Korea for 731 days from Dec 25, 2011 to Dec 25, 2013. The leaf litter of C. japonica remained 42.6% of the initial litter mass after experiment. The decay constant (k) of C. japonica leaf litter was $0.427yr^{-1}$. The carbon content of C. japonica leaf litter was 44.6%, and the remaining carbon content during the decomposition tended to coincide with the changes in litter mass. The initial nitrogen and phosphorus content was 0.47% and 324.7 mg/g, respectively. The remaining N in decaying litter increased 1.66-fold in the early decomposition stage, then gradually decreased to 1.18-fold after 731 days. The content of P showed the highest value (1.64-fold of initial content) after 456 days, which then fell to a 1.15-fold after 731 days. The remaining Ca, K, Mg and Na content in C. japonica leaf litter tended to decrease during decomposition. The remaining K showed a remaining mass of 8.9% as a result of rapid reduction. The initial C/N and C/P ratio of C. japonica leaf litter was 94.87 and 1368.5, respectively. However, it tended to decrease as decomposition progressed because of the immobilization of N and P (2.78 and 2.68-fold of initial content, respectively) during the leaf litter decaying. The study results showed that N and P was immobilized and other nutrients was mineralized in C. japonica leaf litter during experimental period.

Evaluation of Fate of $NH_4{^+}$ of Condensed Molasses Solubles(CMS) in Soil Using by $^{15}N$-Tracer Method (중질소 추적자법을 이용한 Condensed Molasses Solubles(CMS) 함유 $NH_4{^+}$의 토양 중 행동 연구)

  • Lee, Sang-Mo;Choi, Woo-Jung;Yun, Seok-In;Choi, Young-Dae;Ro, Hee-Myong;Park, Jee-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.35 no.2
    • /
    • pp.69-76
    • /
    • 2002
  • To study the behavior of $NH_4{^+}$ of CMS (condensed molasses solubles) in soil, a laboratory incubation experiment was conducted during a period of up to 21 days at $25^{\circ}C$. The $NH_4{^+}$ of CMS was labeled with $^{15}N$ and was applied to water-unsturated and water-saturated conditions. Soil pH was gradually decreased from 6.1 to 5.4 under unsaturated condition. However, soil pH was increased to 6.5 within 2 days under saturated condition and then was constant. The concentration of ammonium was decreased 3 times faster under unsaturated condition than under saturated condition. The concentration of nitrate was increased from 17.4 to $155.4mg\;kg^{-1}$ under unsaturated condition. But concentration of nitrate was kept with low(below $8.0mg\;kg^{-1}$) under saturated condition. During the incubation, 52.4% of $^{15}NH_4{^+}$ applied was existed in the form of $NO_3{^-}$ by nitrification under unsaturated condition. Most of applied nitrogen was immobilized within 4 days of incubation. On 21 days of the incubation the percentage of immobilized nitrogen derived from $^15NH_4{^+}$(NDFA) was 19.6% under unsaturated condition and 17.0% under saturated condition. The percentage of unaccounted N, which was lost by denitrification, was 28.4% under unsturated condition and 67.6% under saturated condition.