• Title/Summary/Keyword: Immediately loading

Search Result 98, Processing Time 0.021 seconds

Damage zone induced by quasi-static gas pressure during blasting (준정적인 발파 가스압에 의한 암반의 손상 영역 예측)

  • Sim, Young-Jong;Cho, Gye-Chun;Kim, Hong-Taek
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1409-1416
    • /
    • 2010
  • It is essential to predict a blasting-induced excavation damage zone (EDZ) beyond the proposed excavation line of a tunnel because the unwanted damage area requires extra support system for tunnel safety. Complicated blasting process which may hinder a proper characterization of the damage zone can be effectively represented by two loading mechanisms. The one is a dynamic impulsive load generating stress waves outwards immediately after detonation. The other is a gas pressure that remains for a relatively long time. Since the gas pressure reopens up the arrested cracks and continues to extend some cracks, it contributes to the final formation of EDZ induced by blasting. This paper presents the simple method to evaluate EDZ induced by gas pressure during blasting in rock. The EDZ is characterized by analyzing crack propagation from the blasthole. To do this, a model of the blasthole with a number of radial cracks of equal length in an infinite elastic plane is considered. In this model, the crack propagation is simulated by using three conditions, the crack propagation criterion, the mass conservation of the gas, and the adiabatic condition. As a result, the stress intensity factor of the crack generally decreases as crack propagates from the blasthole so that the length of the crack is determined. In addition, the effect of rock properties, initial number of cracks, and the adiabatic exponent are investigated.

  • PDF

A COMPARATIVE STUDY ON THE FLEXIBILITY OF THE WROUGHT WIRE CLASPS (가공선 크라스프의 가요성에 관한 비교 연구)

  • Eom, Tae-Wan;Chang, Ik-Tae;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.261-270
    • /
    • 1989
  • Bend test is one of the methods comparing the physical properties of the clasp wires. The type of bend test used in this investigation was the cantilever loading of a wrought wire. The purpose of this study was to compare the flexibility of a number of commonly used clasp wires, in according to gauge, alloy and heat treatment, under specific condition of load and deflection. Seven noble and one base metal wires were tested under three conditions as follows: (1) as received, (2) quenched (placed in an over at $700^{\circ}C$ for ten minutes and immediately quenched in water at room temperature.), (3) oven cooled (quencned as described, then placed in an oven at $450^{\circ}C$ for two minutes and uniformly slowly cooled to $250^{\circ}C$ in thirty minutes.) The basic test specimen consists of a sample 25 mm in length and 19, 18 gauge in diameter (17 gauge also in two alloys), and the wire was loaded in the form of straight cantilever beams. Force at 0.25 mm (0.01 inch) and 0.5 mm (0.02 inch) deflections for all samples were recorded. The results were as follows ; 1. Ticonium was least flexible and No. 2 was most flexible in according to gauge, alloy and heat treatment. 2. In most of precious wrought wire, the flexibility was increased, but there was no statistically significant differences between as-received and softened condition. 3. There was no statistically differences between as-received and hardened condition. 4. For each alloy, there were statistically significant differences in flexibility due to clasp diameter.

  • PDF

Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength

  • Ha, Seung-Ryong;Yang, Jae-Ho;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.14-17
    • /
    • 2010
  • PURPOSE. The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. MATERIAL AND METHODS. One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (${\phi}\;4\;mm\;{\times}\;6\;mm$) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheff$\acute{e}$ test and independent sample t test ($\alpha\;=\;0.05$). RESULTS. Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. CONCLUSION. The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.

Overall damage identification of flag-shaped hysteresis systems under seismic excitation

  • Zhou, Cong;Chase, J. Geoffrey;Rodgers, Geoffrey W.;Xu, Chao;Tomlinson, Hamish
    • Smart Structures and Systems
    • /
    • v.16 no.1
    • /
    • pp.163-181
    • /
    • 2015
  • This research investigates the structural health monitoring of nonlinear structures after a major seismic event. It considers the identification of flag-shaped or pinched hysteresis behavior in response to structures as a more general case of a normal hysteresis curve without pinching. The method is based on the overall least squares methods and the log likelihood ratio test. In particular, the structural response is divided into different loading and unloading sub-half cycles. The overall least squares analysis is first implemented to obtain the minimum residual mean square estimates of structural parameters for each sub-half cycle with the number of segments assumed. The log likelihood ratio test is used to assess the likelihood of these nonlinear segments being true representations in the presence of noise and model error. The resulting regression coefficients for identified segmented regression models are finally used to obtain stiffness, yielding deformation and energy dissipation parameters. The performance of the method is illustrated using a single degree of freedom system and a suite of 20 earthquake records. RMS noise of 5%, 10%, 15% and 20% is added to the response data to assess the robustness of the identification routine. The proposed method is computationally efficient and accurate in identifying the damage parameters within 10% average of the known values even with 20% added noise. The method requires no user input and could thus be automated and performed in real-time for each sub-half cycle, with results available effectively immediately after an event as well as during an event, if required.

Influence of late removal after treatment on the removal torque of microimplants

  • Kim, Ho-Jin;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.52 no.3
    • /
    • pp.201-209
    • /
    • 2022
  • Objective: To compare the removal torque of microimplants upon post-use removal and post-retention removal and to assess the influencing factors. Methods: The sample group included 241 patients (age, 30.25 ± 12.2 years) with 568 microimplants. They were divided into the post-use (microimplants removed immediately after use or treatment) and post-retention (microimplants removed during the retention period) removal groups. The removal torque in both groups was assessed according to sex, age, placement site and method, and microimplant size. Pearson correlation and multiple linear regression analyses were performed for evaluating variables influencing the removal torque. Results: The mean period of total in-bone stay of microimplants in the post-retention removal group (1,237 days) was approximately two times longer than that in the post-use removal group (656.28 days). The removal torques in the post-retention removal group (range, 4-5 N cm) were also higher than those in the post-use removal group. The mandible and pre-drilling groups demonstrated higher placement and removal torques than did the maxilla and no-drilling groups, respectively. In the no-drilling post-use removal group, the placement torque and microimplant length positively correlated with the removal torque. In the post-retention removal group, unloading in-bone stay period and microimplant diameter positively correlated with the removal torque in the no-drilling and pre-drilling methods, respectively. Conclusions: The removal torques differed according to the orthodontic loading and removal time of microimplants. With prolonged retention of microimplants inserted using the no-drilling method, the removal torque was clinically acceptable and positively correlated with the unloading in-bone stay period.

A Study on the Tendency of Fugitive Dust for Environmental Maintenance at the Aggregate Unloading Site of Ready-mixed Concrete Plants (레미콘 플랜트의 골재하차장 환경 유지관리를 위한 비산먼지 발생 경향에 관한 연구)

  • Cho, Hyun-Woo;Shin, Hong-Chul;Chung, Yoon-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.103-111
    • /
    • 2022
  • Fine dust can cause serious problems to human health, and fugitive dust generated at construction sites is one of the main sources of fine dust in Korea. However, monitoring of the amount of fugitive dust generated at the ready-mixed concrete plant site is not performed, and only passive monitoring methods are partially applied in the field. Since it is impossible to control fugitive dust after it is exposed to the air, it is very important to suppress the occurrence or to remove it immediately at the stage of occurrence. Therefore, after identifying the characteristics through real-time monitoring in the fugitive dust generation stage, systematic management is required for suppressing or removing scattering dust in the field. In this study, the scattering dust generation characteristics were analyzed by measuring the particle mass concentration(PMC) of Fugitive dust generated at the aggregate unloading site of the ready-mixed concrete plant in real-time.

Health assessment of RC building subjected to ambient excitation : Strategy and application

  • Mehboob, Saqib;Khan, Qaiser Uz Zaman;Ahmad, Sohaib;Anwar, Syed M.
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.185-201
    • /
    • 2022
  • Structural Health Monitoring (SHM) is used to provide reliable information about the structure's integrity in near realtime following extreme incidents such as earthquakes, considering the inevitable aging and degradation that occurs in operating environments. This paper experimentally investigates an integrated wireless sensor network (Wi-SN) based monitoring technique for damage detection in concrete structures. An effective SHM technique can be used to detect potential structural damage based on post-earthquake data. Two novel methods are proposed for damage detection in reinforced concrete (RC) building structures including: (i) Jerk Energy Method (JEM), which is based on time-domain analysis, and (ii) Modal Contributing Parameter (MCP), which is based on frequency-domain analysis. Wireless accelerometer sensors are installed at each story level to monitor the dynamic responses from the building structure. Prior knowledge of the initial state (immediately after construction) of the structure is not required in these methods. Proposed methods only use responses recorded during ambient vibration state (i.e., operational state) to estimate the damage index. Herein, the experimental studies serve as an illustration of the procedures. In particular, (i) a 3-story shear-type steel frame model is analyzed for several damage scenarios and (ii) 2-story RC scaled down (at 1/6th) building models, simulated and verified under experimental tests on a shaking table. As a result, in addition to the usual benefits like system adaptability, and cost-effectiveness, the proposed sensing system does not require a cluster of sensors. The spatial information in the real-time recorded data is used in global damage identification stage of SHM. Whereas in next stage of SHM, the damage is detected at the story level. Experimental results also show the efficiency and superior performance of the proposed measuring techniques.

Mandibular implant supported overdentures with two different mini-implant systems: A case report (두 종류의 임플란트 시스템을 이용한 하악의 미니-임플란트지지 피개의치 수복 증례)

  • Park, Jin-Hong;Lee, Jeong-Yol;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.267-272
    • /
    • 2016
  • This case report describes the treatment of two fully edentulous patients with mini-implant overdentures using different implant systems on narrow mandibular alveolar bone ridge. They were complaining about discomfort and pain wearing mandibular conventional complete dentures caused by insufficient retention. Each patient received four miniimplants in the interforaminal area of the mandible using the non-submerged flapless surgical approach. One-body type implant (Slimline, Dentium, Seoul, Korea) was used for a patient and loaded immediately after surgery. Metal housings of O-ring were attached by direct technique. For the other patient, two-piece type implant (LODI, Zest Anchors, Escondido, CA, USA) was used and impressions were made for attachment connection of the Locator's metal housings after 8 weeks of surgery. Within this case report, mandibular miniimplant overdentures using different implant systems showed improvement of patient satisfaction with favorable peri-implant tissue response 6 months after attachment connection. However, long-term follow-up is needed for further evaluation.

Deep Sedation for Palate Alginate Impression Procedure in a Post-Fontan Procedure Patient with Mental Retardation (Fontan 수술을 받은 정신지체 소아에서 인상채득을 위해 시행한 깊은 진정)

  • Lee, Jung-Man;Seo, Kwang-Suk;Kim, Hyun-Jeong;Shin, Soon-Young;Shin, Teo-Jeon
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.12 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • The Fontan operation is a heart operation used to treat complex congenital heart defects like tricuspid atresia, hypoplastic left heart syndrome, pulmonary atresia and single ventricle. A single ventricle is dedicated to pumping oxygenated blood to the systemic circulation and the entire systemic venous return reaches the pulmonary arterial system without the direct influence of a pumping chamber. In the patient with Fontan operation, it is important to achieve adequate pulmonary blood flow and cardiac output in anesthetic management. In this case, a 10-year-old boy (19.6 kg, 114 cm) with cleft palate, cerebral palsy and severe mental retardation, who underwent a Fontan operation when he was 4 years old, was presented for deep sedation. Because he was suffering from eating disorder with cleft palate, the orthodontist and the plastic surgeon planned to insert intraoral orthodontic device before cleft palate repair. But it was impossible to open his mouth for alginate impression procedure. After careful pre-anesthesia evaluation we planned to administer deep sedation with propofol infusion. After Intravenous catheter insertion, we started propofol intravenous infusion with the formula of a loading dose of 1.0 mg/kg followed by an infusion rate of 6.0 mg/kg/hr with syringe pump. His blood pressure was remained around 80/40 mmHg after loss of consciousness, but he could not maintain his airway patent. So we lowered the infusion rate to 3.0 mg/kg/hr, immediately. The oxygen saturation was maintained above 95% with nasal oxygen supply, and blood pressure was maintained around 100-80/60-40 mmHg. After the sedation of 110 minutes with propofol (the infusion rate to 3.0-5.0 mg/kg/hr), he fully regained consciousness, and was discharged without complication after 1 hour observation. In case of post-Fontan patient, intravenous deep sedation with propofol was safe and effective method of behavioral management during dental treatment.

Study on the Durability of Composite Tilting Pad Journal Bearing for Turbo Compressor System under Oil-cut Situation (터보 컴프레셔용 복합재료 틸팅 패드 저널 베어링의 오일 공급 중단 상황에서의 내구성 연구)

  • Choe, Kang-Yeong;Jung, Min-Hye;You, Jun-Il;Song, Seung-A;Kim, Seong-Su
    • Composites Research
    • /
    • v.29 no.3
    • /
    • pp.111-116
    • /
    • 2016
  • The tilting pad journal bearing for the turbo compressor application has a role to support high speed and heavy loading rotor. White metal has been widely used for the bearing material but the conventional bearing is immediately suspended and induces serious serious damage to the rotor under the unexpected oil cut situation or the insufficient oil film formation. The carbon fiber reinforced composite having high specific stiffness, specific strength and excellent tribological characteristics can solve these seizure problems. In this work, the study on the durability of high thermal resistance carbon fiber/epoxy composite tilting pad journal bearing under oil cut situation was conducted. The material properties of the composite materials including tensile, compressive and interlaminar properties were measured at room and high temperature of oil cut situation. To investigate the possibility of failure of composite tilting pad journal bearing under oil cut situation, the stress distribution of the composite bearing was analyzed via finite element analysis and the Tsai-Wu Failure index was calculated. To verify the failure analysis results, the oil cut tests for the composite tilting pad journal bearing were conducted using industrial test bench.