• 제목/요약/키워드: Immediately loading

검색결과 98건 처리시간 0.027초

Effects of implant tilting and the loading direction on the displacement and micromotion of immediately loaded implants: an in vitro experiment and finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • 제47권4호
    • /
    • pp.251-262
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of implant tilting and the loading direction on the displacement and micromotion (relative displacement between the implant and bone) of immediately loaded implants by in vitro experiments and finite element analysis (FEA). Methods: Six artificial bone blocks were prepared. Six screw-type implants with a length of 10 mm and diameter of 4.3 mm were placed, with 3 positioned axially and 3 tilted. The tilted implants were $30^{\circ}$ distally inclined to the axial implants. Vertical and mesiodistal oblique ($45^{\circ}$ angle) loads of 200 N were applied to the top of the abutment, and the abutment displacement was recorded. Nonlinear finite element models simulating the in vitro experiment were constructed, and the abutment displacement and micromotion were calculated. The data on the abutment displacement from in vitro experiments and FEA were compared, and the validity of the finite element model was evaluated. Results: The abutment displacement was greater under oblique loading than under axial loading and greater for the tilted implants than for the axial implants. The in vitro and FEA results showed satisfactory consistency. The maximum micromotion was 2.8- to 4.1-fold higher under oblique loading than under vertical loading. The maximum micromotion values in the axial and tilted implants were very close under vertical loading. However, in the tilted implant model, the maximum micromotion was 38.7% less than in the axial implant model under oblique loading. The relationship between abutment displacement and micromotion varied according to the loading direction (vertical or oblique) as well as the implant insertion angle (axial or tilted). Conclusions: Tilted implants may have a lower maximum extent of micromotion than axial implants under mesiodistal oblique loading. The maximum micromotion values were strongly influenced by the loading direction. The maximum micromotion values did not reflect the abutment displacement values.

대형 프레스용 자동화 시스템 개발 (Development of Automation System for Press Line)

  • 김순철;권용수;한상동;노태정;안병규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.806-809
    • /
    • 1996
  • The present development relates to an apparatus for loading or unloading a workpiece, and more particularly, to an apparatus for loading or unloading a workpiece from a press die or supplier An apparatus for loading or unloading a workpiece has been installed in a press in order to load or unload a workpiece from a press die. There has been known such a loading or unloading apparatus as the apparatus can feed a workpiece in not only the horizontal direction but also in the vortical direction. Press working system in automotive factories are now switching over to a transfer press work ing system. The current problem to be sieved immediately is to automate the existing manual press lines for the manpower saving and speedy production. “Automation system for press line”has just been developed to meet the above trend. The loader and unloader are development under the design concept for high performance, easy control and operational safety to meet the more extensive.

  • PDF

완전 무치악에서 즉시 부하시와 표준 부하시 임플란트 생존율에 대한 비교 분석: 후향적 연구 (Comparative analysis of immediate functional loading and conventional loading about implant survival rate in the completely edentulous: Retrospective study)

  • 서현수;박준우;홍순민;이석련
    • 대한치과의사협회지
    • /
    • 제52권12호
    • /
    • pp.771-782
    • /
    • 2014
  • Introduction: This study researched the clinical application of immediate functional loading technique about implant survival rate in the completely edentulous and suggested our protocol about surgical & prosthetic procedure. Materials and methods: 32 consecutive patients participated in this study. A total of 242 implants were inserted. In test group, 144 implants were inserted in 19 patients with immediate functional loading with occlusal contact. In control group, 98 implants were inserted in 13 patients and conventional loading was done after 4~6 months. Result: In the immediately loaded implants group, overall cumulative survival rate was 98.6%.

Changes in the fractal dimension of peri-implant trabecular bone after loading: a retrospective study

  • Mu, Teh-Jing;Lee, Dong-Won;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • 제43권5호
    • /
    • pp.209-214
    • /
    • 2013
  • Purpose: To assess bony trabecular changes potentially caused by loading stress around dental implants using fractal dimension analysis. Methods: Fractal dimensions were measured in 48 subjects by comparing radiographs taken immediately after prosthesis delivery with those taken 1 year after functional loading. Regions of interest were isolated, and fractal analysis was performed using the box-counting method with Image J 1.42 software. Wilcoxon signed-rank test was used to analyze the difference in fractal dimension before and after implant loading. Results: The mean fractal dimension before loading ($1.4213{\pm}0.0525$) increased significantly to $1.4329{\pm}0.0479$ at 12 months after loading (P<0.05). Conclusions: Fractal dimension analysis might be helpful in detecting changes in peri-implant alveolar trabecular bone patterns in clinical situations.

편마비환자의 환측하지 체중부하율 향상을 위한 효과적인 외적 되먹임 빈도 (Effective Frequency of External Feedback for Increasing the Percentage of Body Weight Loading on the Affected Leg of Hemiplegic Patients)

  • 노미혜;이충휘;조상현;김태우
    • 한국전문물리치료학회지
    • /
    • 제5권3호
    • /
    • pp.1-10
    • /
    • 1998
  • In motor learning, the relative frequency of external feedback is the proportion of external feedback presentations divided by the total number of practice trials. In earlier studies, increasing the percentage of body weight loading on the affected leg of hemiplegic patients, external feedback was continuously produced as the patient attempted to perform a movement. This feedback was produced to enhance the learning effect. However, recent studies in nondisabled populations have suggested that compared with 100% relative frequency conditions, practice with lower relative frequencies is more effective. My study compared the effect of 100% relative frequency conditions with 67% relative frequency conditions to determine what effect they exerted on motor learning for increasing the percentage of body weight loading on the affected lower limbs of patients with hemiplegia. Twenty-four hemiplegic patients were randomly assigned to one of two experimental groups. Each group practiced weight transfer motor learning on a machine. During practice, visual feedback was offered to all subjects. The experiment was carried out with full visual feedback for patients in group one but only 67% visual feedback for patients in group two. The percentage of loading on the affected leg was recorded four times: before learning (baseline value), immediately after learning, 30 minutes after learning, 24 hours after learning. The results were as follows: 1. In the 100% visual feedback group, the percentage of loading on the affected leg increased significantly in all three testing modes over the baseline value. 2. In the 67% visual feedback group, the percentage of loading on the affected leg increased significantly in all three measurements. 3. Immediately after learning, the learning effect was not significantly different between the two groups, but was significantly greater after both the 30 minutes delay and the 24 hours period. These results suggest that the 33% reduction in the provision of visual feedback may enhance the learning effect of increasing the percentage of body weight loading on the affected leg in patients with hemiplegia.

  • PDF

Effects of orthodontic force on root surface damage caused by contact with temporary anchorage devices and on the repair process

  • Guler, Ozge Celik;Malkoc, Siddik
    • 대한치과교정학회지
    • /
    • 제49권2호
    • /
    • pp.106-115
    • /
    • 2019
  • Objective: This study aimed to evaluate the effects of force loading on root damage caused by contact with temporary anchorage devices (TADs) during orthodontic treatment and to examine the repair process 4, 8, and 12 weeks after TAD contact by micro-computed tomography (CT). Methods: We enrolled 42 volunteers who required bilateral upper first premolar extractions. The experimental study design was as follows. For both first premolars, cantilever springs were placed, and then TADs were immediately inserted between the premolars of all volunteers. According to the removal order of the appliances, the participants were divided into the TAD group (Group T: n = 21, only TAD removal) and the spring group (Group S: n = 21, only spring removal). A splitmouth design was adopted in both groups as follows. For each volunteer, the left premolars were extracted 4, 8, or 12 weeks after TAD-root contact. The right premolars were extracted immediately after contact in both groups (Groups T-C and S-C) and used as positive controls. Resorption volumes and numbers of craters were determined by micro-CT. Results: The numbers of resorption craters were higher in Group T than in Group S at 8 and 12 weeks (p < 0.01). Crater volumes were higher in Group T than in Group S at 4 and 12 weeks (p < 0.01, both). Conclusions: Root injury was not completely repaired 12 weeks after root-TAD contact, even when the TADs were removed in cases of continuous force application.

Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis

  • Magat, Guldane;Oncu, Elif;Ozcan, Sevgi;Orhan, Kaan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권1호
    • /
    • pp.41-49
    • /
    • 2022
  • Objectives: We compared changes in fractal dimension (FD) and grayscale value (GSV) of peri-implant alveolar bone on digital panoramic radiography (DPR) and cone-beam computed tomography (CBCT) immediately after implant surgery and 12 months postoperative. Materials and Methods: In this retrospective study, 16 patients who received posterior mandibular area dental implants with CBCT scans taken about 2 weeks after implantation and one year after implantation were analyzed. A region of interest was selected for each patient. FDs and GSVs were evaluated immediately after implant surgery and at 12-month follow-up to examine the functional loading of the implants. Results: There were no significant differences between DPR and CBCT measurements of FD values (P>0.05). No significant differences were observed between FD values and GSVs calculated after implant surgery and at the 12-month follow-up (P>0.05). GSVs were not correlated with FD values (P>0.05). Conclusion: The DPR and reconstructed panoramic CBCT images exhibit similar image quality for the assessment of FD. There were no changes in FD values or GSVs of the peri-implant trabecular bone structure at the 12-month postoperative evaluation of the functional loading of the implant in comparison to values immediately after implantation. GSVs representing bone mass do not align with FD values that predict bone microstructural parameters. Therefore, GSVs and FDs should be considered different parameters for assessing bone quality.

면외하중을 받는 상이한 직교 이방성 평면내의 평행균열 (Parallel Crack in Bonded Dissimilar Orthotropic Planes Under Out-of-Plane Loading)

  • 최성렬;권용수;채영석
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.170-180
    • /
    • 1995
  • A parallel crack in bonded dissimilar orthotropic planes under out-of-plane loading is analyzed. The problem is formulated by Fourier integral transforms, and reduced to a pair of dual integral equations. By solving the integral equations, the asymptotic stress and displacement fields near the crack tip are determined in closed form, from which the stress intensity factor and energy release rate are obtained. Discontinuity in the stress intensity factor as the distance ratio h/a of the parallel crack approaches zero is found, while the energy releas rate is shown to be continuous at h/a = 0. This information can immediately be used to generate the stress intensity factor for the parallel crack near the interface. By employing "the maximum energy release rate criterion", it could be shown in the case of no existing crack initially that the parallel crack is formed far from the interface for the more compliant material, while it is formed close to the interface for the stiffer material. material.

탄점성압밀방정식을 이용한 점성토의 일차원 압밀 해석에 관한 연구 (One-dimensional consolidation analysis of clayey soils based on elasto-viscous liquid model)

  • 염혜선;김지용;정승용;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.689-694
    • /
    • 2000
  • The traditional concept after Terzaghi was that consolidation was the dissipation process of pore water pressure compatible to external loading which was generated immediately after the loading. However, a theory of one-dimensional consolidation based on elasto-viscous liquid model proposed by Yoshikuni(1994) explained that the process of primary and secondary consolidation was considered to be not a simple process of dissipation of pore water pressure but a simultaneous process of dissipation and generation by external loading. This study attempts to demonstrate general consolidation behaviour of clayey soils including effects of consolidation history, load increment and thickness of cohesive layer by one-dimensional Finite Difference Method(F.D.M) analysis from the viewpoint of elasto-viscous consolidation theory.

  • PDF

혼합모드 단일과대하중 하의 피로균열 전파거동에 관한 실험적 연구 (An Experimental Study on the Fatigue Crack Propagation Behavior Under Mixed-Mode Single Overload)

  • 송삼홍;이정무;홍석표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.119-124
    • /
    • 2003
  • In this study, retardation behavior of fatigue crack under single overloading of the mixed mode I+II state was experimentally investigated. To produce single overload in the mixed mode I+II state, the compact tension shear (CTS) specimen and loading device were used. The propagation tests for fatigue crack were performed under mode I loading overloading afterwards. We examined the observed deformation aspects, variation of fatigue life and crack propagation rate, and the aspects of retardation behavior from tests. The retardation effect of mixed-mode single overload on fatigue crack propagation behavior was smaller than that of mode I single overload. It has been confirmed that the retardation behavior did not immediately appear and the retardation length was short when the component of mixed-mode overload was changed.

  • PDF