• 제목/요약/키워드: Immediate implants

검색결과 181건 처리시간 0.031초

The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • 제46권3호
    • /
    • pp.152-165
    • /
    • 2016
  • Purpose: This study investigated the effects of bone density and crestal cortical bone thickness at the implant-placement site on micromotion (relative displacement between the implant and bone) and the peri-implant bone strain distribution under immediate-loading conditions. Methods: A three-dimensional finite element model of the posterior mandible with an implant was constructed. Various bone parameters were simulated, including low or high cancellous bone density, low or high crestal cortical bone density, and crestal cortical bone thicknesses ranging from 0.5 to 2.5 mm. Delayed- and immediate-loading conditions were simulated. A buccolingual oblique load of 200 N was applied to the top of the abutment. Results: The maximum extent of micromotion was approximately $100{\mu}m$ in the low-density cancellous bone models, whereas it was under $30{\mu}m$ in the high-density cancellous bone models. Crestal cortical bone thickness significantly affected the maximum micromotion in the low-density cancellous bone models. The minimum principal strain in the peri-implant cortical bone was affected by the density of the crestal cortical bone and cancellous bone to the same degree for both delayed and immediate loading. In the low-density cancellous bone models under immediate loading, the minimum principal strain in the peri-implant cortical bone decreased with an increase in crestal cortical bone thickness. Conclusions: Cancellous bone density may be a critical factor for avoiding excessive micromotion in immediately loaded implants. Crestal cortical bone thickness significantly affected the maximum extent of micromotion and peri-implant bone strain in simulations of low-density cancellous bone under immediate loading.

Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례 (Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report)

  • 성현미;설경희;강선우;김정한
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.131-139
    • /
    • 2024
  • 무치악 환자에서 임플란트를 이용한 보철치료는 임플란트 고정성 보철, 임플란트 융합 국소 의치, 하이브리드 보철물, 임플란트 유지 및 지지 피개의치 등의 다양한 방법이 있다. 본 증례에서는 중등도 이상의 만성 치주염에 이환 되어 전악 발치가 필요한 환자에서 computer guided surgery를 이용하여 계획된 위치에 임플란트를 식립하였다. 상악은 불량한 골질로 초기고정력이 충분하지 않아 지연 부하를 시행하였고 골 유착 기간 동안 임시 의치를 사용하였다. 하악은 안정적인 초기 고정을 얻어 즉시 부하를 이용하여 환자의 불편감을 감소시켰다. 임플란트 일차 안정은 즉시 부하를 얻기 위해 가장 중요한 요소로 여겨지기 때문에 수술 전 반드시 임상적, 방사선학적 평가를 통해 잔존 치조골 양 및 골질을 파악해야 한다.

교정력 부하시기에 따른 교정용 미니 임플란트의 안정성 (The effect of loading time on the stability of mini-implant)

  • 이승연;차정열;윤태민;박영철
    • 대한치과교정학회지
    • /
    • 제38권3호
    • /
    • pp.149-158
    • /
    • 2008
  • 본 연구는 미니 임플란트 식립 후 교정력 부하시기와 관련하여 임플란트 주위골의 치유과정을 조사하였다. 성견 8마리의 하악 협측골에 교정용 미니 임플란트(ORLUS, Ortholution CO, Korea) 48개를 식립한 후 교정력을 주지 않은 대조군과 식립 후 즉시 교정력을 준 즉시 부하군, 그리고 식립 후 3주간의 치유기간을 두고 교정력을 준 지연 부하군으로 나누어 각각의 군에 대해 3주, 6주, 12주가 경과된 시점에 임플란트 주위골의 변화를 조직 계측학적으로 관찰하였다. 골 접촉률은 즉시 부하군에서 시기에 따른 유의한 변화가 없었으며 지연 부하군은 3주에 비해 12주에서 유의하게 증가하였다(p<0.05). 각 시점에서 군간의 골 접촉률을 비교했을 때 12주째 지연 부하군이 즉시 부하군 보다 유의하게 높았다(p<0.05). 골 면적비율은 즉시 부하군의 경우, 시기에 따른 유의한 변화가 없었으며, 지연 부하군과 대조군은 6주에 비해 12주째 유의한 증가를 보였으며 (p<0.05), 12주째 실험군 간에 유의한 차이는 관찰되지 않았다(p>0.05). 동요도는 12주째 즉시 부하군과 지연 부하군 간에 유의한 차이는 없었다(p>0.05). 위의 결과에서 즉시 부하가 self drilling형 미니 임플란트 주위골의 안정성에 부정적인 영향을 주지 않았으므로 식립 즉시 교정력을 부여하여 사용하는 데 임상적으로 문제가 없을 것으로 판단된다.

당뇨쥐 상악에서 발치후 즉시 식립 임플란트 주위골의 방사선 골밀도 (Radiographic Bone Density Around Immediately Placed Titanium Implant on the Extraction Socket of Diabetic and Insulin-Treated Rat Maxilla)

  • 박건현;박수현;이성휘;표성운
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권5호
    • /
    • pp.389-395
    • /
    • 2010
  • Purpose: Although it is generally accepted that patients with controlled diabetes have similar rates of success for dental implants as healthy individuals, the use of dental implants in diabetic patients is controversial. In addition, the impact of diabetes on the healing of bone associated with immediately place dental implants is not completely understood. The purpose of this study was to measure bone response to implants radiologically in uncontrolled and insulin-controlled diabetic rats. Materials and Methods: Twenty rats were divided into control, insulin-treated and diabetic groups. The rats received streptozotocin (60 mg/kg) to induce diabetes; animals in the insulin-treated group also received three units of subcutaneous slow-release insulin. Two titanium implants ($1.2{\times}3$ mm) were placed in the extraction socket of the maxillary first molars of the animals and were harvested at 3 days, 1, 2 and 4 weeks. The bone density was measured by digital radiography using gray-level analysis (histogram) in the regions of interest (ROI) at four points: two mesial and two distal to both sides of the implant. Results: The results showed that the osseointegration of the implants was impaired in the diabetic rats compared to the control and the insulin-treated rats. The radiographic evidence demonstrated marked destruction of bone around the implants in the diabetic group. Both the control and the insulin-treated groups had a significantly higher bone density on radiograph than the diabetic group from the 1 week of the experiment (P<0.05 for each comparison). Conclusion: The present study revealed that the immediate placement of titanium implants in the maxilla of diabetic rat lead to delay in the maturation of bone adjacent to implants. It is expected that the reduced predictability of success of immediate implantation in patient with the uncontrolled diabetes.

즉시 식립 임플란트 - 합병증을 줄이기 위한 고려 사항 (Considerations for minimizing complications in immediate placement of dental implant)

  • 박관수
    • 대한치과의사협회지
    • /
    • 제58권9호
    • /
    • pp.564-572
    • /
    • 2020
  • Implant treatment has long been established as the main stream for the recovery of lost teeth. Implant therapy, which began to be practiced under the concept of osseointegration, was performed on the completely healed bone, but implant placement immediately after extraction, which began to be introduced in the 1970s, began to become a widely used treatment modality since the 2000s. However, as with all other procedures, immediate implant placement is not omnipotent. If you are obsessed with the obsession that you need to provide quicker implant treatment to the patients, and if you do it as if you are being chased by time, it is the immediate implant placement that can lead to various embarrassing situations. In this article, to reduce complications, the author will look at some issues that need to be considered when placing implants immediately after extraction.

  • PDF

실리콘 보형물을 이용한 즉시 유방재건 후 발생한 Mondor's Disease 치험례 (Mondor's Disease after Immediate Breast Reconstruction with Silicone Implant)

  • 선상훈;이택종
    • Archives of Plastic Surgery
    • /
    • 제37권1호
    • /
    • pp.87-90
    • /
    • 2010
  • Purpose: Mondor's disease is commonly known as a benign breast condition after augmentation mammaplasty, and some authors have also reported its association with other breast surgeries such as reduction mammaplasty or axillary lymph node biopsy. Here we report two cases of Mondor's disease after immediate breast reconstruction with silicone implant. Methods: Two women, 51-year-old and 36-year-old, underwent immediate breast reconstruction with silicone implants after nipple-areolar skin-sparing mastectomy. Results: Subcutaneous cord-like firm lesion appeared on upper abdomen, axillary area following surgery. The lesion was painless and spontaneously subsided with no medications. Conclusion: To our knowledge, this is the first report of Mondor's disease developed after immediate breast reconstruction using silicone implant.

Effect of loading time on marginal bone loss around hydroxyapatite-coated implants

  • Kim, Young-Kyun;Ahn, Kyo-Jin;Yun, Pil-Young;Kim, Minkyoung;Yang, Hong-So;Yi, Yang-Jin;Bae, Ji-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권4호
    • /
    • pp.161-167
    • /
    • 2013
  • Objectives: The objective of this study is compare the rate of marginal bone resorption around hydroxyapatite-coated implants given different loading times in order to evaluate their stability. Materials and Methods: The study was conducted retrospectively for one year, targeting 41 patients whose treatment areas were the posterior maxilla and the mandible. Osstem TS III HA (Osstem Implant Co., Busan, Korea) and Zimmer TSV-HA (Zimmer Dental, Carlsbad, CA, USA), which employ the new hydroxyapatite coating technique, were used. The patients were divided into two groups - immediate and delayed loading - and the bone level at the time of loading commencement and after one year of loading was measured using periapical radiography. Differences between the groups were evaluated using Mann-Whitney (${\alpha}$=0.05). Results: For all patients as a single group, the survival rate of the implants was 100%, and the mean marginal bone loss was $0.26{\pm}0.59mm$. In comparison of the differences by loading, mean marginal bone loss of $0.32{\pm}0.69mm$ was recorded for the immediate loading group whereas the delayed loading group had mean marginal bone loss of $0.16{\pm}0.42mm$. However, the difference was not significant (P>0.05). Conclusion: Within the limited observation period of one year, predictable survival rates can be expected when using immediately loaded hydroxyapatite-coated implants.

Retrospective clinical study on sinus bone graft and tapered-body implant placement

  • Kim, Jong-Hwa;Kim, Young-Kyun;Bae, Ji-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권2호
    • /
    • pp.77-84
    • /
    • 2013
  • Objectives: This study evaluated implant success rate, survival rate, marginal bone resorption of implants, and material resorption of sinus bone graft in cases wherein tapered body implants were installed. Materials and Methods: From September 2003 to January 2006, 20 patients from Seoul National University Bundong Hospital, with a mean age of 54.7 years, were considered. The mean follow-up period was 19 months. This study covered 50 implants; 14 implants were placed in the maxillary premolar area, and 36 in the maxillary molar area; 24 sinuses were included. Results: The success rate was 92%, and the survival rate was 96.0%. The mean amount of sinus augmentation was $12.35{\pm}3.27$ mm. The bone graft resorption rate one year after surgery was $0.97{\pm}0.84$ mm; that for the immediate implantation group was $0.91{\pm}0.86$ mm, and that for the delayed implantation group was $1.16{\pm}0.77$ mm. However, the difference was not statistically significant. The mean marginal bone resorption one year after restoration was $0.17{\pm}0.27$ mm (immediate group: $0.12{\pm}0.23$ mm; delayed group $0.40{\pm}0.33$ mm); statistically significant difference was observed between the two groups. Conclusion: Tapered body implant can be available in the maxillary posterior edentulous ridge which sinus bone graft is necessary.